Phaneendra K. Duddempudi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Phaneendra K. Duddempudi has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Brett I. Bell
Department of Family and Social Medicine, Albert Einstein College of Medicine, Bronx, New York
7 shared publications - Chandan Guha
Department of Radiation Oncology, Albert Einstein College of Medicine, Bronx, NY 10461, USA
7 shared publications - Christian Velten
Montefiore Medical Center, Department of Radiation Oncology, Bronx, NY, USA; Albert Einstein College of Medicine, Institute for Onco-Physics, Bronx, NY, USA
7 shared publications - Jeb English
Department of Radiation Oncology, Montefiore Medical Center, Bronx, New York
7 shared publications - Justin Vercellino
Albert Einstein College of Medicine
7 shared publications - Kathryn E. Tanaka
Department of Pathology, Albert Einstein College of Medicine, Bronx, New York
7 shared publications
Latest Publications
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessSupplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Supplementary Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
- Open Access
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Data from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects.Significance:Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 31 March 2023
- Published by American Association for Cancer Research (AACR)
Open AccessData from Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects.Significance:Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 3 August 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (15) , 2678-2691
Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects. Significance: Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- 3 August 2022
- Published by American Association for Cancer Research (AACR) in Cancer Research
- Vol. 82 (15) , 2678-2691
Orthovoltage X-Rays Exhibit Increased Efficacy Compared with γ-Rays in Preclinical Irradiation
Radionuclide irradiators (137Cs and 60Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. Amidst concerns of radiological terrorism, there are institutional initiatives to replace radionuclide sources with lower energy X-ray sources. As researchers transition, questions remain regarding whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays because different energies may induce divergent biological effects. We therefore sought to compare the effects of orthovoltage X-rays with 1-mm Cu or Thoraeus filtration and 137Cs γ-rays using mouse models of acute radiation syndrome. Following whole-body irradiation, 30-day overall survival was assessed, and the lethal dose to provoke 50% mortality within 30-days (LD50) was calculated by logistic regression. LD50 doses were 6.7 Gy, 7.4 Gy, and 8.1 Gy with 1-mm Cu-filtered X-rays, Thoraeus-filtered X-rays, and 137Cs γ-rays, respectively. Comparison of bone marrow, spleen, and intestinal tissue from mice irradiated with equivalent doses indicated that injury was most severe with 1-mm Cu-filtered X-rays, which resulted in the greatest reduction in bone marrow cellularity, hematopoietic stem and progenitor populations, intestinal crypts, and OLFM4+ intestinal stem cells. Thoraeus-filtered X-rays provoked an intermediate phenotype, with 137Cs showing the least damage. This study reveals a dichotomy between physical dose and biological effect as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose reduction to achieve comparable biological effects. Significance: Understanding the significance of physical dose delivered using energetically different methods of radiation treatment will aid the transition from radionuclide γ-irradiators to orthovoltage X-irradiators.
- Open Access
Increased Relative Biological Effectiveness of Orthovoltage X-rays Compared to γ-rays in Preclinical Irradiation
Purpose: Radionuclide irradiators ( 137 Cs and 60 Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. There are institutional initiatives to replace radionuclide sources with lower-energy X-ray sources amidst concerns of radiological terrorism. As researchers transition, there are questions whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays, since different energy may cause different biological effects. We, therefore, sought to compare the effects of orthovoltage X-rays and 137 Cs γ-rays using mouse models of acute radiation syndrome. Experimental Design: 137 Cs γ-rays were compared with Orthovoltage X-rays, generated at 300 kVp, 10 mA with 1 mm Cu or Thoraeus filtration. We assessed 30-day overall survival following whole-body irradiation and calculated LD 50 by logistic regression. Comparing equivalent doses delivered with different average energies (Ē), we assessed bone marrow, spleen, and intestinal histology and flow cytometry. Results: The LD 50 doses are 6.7 Gy, 7.4 Gy and 8.1 Gy with 1 mm Cu filtered (Ē=120 keV), and Thoraeus filtered X-rays (Ē=160 keV), and 137 Cs (E=662 keV), respectively. At constant dose, hematopoietic injury was most severe with 1 mm Cu filtered X-rays with the greatest reduction in bone marrow cellularity, stem and progenitor populations, and intestinal crypts and OLFM4 + intestinal stem cells. Thoraeus filtered X-rays provoked an intermediate phenotype, with 137 Cs showing the least damage. Conclusions: Our study reveals a dichotomy between physical dose and biological effect relevant as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose-reduction to achieve comparable biological effects. Statement of Translational Relevance: Radiation is used in translational studies in fields ranging from hematopoiesis and stem cell biology to cancer radiotherapy, with 137 Cs and 60 Co radionuclide sources serving as the most common irradiators. Due to the threat of radiological terrorism using stolen radionuclides, there are institutional initiatives to replace these sources with orthovoltage X-ray irradiators. Yet, as shown in this study, the biological effects of radiation are highly dependent on radiation energy. Lower energy orthovoltage X-rays are absorbed differently than higher energy radionuclide γ-rays, provoking more severe hematopoietic, immunologic, and gastrointestinal radiation injury. Thus, an identical physical dose delivered with beams of differing energy does not produce the same biologic effect. As researchers transition between these sources, it is critical that we appreciate that radiation doses are not interchangeable between them. Understanding the significance of physical dose delivered using different methods will allow us to contextualize past results with future studies.
