Erman Kibritoglu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Erman Kibritoglu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Heba Yuksel
Department of Electrical and Electronics Engineering, Bogazici University, Istanbul 34342, Türkiye
4 shared publications - Abdullah Deniz Ertugrul
Department of Electrical and Electronics Engineering, Bogazici University, Istanbul 34342, Turkey
1 shared publication - Sinem Anil
Department of Physics, Bogazici University, Istanbul 34342, Turkey
1 shared publication
Latest Publications
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Non-contact dielectrophoretic forcing of particle-laden flow: Momentum transfer and flow modulation in a blood-mimicking suspension
Dielectrophoresis (DEP) provides a non-contact forcing mechanism for polarizable particles suspended in non-uniform electric fields. While DEP is commonly used for particle manipulation, trapping, and separation, its role as a distributed hydrodynamic forcing mechanism in particle-laden suspension flow remains less explored. This study investigates DEP-assisted flow modulation in a diluted glycerol–SiO2 suspension used as a controllable blood-mimicking particle-laden phantom. The fracture-healing context provides the transport motivation, whereas the central focus is the particle–fluid momentum-transfer mechanism. Three external coil geometries, Catenary, Lintearia, and Valeria, were evaluated at excitation currents of 0.50, 0.75, and 1.00 A, respectively. DEP-induced particle forcing was interpreted through a momentum-transfer framework, in which particle acceleration, particle–fluid slip, and viscous coupling contribute to macroscopic flow enhancement. The displaced volume was treated as an integral flow response relative to a nominal 100 ml no-DEP baseline. The results showed a clear coil- and current-dependent enhancement. At 0.75 A, displaced volumes of 120±4, 140±6, and 200±10 ml were obtained for the Catenary, Lintearia, and Valeria coils, respectively. The strongest response occurred for the Valeria coil at 1.00 A, reaching 215±9 ml. Model predictions agreed closely with experiments, with a root-mean square error (RMSE) of 5.14 ml, a mean absolute error (MAE) of 4.22 ml, a maximum absolute error (MaxAE) of 8.00 ml, and a Pearson correlation coefficient of r=0.995. These findings demonstrate that DEP can modulate particle-laden suspension flow through field-induced particle forcing and hydrodynamic momentum transfer.
- 1 September 2026
- Published by AIP Publishing in Physics of Fluids
- Vol. 38 (9)
Non-contact dielectrophoretic forcing of particle-laden flow: Momentum transfer and flow modulation in a blood-mimicking suspension
Dielectrophoresis (DEP) provides a non-contact forcing mechanism for polarizable particles suspended in non-uniform electric fields. While DEP is commonly used for particle manipulation, trapping, and separation, its role as a distributed hydrodynamic forcing mechanism in particle-laden suspension flow remains less explored. This study investigates DEP-assisted flow modulation in a diluted glycerol–SiO2 suspension used as a controllable blood-mimicking particle-laden phantom. The fracture-healing context provides the transport motivation, whereas the central focus is the particle–fluid momentum-transfer mechanism. Three external coil geometries, Catenary, Lintearia, and Valeria, were evaluated at excitation currents of 0.50, 0.75, and 1.00 A, respectively. DEP-induced particle forcing was interpreted through a momentum-transfer framework, in which particle acceleration, particle–fluid slip, and viscous coupling contribute to macroscopic flow enhancement. The displaced volume was treated as an integral flow response relative to a nominal 100 ml no-DEP baseline. The results showed a clear coil- and current-dependent enhancement. At 0.75 A, displaced volumes of 120±4, 140±6, and 200±10 ml were obtained for the Catenary, Lintearia, and Valeria coils, respectively. The strongest response occurred for the Valeria coil at 1.00 A, reaching 215±9 ml. Model predictions agreed closely with experiments, with a root-mean square error (RMSE) of 5.14 ml, a mean absolute error (MAE) of 4.22 ml, a maximum absolute error (MaxAE) of 8.00 ml, and a Pearson correlation coefficient of r=0.995. These findings demonstrate that DEP can modulate particle-laden suspension flow through field-induced particle forcing and hydrodynamic momentum transfer.
