Ricardo Jochann Franceschi Bortolini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Ricardo Jochann Franceschi Bortolini has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Leandro Michels
Universidade Federal de Santa Maria
5 shared publications - Lucas Vizzotto Bellinaso
Federal University of Santa Maria
3 shared publications - Anderson Luis Do Nascimento Severo
Power Electronics and Control Group, Federal University of Santa Maria, Santa Maria, Rio Grande do Sul, Brazil
2 shared publications - Fernanda de Morais Carnielutti
Federal University of Santa Maria, Santa Maria, Brazil
2 shared publications - Lucas Bisêlo Piton
WEG S.A., Jaragu do Sul, Brazil
2 shared publications - Luiz Fernando Rissotto Menegazzo
Federal University of Santa Maria
2 shared publications
Latest Publications
- 24 July 2026
- Published by Elsevier in Solar Energy
- Vol. 316
Methodology for determining inverter efficiency curves for photovoltaic power and energy simulation
- 24 July 2026
- Published by Elsevier in Solar Energy
- Vol. 316
Methodology for determining inverter efficiency curves for photovoltaic power and energy simulation
- Open Access
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 74900-74916
Toward Fully-Automated Hardware-in-the-Loop Grid Code Compliance Certification of Inverter-Based Distributed Energy Resources
Inverter-based Distributed Energy Resources (DERs) third-party compliance testing has been widely required by most grid codes to guarantee interoperability with the electrical power system. However, most grid code certification procedures only accept the evaluation of the whole product under full-power environments. For high-power equipment, this procedure is costly, time-intensive, and complex to be performed. Due to this, many efforts have been made to make possible using Controller Hardware-in-the-Loop (CHIL) testing for validation of the inverter firmware from early product development through final certification, facilitating the identification of early issues and reducing debugging time and costs. On the other hand, since most CHIL tests are performed in environments distinct from full power laboratory testing, both approaches often follow different procedures and do not take into account the same metrics, which can result in low fidelity between CHIL and power laboratory results. In order to make possible to use CHIL for compliance testing, model validation has to be performed, guaranteeing that model fidelity is satisfactory. In this context, this paper presents a comprehensive methodology to validate CHIL models and to clearly identify, measure, and reduce differences between the results obtained with CHIL and with power laboratory testing environments. The methodology is based on standardized quantitative test procedures applied to both CHIL and power laboratory testing. The proposed methodology is extensively validated through experimental results carried out on a commercial single- phase photovoltaic inverter. Results demonstrate the validity of CHIL testing methodology and propose an alternative method for grid code compliance testing and certification.
- 28 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 74900-74916
Open AccessToward Fully-Automated Hardware-in-the-Loop Grid Code Compliance Certification of Inverter-Based Distributed Energy Resources
Inverter-based Distributed Energy Resources (DERs) third-party compliance testing has been widely required by most grid codes to guarantee interoperability with the electrical power system. However, most grid code certification procedures only accept the evaluation of the whole product under full-power environments. For high-power equipment, this procedure is costly, time-intensive, and complex to be performed. Due to this, many efforts have been made to make possible using Controller Hardware-in-the-Loop (CHIL) testing for validation of the inverter firmware from early product development through final certification, facilitating the identification of early issues and reducing debugging time and costs. On the other hand, since most CHIL tests are performed in environments distinct from full power laboratory testing, both approaches often follow different procedures and do not take into account the same metrics, which can result in low fidelity between CHIL and power laboratory results. In order to make possible to use CHIL for compliance testing, model validation has to be performed, guaranteeing that model fidelity is satisfactory. In this context, this paper presents a comprehensive methodology to validate CHIL models and to clearly identify, measure, and reduce differences between the results obtained with CHIL and with power laboratory testing environments. The methodology is based on standardized quantitative test procedures applied to both CHIL and power laboratory testing. The proposed methodology is extensively validated through experimental results carried out on a commercial single- phase photovoltaic inverter. Results demonstrate the validity of CHIL testing methodology and propose an alternative method for grid code compliance testing and certification.
- Open Access
- 25 October 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29, e202443
Unified Platform for Automated Tests of Inverter-Based Resources with Hardware-in-the-loop
Testing of inverter-based resources (IBRs) faces challenges in establishing standardized procedures across all product development stages. Most of the testing approaches use Hardware-in-the-Loop (HIL) during the early stages independently from the final product testing, which can lead to discrepant results. To solve these issues, this paper proposes a unified platform for automatically testing IBRs. It can be used during all product development stages, from pure simulation to Controller Hardware-in-the-Loop (CHIL) and finally on the complete commercial product, ensuring uniform test procedures with different test setups. A case study describing compliance tests of grid-connection codes of photovoltaic (PV) inverters are presented to demonstrate the proposed approach. Experimental tests were performed in accordance to Brazilian grid-connection codes in an ISO/IEC 17025 accredited laboratory. The results obtained with the proposed platform in CHIL and full-hardware showed high similarity with the ones obtained with the accredited laboratory, validating the proposed approach. In addition, the platform can be used to perform tests not specified in standards and to verify the performance of IBRs in operating conditions that are often difficult to be tested in laboratory. Ensuring consistent test procedures, the platform facilitates comparable results along all the testing stages, reducing the product development cycle.