Open AccessIncreased Relative Biological Effectiveness of Orthovoltage X-rays Compared to γ-rays in Preclinical Irradiation
Purpose: Radionuclide irradiators ( 137 Cs and 60 Co) are commonly used in preclinical studies ranging from cancer therapy to stem cell biology. There are institutional initiatives to replace radionuclide sources with lower-energy X-ray sources amidst concerns of radiological terrorism. As researchers transition, there are questions whether the biological effects of γ-rays may be recapitulated with orthovoltage X-rays, since different energy may cause different biological effects. We, therefore, sought to compare the effects of orthovoltage X-rays and 137 Cs γ-rays using mouse models of acute radiation syndrome. Experimental Design: 137 Cs γ-rays were compared with Orthovoltage X-rays, generated at 300 kVp, 10 mA with 1 mm Cu or Thoraeus filtration. We assessed 30-day overall survival following whole-body irradiation and calculated LD 50 by logistic regression. Comparing equivalent doses delivered with different average energies (Ē), we assessed bone marrow, spleen, and intestinal histology and flow cytometry. Results: The LD 50 doses are 6.7 Gy, 7.4 Gy and 8.1 Gy with 1 mm Cu filtered (Ē=120 keV), and Thoraeus filtered X-rays (Ē=160 keV), and 137 Cs (E=662 keV), respectively. At constant dose, hematopoietic injury was most severe with 1 mm Cu filtered X-rays with the greatest reduction in bone marrow cellularity, stem and progenitor populations, and intestinal crypts and OLFM4 + intestinal stem cells. Thoraeus filtered X-rays provoked an intermediate phenotype, with 137 Cs showing the least damage. Conclusions: Our study reveals a dichotomy between physical dose and biological effect relevant as researchers transition to orthovoltage X-rays. With decreasing energy, there is increasing hematopoietic and intestinal injury, necessitating dose-reduction to achieve comparable biological effects. Statement of Translational Relevance: Radiation is used in translational studies in fields ranging from hematopoiesis and stem cell biology to cancer radiotherapy, with 137 Cs and 60 Co radionuclide sources serving as the most common irradiators. Due to the threat of radiological terrorism using stolen radionuclides, there are institutional initiatives to replace these sources with orthovoltage X-ray irradiators. Yet, as shown in this study, the biological effects of radiation are highly dependent on radiation energy. Lower energy orthovoltage X-rays are absorbed differently than higher energy radionuclide γ-rays, provoking more severe hematopoietic, immunologic, and gastrointestinal radiation injury. Thus, an identical physical dose delivered with beams of differing energy does not produce the same biologic effect. As researchers transition between these sources, it is critical that we appreciate that radiation doses are not interchangeable between them. Understanding the significance of physical dose delivered using different methods will allow us to contextualize past results with future studies.
