ABArkadip Basak

Arkadip Basak

*This is an algorithmically generated author record based on publicly available information.

Arkadip Basak has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-term variability of Cygnus X−1. IX. A spectral-timing comparison of Cygnus X−1 and MAXI J1820+070 in the hard state

    by Arkadip Basak, Phil Uttley, Niek Bollemeijer, Matteo Bachetti, Arash Bahramian, Victoria Grinberg, Erin Kara, Eleonora V Lai, Thomas J Maccarone, Barbara De Marco, et al.

    Cygnus X−1 is a persistent, high-mass black hole X-ray binary (BHXRB) which in the hard state shows many similar properties to transient BHXRBs, along with intriguing differences, such as the lack of quasi-periodic oscillations. Here, we compare for the first time the detailed spectral-timing properties of Cyg X−1 with a transient BHXRB, MAXI J1820+070, combining data from XMM–Newton and NICER (Neutron Star Interior Composition Explorer) with contemporaneous INTEGRAL (International Gamma-Ray Astrophysics Laboratory) data to study the power spectra, rms spectra, and time lags over a broad 0.5–200 keV range. We select bright hard state MAXI J1820+070 data with similar power-spectral shapes to the Cyg X−1 data, to compare the source behaviours while accounting for the evolution of spectral-timing properties, notably the lags, through the hard state. Cyg X−1 shows no evidence for soft lags in the 1–10 Hz frequency range where they are clearly detected for MAXI J1820+070. Furthermore, the low-frequency hard lags and rms spectra evolve much more strongly during the hard state of Cyg X−1 than for MAXI J1820+070. We argue that these differences cannot be explained by the different black hole masses of these systems, but may be related to their different accretion rates and corresponding locations on the hardness–intensity diagram. We conjecture that there is a significant luminosity-dependence of coronal geometry in the hard state of BHXRBs, rather than an intrinsic difference between Cyg X−1 and transient BHXRBs. This possibility has also been suggested to explain a common time-lag feature that appears in the hard intermediate states of Cyg X−1 and transient BHXRBs.


  • Imaging effects due to pixel distortions in CdZnTe detectors—results from the HREXI Calibration Facility

    by Arkadip Basak, Branden Allen, Jaesub Hong, Daniel P. Violette, Jonathan Grindlay

    ProtoEXIST2 (P2) was a prototype imaging x-ray detector plane developed for wide-field time-domain astrophysics (TDA) in the 5 to 200 keV energy band. It was composed of an 8 × 8 array of 5 mm thick, 2 cm × 2 cm pixelated (32 × 32) CdZnTe (CZT) detectors with a 0.6-mm pitch that utilize the NuSTAR ASIC (NuASIC) for readout. During the initial detector development process leading up to postflight examination of the entire detector plane, distortions in expected pixel positions and shapes were observed in a significant fraction of the detectors. The High Resolution Energetic x-ray Imager (HREXI) calibration facility (HCF) was designed and commissioned to improve upon these early experiments and to rapidly map out and characterize pixel nonuniformities and defects within CZT detector planes at resolutions down to 50 μm. Using this facility, the subpixel level detector response of P2 was measured at 100 μm5 resolution and analyzed to extract and evaluate the area and profile of individual pixels, their morphology across the entire P2 detector plane for comparison with previous measurements and to provide additional characterization. In this article, we evaluate the imaging performance of a coded-aperture telescope using the observed pixel morphology for P2 detectors. This investigation will serve as an initial guide for detector selection in the development of HREXI detector planes, for the future implementation of the 4pi X-Ray Imaging Observatory (4piXIO)6 mission, which aims to provide simultaneous and continuous imaging of the full sky (4π sr) in the 3 to 200 keV energy band with ≃2 arcmin angular resolution and ≃10 arcsec source localization, as well as other, future coded-aperture instruments.


  • Top Cited Papers
    Open Access

    An Empirical Background Model for the NICER X-Ray Timing Instrument

    by Ronald A. Remillard, Michael Loewenstein, James F. Steiner, Gregory Y. Prigozhin, Beverly LaMarr, Teruaki Enoto, Keith C. Gendreau, Zaven Arzoumanian, Craig Markwardt, Arkadip Basak, et al.

    Neutron Star Interior Composition Explorer has a comparatively low background rate, but it is highly variable, and its spectrum must be predicted using measurements unaffected by the science target. We describe an empirical, three-parameter model based on observations of seven pointing directions that are void of detectable sources. Two model parameters track different types of background events, while the third is used to predict a low-energy excess tied to observations conducted in sunlight. An examination of 3556 good time intervals (GTIs), averaging 570 s, yields a median rate (0.4–12 keV; 50 detectors) of 0.87 c s−1, but in 5% (1%) of cases, the rate exceeds 10 (300) c s−1. Model residuals persist at 20%–30% of the initial rate for the brightest GTIs, implying one or more missing model parameters. Filtering criteria are given to flag GTIs likely to have unsatisfactory background predictions. With such filtering, we estimate a detection limit, 1.20 c s−1 (3σ, single GTI) at 0.4–12 keV, equivalent to 3.6 × 10−12 erg cm−2 s−1 for a Crab-like spectrum. The corresponding limit for soft X-ray sources is 0.51 c s−1 at 0.3–2.0 keV, or 4.3 × 10−13 erg cm−2 s−1 for a 100 eV blackbody. These limits would be four times lower if exploratory GTIs accumulate 10 ks of data after filtering at the level prescribed for faint sources. Such filtering selects background GTIs 85% of the time. An application of the model to a 1 s timescale makes it possible to distinguish source flares from possible surges in the background.


  • HREXI calibration facility: mapping out subpixel-level responses from high-resolution cadmium zinc telluride imaging x-ray detectors

    by Arkadip Basak, Branden Allen, Jaesub Hong, Daniel P. Violette, Jonathan Grindlay

    The High-Resolution Energetic X-ray Imager (HREXI) cadmium zinc telluride (CZT) detector development program at Harvard is aimed at developing tiled arrays of finely pixelated CZT detectors for use in wide-field coded aperture 3 to 200 keV x-ray telescopes. A pixel size of ∼600 μm has already been achieved in the ProtoEXIST2 (P2) detector plane with CZT readout by the NuSTAR application-specific integrated circuits. This paves the way for even smaller than 300-μm pixels in the next-generation HREXI detectors. We describe a new HREXI calibration facility (HCF) that enables a high-resolution subpixel-level (100 μm) two-dimensional (2D) scan of a 256-cm2 tiled array of 2 × 2 cm2 CZT detectors illuminated by a bright x-ray AmpTek Mini-X tube source at timescales of around a day. HCF is a significant improvement from the previous apparatus used for scanning these detectors, which took ∼3 weeks to complete a one-dimensional (1D) scan of a similar detector plane. Moreover, HCF has the capability to scan a large tiled array of CZT detectors (32 × 32 cm2) at 100-μm resolution in the 10- to 50-keV energy range, which was not possible previously. We describe the design, construction, and implementation of HCF for the calibration of the P2 detector plane.