- 25 October 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29, e202443
Open AccessUnified Platform for Automated Tests of Inverter-Based Resources with Hardware-in-the-loop
Testing of inverter-based resources (IBRs) faces challenges in establishing standardized procedures across all product development stages. Most of the testing approaches use Hardware-in-the-Loop (HIL) during the early stages independently from the final product testing, which can lead to discrepant results. To solve these issues, this paper proposes a unified platform for automatically testing IBRs. It can be used during all product development stages, from pure simulation to Controller Hardware-in-the-Loop (CHIL) and finally on the complete commercial product, ensuring uniform test procedures with different test setups. A case study describing compliance tests of grid-connection codes of photovoltaic (PV) inverters are presented to demonstrate the proposed approach. Experimental tests were performed in accordance to Brazilian grid-connection codes in an ISO/IEC 17025 accredited laboratory. The results obtained with the proposed platform in CHIL and full-hardware showed high similarity with the ones obtained with the accredited laboratory, validating the proposed approach. In addition, the platform can be used to perform tests not specified in standards and to verify the performance of IBRs in operating conditions that are often difficult to be tested in laboratory. Ensuring consistent test procedures, the platform facilitates comparable results along all the testing stages, reducing the product development cycle.
- Open Access
- 16 July 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29, e202419
Methodology to Define an Overall Efficiency of Photovoltaic Inverters Considering Static and Dynamic Tests
Efficiency indices for inverters have been developed with the increasing adoption of photovoltaic (PV) systems. The European and Californian efficiencies are widely recognized, focusing on static inverter operation. Standards such as EN50530 and IEC 62891 introduced dynamic efficiency tests considering irradiance variations, but without a methodology to weigh the efficiencies within a single index. To address this gap, our study proposes a methodology to define an overall efficiency considering both static and dynamic inverter operation. Irradiance data with sub-minute sampling is classified into irradiance and irradiance derivative ranges. Then, weights for static and dynamic efficiency tests are obtained, and less significant ones are discarded. The results were applied to three PV inverters tested in the laboratory. By eliminating the less significant tests, the number of dynamic tests was reduced from 30 to 10. In two of the inverters, the inclusion of dynamic tests resulted in a 2\% reduction in overall efficiency compared to the static. An overall efficiency index is relevant for better comparing different PV inverters, especially when considering dynamic behaviors. This index may be significant for the PV market, governmental energy efficiency programs, and inverter manufacturers, providing guidelines to enhance the efficiency of their products.
- 16 July 2024
- Published by Associacao Brasileira de Eletronica de Potencia SOBRAEP in Eletrônica de Potência
- Vol. 29, e202419
Open AccessMethodology to Define an Overall Efficiency of Photovoltaic Inverters Considering Static and Dynamic Tests
Efficiency indices for inverters have been developed with the increasing adoption of photovoltaic (PV) systems. The European and Californian efficiencies are widely recognized, focusing on static inverter operation. Standards such as EN50530 and IEC 62891 introduced dynamic efficiency tests considering irradiance variations, but without a methodology to weigh the efficiencies within a single index. To address this gap, our study proposes a methodology to define an overall efficiency considering both static and dynamic inverter operation. Irradiance data with sub-minute sampling is classified into irradiance and irradiance derivative ranges. Then, weights for static and dynamic efficiency tests are obtained, and less significant ones are discarded. The results were applied to three PV inverters tested in the laboratory. By eliminating the less significant tests, the number of dynamic tests was reduced from 30 to 10. In two of the inverters, the inclusion of dynamic tests resulted in a 2\% reduction in overall efficiency compared to the static. An overall efficiency index is relevant for better comparing different PV inverters, especially when considering dynamic behaviors. This index may be significant for the PV market, governmental energy efficiency programs, and inverter manufacturers, providing guidelines to enhance the efficiency of their products.
- 17 February 2022
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (6) , 7118-7136
Management of operation and maintenance practices in photovoltaic plants: Key performance indicators
- 17 February 2022
- Published by Wiley in International Journal of Energy Research
- Vol. 46 (6) , 7118-7136
Management of operation and maintenance practices in photovoltaic plants: Key performance indicators