Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Wenhe He has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • LSCA: Low-Latency Scalable Convolution Accelerator

    by Weipu Zhu, Tao Lu, Huiting Li, Wenhe He, Qingnian Li

  • Ultrasound-Mediated Plasmid Delivery by Stable Oscillation of Linear Array Microbubbles in Microfluidic Channels

    by Guangyong Huang, Cuimin Sun, Xiangfu Wei, Shengchang Tang, Shixiong Wu, Wenhe He, Peng Dai, Yongchao Cai, Hui You

    Intracellular delivery is among the biotechnological methods used for studying cell therapy, drug delivery, and biomanufacturing. Currently, ultrasound-mediated intracellular delivery with microfluidics has the advantage of being controllable and efficient. However, the conventional method of sonoporation through the generation of microbubbles in cavities faces challenges in maintaining optimal microbubble size and shape. In this paper, we present a device based on linear array microbubbles to induce acoustic streaming, which can regulate cell membrane permeability in a stable and controllable method. To solve these challenges,high-resolution photosensitive resin 3D printing is utilised to fabricate vertical array T-junction structures with significant aspect ratios for the generation of microbubbles. When microbubble volume changes due to environmental influences, the size of the microbubble cap remains constant due to the constraints of microchannel width, thus reducing the adverse effects of microbubble size variations and ensuring stable oscillation. Then cells are captured and trapped on the surface of microbubbles under the combined effects of oscillating microbubble-induced secondary acoustic radiation force and acoustic streaming, ultimately leading to alterations in the permeability of the cell membrane under shear stress. The experiments show that the delivery efficiency of 293T cells is 93.2 ± 2.3% while maintaining high cell viability at a driving voltage of 30 V. Furthermore, we have successfully delivered a plasmid encoding green fluorescent protein (8.2kbp) to the cells, and the experimental results show a transfection efficiency of 30.7 ± 2.8%. This novel acoustofluidic method achieves rapid, reusable intracellular delivery, and may have utility in microfluidic chip applications.


  • Open Access

    A Novel Overlapping ME Peaks Decomposition Algorithm Based on Iterative Derivative Sharpening

    by Wenhe He, Hui You, Zihao Lu, Yaping Liu, Yuanfen Chen, Ying Liu, Cuimin Sun

    In Microchip electrophoresis (ME) signals, multiple sub-peaks low resolution overlapping peaks seriously interfere with the measurement of peak parameters. However, existing peak analysis methods either address the problem of two sub-peaks overlapping peaks or set peak parameters empirically. In this study, an automatic overlapping peaks decomposition algorithm based on signal smoothing, iterative sharpening, and peak fitting is proposed. First, the Savitzky-Golay (SG) filter is used for smoothing ME signals because it outperforms other smoothing methods in peak retention ability, smoothness, and preservation of the high-frequency information content of the signal. Second, an iterative peaks sharpening strategy is proposed based on the principle of the even-order derivative method. Finally, overlapping peak analysis methods based on swarm intelligence algorithms, gradient algorithms, and simplex algorithm, respectively, are proposed. For the swarm intelligence based fitting algorithms, the fitting errors of ME signals using the proposed peak sharpening strategy are reduced by 13.5%, 23.7%, and 40.0% on average, respectively.


  • Open Access

    A Novel Unresolved Peaks Analysis Algorithm for ME Signal Detection Based on Improved SMA

    by Wenhe He, Yaping Liu, Jianjiao Wang, Yuanfen Chen, Lin Lin, Zhipeng Qin, Cuimin Sun, Hui You, Ying Liu

    Microchip electrophoresis (ME) is an ion detection system with low cost and portability, which is suitable for online analysis of environmental samples. However, the unresolved peaks in the detection signal of complex samples seriously affect the measurement accuracy of sample concentration. In this paper, an efficient unresolved peaks analysis algorithm is proposed, which is based on the Sigmoidal membership function, Lévy flight, and Slime Mould Algorithm (SLSMA). First, the hyperbolic tangent function in the original Slime Mould Algorithm (SMA) is replaced by the Sigmoidal membership function to enhance the global optimization capability. Second, we use the Lévy flight sequences to further enhance the convergence speed of the SMA algorithm. Then, the performance of SLSMA is tested using synthetic peaks with different resolutions and noise levels. Finally, ME peaks are used to further validate the application of the proposed algorithm. The results show that the proposed algorithm has higher computational efficiency and can be used for the analysis of ME peaks.


  • Open Access

    A Novel Symmetrical Peak Fitting Method Based on Improved WOA Algorithm for the Analysis of Microchip Electrophoresis Signals

    by Wenhe He, Jianjiao Wang, Yaping Liu, Zhipeng Qin, Cuimin Sun, Hui You, Xiangfu Wei, Ying Liu

    The problem of overlapping peaks has been a challenge in microchip electrophoresis (ME) signal analysis. However, traditional peak fitting algorithms have difficulty analyzing overlapping peaks due to the high dependence on the starting point. In this study, we propose a symmetrical peak fitting method named the tent-mapped whale optimization algorithm and Levenberg–Marquardt (TWOALM), which combines a whale optimization algorithm (WOA) improved by one of the most commonly used chaotic maps, the tent map and the Levenberg–Marquardt (LM) algorithm. Specifically, we first derive the fitted model for the overlapping peaks, showing that it is separable nonlinear least squares, significantly reducing the number of parameters to be optimized. Second, we integrate the tent map into the WOA, which improves the convergence speed of the peak fitting algorithm. Finally, we propose an efficient peak-fitting algorithm that combines the improved WOA and LM. The advantage of the proposed algorithm is that it is significantly faster than WOA and significantly more accurate than the LM algorithm. The results of fitting the synthetic peaks and ME signals showed that the combination of the chaotic map-based WOA algorithm and the LM algorithm can significantly improve the peak fitting performance and provide an effective solution for the analysis of overlapping peaks.


  • Open Access

    A Novel Planar Grounded Capacitively Coupled Contactless Conductivity Detector for Microchip Electrophoresis

    by Jianjiao Wang, Yaping Liu, Wenhe He, Yuanfen Chen, Hui You

    In the microchip electrophoresis with capacitively coupled contactless conductivity detection, the stray capacitance of the detector causes high background noise, which seriously affects the sensitivity and stability of the detection system. To reduce the effect, a novel design of planar grounded capacitively coupled contactless conductivity detector (PG-C4D) based on printed circuit board (PCB) is proposed. The entire circuit plane except the sensing electrodes is covered by the ground electrode, greatly reducing the stray capacitance. The efficacy of the design has been verified by the electrical field simulation and the electrophoresis detection experiments of inorganic ions. The baseline intensity of the PG-C4D was less than 1/6 of that of the traditional C4D. The PG-C4D with the new design also demonstrated a good repeatability of migration time, peak area, and peak height (n = 5, relative standard deviation, RSD ≤ 0.3%, 3%, and 4%, respectively), and good linear coefficients within the range of 0.05–0.75 mM (R2 ≥ 0.986). The detection sensitivity of K+, Na+, and Li+ reached 0.05, 0.1, and 0.1 mM respectively. Those results prove that the new design is an effective and economical approach which can improve sensitivity and repeatability of a PCB based PG-C4D, which indicate a great application potential in agricultural and environmental monitoring.