Therdkiat Trongwongsa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Therdkiat Trongwongsa has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jaruwan Sriwilai
Faculty of Medicine, Srinakharinwirot University, Nakhon Nayok, Thailand
2 shared publications - Napatsawan Ngamdi
Faculty of Engineering, Srinakharinwirot University, Bangkok, Thailand
2 shared publications - Sairoong Ouypornkochagorn
Faculty of Science, Naresuan University, Phitsanulok, Thailand
2 shared publications - Taweechai Ouypornkochagorn
Srinakharinwirot University
2 shared publications - Aiyada Phisaiphan
Faculty of Engineering, Srinakharinwirot University, Bangkok, Thailand
1 shared publication Fern Chanduayvit
1 shared publication
Latest Publications
- Open Access
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
High resolution digital image versus glass slide in the pathologic diagnosis of gastritis
ObjectivesGastritis is a histological diagnosis of gastric mucosal inflammation. High-resolution digital pathology is a potential alternative to glass slides for diagnosing gastritis, particularly for identifying Helicobacter pylori (H. pylori) and intestinal metaplasia (IM). This study aims to evaluate intra-observer diagnostic accuracy, grading consistency, and diagnosis time for gastritis biopsies using both glass and digital slides.MethodsA retrospective analysis of 60 gastritis cases, categorized by the presence of H. pylori and IM, was conducted. Five pathologists and one trainee with varying levels of experience participated. Diagnoses were made following the Updated Sydney System. Binary and grading concordances were assessed using Kappa statistics, and correlations between experience and concordance were analyzed. Diagnostic times were also compared across platforms.ResultsDigital slides demonstrated high concordance for H. pylori (κ = 0.73–0.86) and IM (κ = 0.86–0.93). Conversely, eosinophils (κ = 0.16–0.72) and atrophy (κ = -0.04–0.78) showed lower agreement. Diagnostic times were shorter for experienced digital pathology users but longer for inexperienced ones. Notably, no significant correlation between years of experience and diagnostic concordance was found, highlighting the need for standardized training.ConclusionsDigital slides are reliable for diagnosing H. pylori and IM, and they enhance time efficiency for experienced users. The variability observed in less emphasized features underscores the need for standardization and the potential integration of artificial intelligence (AI) to improve diagnostic consistency.
- 20 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh resolution digital image versus glass slide in the pathologic diagnosis of gastritis
ObjectivesGastritis is a histological diagnosis of gastric mucosal inflammation. High-resolution digital pathology is a potential alternative to glass slides for diagnosing gastritis, particularly for identifying Helicobacter pylori (H. pylori) and intestinal metaplasia (IM). This study aims to evaluate intra-observer diagnostic accuracy, grading consistency, and diagnosis time for gastritis biopsies using both glass and digital slides.MethodsA retrospective analysis of 60 gastritis cases, categorized by the presence of H. pylori and IM, was conducted. Five pathologists and one trainee with varying levels of experience participated. Diagnoses were made following the Updated Sydney System. Binary and grading concordances were assessed using Kappa statistics, and correlations between experience and concordance were analyzed. Diagnostic times were also compared across platforms.ResultsDigital slides demonstrated high concordance for H. pylori (κ = 0.73–0.86) and IM (κ = 0.86–0.93). Conversely, eosinophils (κ = 0.16–0.72) and atrophy (κ = -0.04–0.78) showed lower agreement. Diagnostic times were shorter for experienced digital pathology users but longer for inexperienced ones. Notably, no significant correlation between years of experience and diagnostic concordance was found, highlighting the need for standardized training.ConclusionsDigital slides are reliable for diagnosing H. pylori and IM, and they enhance time efficiency for experienced users. The variability observed in less emphasized features underscores the need for standardization and the potential integration of artificial intelligence (AI) to improve diagnostic consistency.
- Open Access
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 92087-92097
Frequency-Difference Electrical Impedance Imaging of Cervical Specimens
Screening for cervical abnormalities is crucial to reduce the risk of developing abnormal cells in the cervix. Several pathological methods have been proposed to date, however, they require exhaustive histological examination and time. In this paper, we proposed a method to localize the abnormality by using reconstruction images. The weighted frequency-difference Electrical Impedance Tomography (WfdEIT) method was implemented on three cervical specimens: one normal, one with Cervical intraepithelial neoplasia (CIN) grade 2, and one cancer specimen. A 16-electrode probe was developed to work with an EIT system operated at 2-125 kHz excitation frequencies. Experimental results have shown that the abnormalities in the specimens could be identified in most cases, represented by the positive conductivity changes. The localization of the CIN2 specimen was more accurate than that of the cancer specimen. The conductivities of the transformation zone (TZ) part and the cancer region of the specimens were significantly higher than those of the ectocervical part by 1.5-2.2 times. Interestingly, the tissue in the TZ part had a similar frequency spectrum of conductivity to the tissue with cancer and this caused difficulty to distinguish between them. The TZ region of the specimens in the reconstruction images was always positive in conductivity change in a similar manner to cancer. The abnormality imaging for identifying cancer in the TZ region is then still challenging.