- 29 May 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 655
Accelerating bone fracture healing using magnetophoretic forces: A numerical analysis
- 29 May 2026
- Published by Elsevier in Journal of Magnetism and Magnetic Materials
- Vol. 655
Accelerating bone fracture healing using magnetophoretic forces: A numerical analysis
- Open Access
- 20 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 364
SAR-Based Thermal Assessment of Dielectrophoretic Pulsed Electromagnetic Stimulation in Tibia Fractures with Metallic Implants
Electromagnetic field-based stimulation has emerged as a promising noninvasive approach for enhancing bone fracture healing. Beyond conventional pulsed electromagnetic field (PEMF) therapies employing spatially uniform fields, dielectrophoretic-force-based (DEPF) stimulation exploits electromagnetic field non-uniformities to induce localized interactions to enhance fracture healing. However, the thermal behavior associated with DEPF-driven PEMF exposure in the presence of metallic orthopedic implants remains largely unexplored. In this study, the thermal response of tissue-like tibia phantoms with and without metallic implants is investigated using an integrated experimental and numerical framework. A custom-designed conical coil is employed to generate non-uniform DEPF excitation capable of affecting the fracture site. Surface temperature evolution is measured using infrared thermal imaging, while electromagnetic power absorption is quantified through specific absorption rate (SAR)-based thermal measurement coupled with a bio-heat formulation. Anatomically realistic tibia phantoms reconstructed from computed tomography data are fabricated via a 3D printer to represent clinically relevant fracture configurations. Experimental results show that the metallic implant exhibits a rapid temperature increase of approximately within the first few minutes of exposure, followed by thermal stabilization, corresponding to an effective absorbed power of inferred from the initial temperature slope. In contrast, the non-conductive resin phantom displays a temperature rise of only over the same interval, yielding . These findings demonstrate that implant-related eddy-current losses dominate localized heating under DEPF excitation, while tissue-like media remain weakly affected. This work provides SAR-based experimental evaluation of DEPF stimulation in implanted tibia fracture models, offering new insight into implant-induced electromagnetic heating and its implications for the safety and optimization of DEPF-based bone-healing therapies.- 20 March 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (3) , 364
Open AccessSAR-Based Thermal Assessment of Dielectrophoretic Pulsed Electromagnetic Stimulation in Tibia Fractures with Metallic Implants
Electromagnetic field-based stimulation has emerged as a promising noninvasive approach for enhancing bone fracture healing. Beyond conventional pulsed electromagnetic field (PEMF) therapies employing spatially uniform fields, dielectrophoretic-force-based (DEPF) stimulation exploits electromagnetic field non-uniformities to induce localized interactions to enhance fracture healing. However, the thermal behavior associated with DEPF-driven PEMF exposure in the presence of metallic orthopedic implants remains largely unexplored. In this study, the thermal response of tissue-like tibia phantoms with and without metallic implants is investigated using an integrated experimental and numerical framework. A custom-designed conical coil is employed to generate non-uniform DEPF excitation capable of affecting the fracture site. Surface temperature evolution is measured using infrared thermal imaging, while electromagnetic power absorption is quantified through specific absorption rate (SAR)-based thermal measurement coupled with a bio-heat formulation. Anatomically realistic tibia phantoms reconstructed from computed tomography data are fabricated via a 3D printer to represent clinically relevant fracture configurations. Experimental results show that the metallic implant exhibits a rapid temperature increase of approximately within the first few minutes of exposure, followed by thermal stabilization, corresponding to an effective absorbed power of inferred from the initial temperature slope. In contrast, the non-conductive resin phantom displays a temperature rise of only over the same interval, yielding . These findings demonstrate that implant-related eddy-current losses dominate localized heating under DEPF excitation, while tissue-like media remain weakly affected. This work provides SAR-based experimental evaluation of DEPF stimulation in implanted tibia fracture models, offering new insight into implant-induced electromagnetic heating and its implications for the safety and optimization of DEPF-based bone-healing therapies. - 24 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110213
Numerical analysis of coil designs to expedite fracture healing using dielectrophoresis with S method
- 24 April 2025
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 192 (Pt A) , 110213
Numerical analysis of coil designs to expedite fracture healing using dielectrophoresis with S method