- Open Access
- 1 November 2020
- Published by BMJ in Journal for ImmunoTherapy of Cancer
- Vol. 8 (Suppl 3) , A374.2-A375
623 Immuno-STATs: Leveraging protein engineering to expand and track antigen-specific T cells in vivo
Background Immunotherapies are highly promising and effective strategies for the treatment of cancer; however, continuing challenges persist, including 1) untargeted global immune modulation, resulting in serious side effects; 2) lack of therapeutics capable of in vivo expansion of tumor-specific T cells; 3) inability to visualize in vivo tumor-specific T cell responses; and 4) lack of flexible platforms to rapidly and efficiently explore new therapeutic strategies and immune-escape mechanisms. To address these challenges, we developed a novel class of precision biologics to treat cancer, autoimmune diseases and infectious diseases. We describe a modular platform constructed around an Fc-based covalent pMHC dimer, referred to as synTac (artificial synapse for T cell activation; also termed Immuno-STATs for Selective Targeting and Alteration of T cells), which selectively delivers different cargoes, including costimulatory, coinhibitory or cytokine signals and other modalities to primary T cells of defined specificity. The inherent modularity supports broad applications. Changing the encoded peptide enables targeting of different T cell specificities to address different diseases, while altering the cargo allows for evaluation of different co-modulatory mechanisms or the delivery of mechanistically informative probes. Methods Sortase A-mediated enzymatic coupling supported site-specific and stoichiometric installation of positron emission tomography (PET)-active radiolabels on synTacs to visualize the in vivo localization of antigen-specific T cells. The NSG humanized mouse model allowed for the evaluation of synTacs/Immuno-STATs to drive the in vivo antigen-specific expansion of human CD8 T cells. Results Using radiolabeled synTacs/Immuno-STATs loaded with the appropriate peptides, we employed positron emission tomography to localize human papillomavirus (HPV16)-specific CD8 T cells to implanted HPV16-positive tumors in mice, as well as influenza A virus (IAV)-specific CD8 T cells in the lungs of IAV-infected mice. In vivo administration of HIV- and CMV-specific synTacs/Immuno-STATs to immunodeficient mice intrasplenically engrafted with human donor PBMCs resulted in the marked and selective expansion of HIV-specific and CMV-specific human CD8 T cells populating their spleens, respectively. Conclusions We demonstrate the remarkable flexibility of the synTacs/Immuno-STAT platform for addressing a broad range of applications, including the first report of the in vivo imaging of antigen-specific CD8 T cell populations and in vivo antigen-selective expansion of human CD8 T cells. These results suggest that, in addition to broad therapeutic applications, synTac/Immuno-STATs may provide prognostic/diagnostic information. Most notably, these results demonstrate the presence of synTacs/Immuno-STAT biologics in the tumor or infected tissues where they can elicit T cell restimulation and expansion necessary for target killing and enhanced therapeutic efficacy.
- 1 November 2020
- Published by BMJ in Journal for ImmunoTherapy of Cancer
- Vol. 8 (Suppl 3) , A374.2-A375
Open Access623 Immuno-STATs: Leveraging protein engineering to expand and track antigen-specific T cells in vivo
Background Immunotherapies are highly promising and effective strategies for the treatment of cancer; however, continuing challenges persist, including 1) untargeted global immune modulation, resulting in serious side effects; 2) lack of therapeutics capable of in vivo expansion of tumor-specific T cells; 3) inability to visualize in vivo tumor-specific T cell responses; and 4) lack of flexible platforms to rapidly and efficiently explore new therapeutic strategies and immune-escape mechanisms. To address these challenges, we developed a novel class of precision biologics to treat cancer, autoimmune diseases and infectious diseases. We describe a modular platform constructed around an Fc-based covalent pMHC dimer, referred to as synTac (artificial synapse for T cell activation; also termed Immuno-STATs for Selective Targeting and Alteration of T cells), which selectively delivers different cargoes, including costimulatory, coinhibitory or cytokine signals and other modalities to primary T cells of defined specificity. The inherent modularity supports broad applications. Changing the encoded peptide enables targeting of different T cell specificities to address different diseases, while altering the cargo allows for evaluation of different co-modulatory mechanisms or the delivery of mechanistically informative probes. Methods Sortase A-mediated enzymatic coupling supported site-specific and stoichiometric installation of positron emission tomography (PET)-active radiolabels on synTacs to visualize the in vivo localization of antigen-specific T cells. The NSG humanized mouse model allowed for the evaluation of synTacs/Immuno-STATs to drive the in vivo antigen-specific expansion of human CD8 T cells. Results Using radiolabeled synTacs/Immuno-STATs loaded with the appropriate peptides, we employed positron emission tomography to localize human papillomavirus (HPV16)-specific CD8 T cells to implanted HPV16-positive tumors in mice, as well as influenza A virus (IAV)-specific CD8 T cells in the lungs of IAV-infected mice. In vivo administration of HIV- and CMV-specific synTacs/Immuno-STATs to immunodeficient mice intrasplenically engrafted with human donor PBMCs resulted in the marked and selective expansion of HIV-specific and CMV-specific human CD8 T cells populating their spleens, respectively. Conclusions We demonstrate the remarkable flexibility of the synTacs/Immuno-STAT platform for addressing a broad range of applications, including the first report of the in vivo imaging of antigen-specific CD8 T cell populations and in vivo antigen-selective expansion of human CD8 T cells. These results suggest that, in addition to broad therapeutic applications, synTac/Immuno-STATs may provide prognostic/diagnostic information. Most notably, these results demonstrate the presence of synTacs/Immuno-STAT biologics in the tumor or infected tissues where they can elicit T cell restimulation and expansion necessary for target killing and enhanced therapeutic efficacy.