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 92087-92097
Open AccessFrequency-Difference Electrical Impedance Imaging of Cervical Specimens
Screening for cervical abnormalities is crucial to reduce the risk of developing abnormal cells in the cervix. Several pathological methods have been proposed to date, however, they require exhaustive histological examination and time. In this paper, we proposed a method to localize the abnormality by using reconstruction images. The weighted frequency-difference Electrical Impedance Tomography (WfdEIT) method was implemented on three cervical specimens: one normal, one with Cervical intraepithelial neoplasia (CIN) grade 2, and one cancer specimen. A 16-electrode probe was developed to work with an EIT system operated at 2-125 kHz excitation frequencies. Experimental results have shown that the abnormalities in the specimens could be identified in most cases, represented by the positive conductivity changes. The localization of the CIN2 specimen was more accurate than that of the cancer specimen. The conductivities of the transformation zone (TZ) part and the cancer region of the specimens were significantly higher than those of the ectocervical part by 1.5-2.2 times. Interestingly, the tissue in the TZ part had a similar frequency spectrum of conductivity to the tissue with cancer and this caused difficulty to distinguish between them. The TZ region of the specimens in the reconstruction images was always positive in conductivity change in a similar manner to cancer. The abnormality imaging for identifying cancer in the TZ region is then still challenging.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Frequency-Difference Electrical Impedance Imaging of Breast Specimens
Imaging abnormality in pathological breast specimens can greatly help pathologists select sites for conducting pathological examination through a microscope. In this study, the frequency-difference Electrical Impedance Tomography (fdEIT) technique was proposed for localizing the abnormality in eight breast specimens. Three 16-electrode probes were developed for this purpose which worked with a high-SNR multifrequency EIT system. The frequencies of 10 kHz and 50 kHz were selected. The conductivity of the carcinoma masses was found 2.7-3.8 times higher than that of adipose tissues and 2-21% higher than that of fibroglandular tissues. The conductivity difference of the masses over the selected frequencies was 2.5-3.5 times higher than that of the surrounding tissues. The probes could sense to a depth of ~12 mm from the specimen surface. Five of seven specimens (71.4%) were achieved to visualize the masses. Extremely and heterogeneously dense specimens provided better mass distinction in the images than the scattered dense specimens. A mass with a diameter over 20 mm and near the measuring surface was preferable for detection. However, the mass distinction in the images also depends on the conductivity of the mass itself. Mass could be hard and soft, and the soft masses could have different conductivity. The high conductive mass tended to have a better mass distinction in the images.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Frequency-Difference Electrical Impedance Imaging of Breast Specimens
Imaging abnormality in pathological breast specimens can greatly help pathologists select sites for conducting pathological examination through a microscope. In this study, the frequency-difference Electrical Impedance Tomography (fdEIT) technique was proposed for localizing the abnormality in eight breast specimens. Three 16-electrode probes were developed for this purpose which worked with a high-SNR multifrequency EIT system. The frequencies of 10 kHz and 50 kHz were selected. The conductivity of the carcinoma masses was found 2.7-3.8 times higher than that of adipose tissues and 2-21% higher than that of fibroglandular tissues. The conductivity difference of the masses over the selected frequencies was 2.5-3.5 times higher than that of the surrounding tissues. The probes could sense to a depth of ~12 mm from the specimen surface. Five of seven specimens (71.4%) were achieved to visualize the masses. Extremely and heterogeneously dense specimens provided better mass distinction in the images than the scattered dense specimens. A mass with a diameter over 20 mm and near the measuring surface was preferable for detection. However, the mass distinction in the images also depends on the conductivity of the mass itself. Mass could be hard and soft, and the soft masses could have different conductivity. The high conductive mass tended to have a better mass distinction in the images.
- Open Access
- 20 February 2022
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 23 (1) , 43-47
Lacrimal sac lymphoma: a case report
Primary lymphoma originating from the lacrimal drainage system is a rare disease. Such lymphomas are mostly B-cell in origin and present nonspecific symptoms. The treatment of malignant lymphoma of the lacrimal drainage system is slightly different. We present the case of a 71-year-old woman with a painless mass below the medial canthus. Computed tomography (CT) scan of the orbit revealed a mass invading the right lacrimal sac. An incision biopsy was obtained, and the pathologic findings suggested a diagnosis of primary diffuse large B-cell lymphoma of the lacrimal sac. The patient was treated with chemotherapy and intrathecal methotrexate. After completing eight cycles of chemotherapy, the patient was followed up by a CT scan, which revealed nearly total resolution of an ill-defined enhancing mass. At the time of this case report writing, the patient is in complete remission at six months with no other complications.
- 20 February 2022
- Published by Korean Cleft Palate-Craniofacial Association in Archives of Craniofacial Surgery
- Vol. 23 (1) , 43-47
Open AccessLacrimal sac lymphoma: a case report
Primary lymphoma originating from the lacrimal drainage system is a rare disease. Such lymphomas are mostly B-cell in origin and present nonspecific symptoms. The treatment of malignant lymphoma of the lacrimal drainage system is slightly different. We present the case of a 71-year-old woman with a painless mass below the medial canthus. Computed tomography (CT) scan of the orbit revealed a mass invading the right lacrimal sac. An incision biopsy was obtained, and the pathologic findings suggested a diagnosis of primary diffuse large B-cell lymphoma of the lacrimal sac. The patient was treated with chemotherapy and intrathecal methotrexate. After completing eight cycles of chemotherapy, the patient was followed up by a CT scan, which revealed nearly total resolution of an ill-defined enhancing mass. At the time of this case report writing, the patient is in complete remission at six months with no other complications.