Napatsawan Ngamdi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Napatsawan Ngamdi has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Taweechai Ouypornkochagorn
Srinakharinwirot University
3 shared publications - Jaruwan Sriwilai
Faculty of Medicine, Srinakharinwirot University, Nakhon Nayok, Thailand
2 shared publications - Sairoong Ouypornkochagorn
Faculty of Science, Naresuan University, Phitsanulok, Thailand
2 shared publications - Therdkiat Trongwongsa
Faculty of Medicine, Srinakharinwirot University, Nakhon Nayok, Thailand
2 shared publications - Aiyada Phisaiphan
Faculty of Engineering, Srinakharinwirot University, Bangkok, Thailand
1 shared publication - Phanpasorn Laor-Iam
Faculty of Engineering, Srinakharinwirot University, Bangkok, Thailand
1 shared publication
Latest Publications
- Open Access
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 92087-92097
Frequency-Difference Electrical Impedance Imaging of Cervical Specimens
Screening for cervical abnormalities is crucial to reduce the risk of developing abnormal cells in the cervix. Several pathological methods have been proposed to date, however, they require exhaustive histological examination and time. In this paper, we proposed a method to localize the abnormality by using reconstruction images. The weighted frequency-difference Electrical Impedance Tomography (WfdEIT) method was implemented on three cervical specimens: one normal, one with Cervical intraepithelial neoplasia (CIN) grade 2, and one cancer specimen. A 16-electrode probe was developed to work with an EIT system operated at 2-125 kHz excitation frequencies. Experimental results have shown that the abnormalities in the specimens could be identified in most cases, represented by the positive conductivity changes. The localization of the CIN2 specimen was more accurate than that of the cancer specimen. The conductivities of the transformation zone (TZ) part and the cancer region of the specimens were significantly higher than those of the ectocervical part by 1.5-2.2 times. Interestingly, the tissue in the TZ part had a similar frequency spectrum of conductivity to the tissue with cancer and this caused difficulty to distinguish between them. The TZ region of the specimens in the reconstruction images was always positive in conductivity change in a similar manner to cancer. The abnormality imaging for identifying cancer in the TZ region is then still challenging.
- 4 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 92087-92097
Open AccessFrequency-Difference Electrical Impedance Imaging of Cervical Specimens
Screening for cervical abnormalities is crucial to reduce the risk of developing abnormal cells in the cervix. Several pathological methods have been proposed to date, however, they require exhaustive histological examination and time. In this paper, we proposed a method to localize the abnormality by using reconstruction images. The weighted frequency-difference Electrical Impedance Tomography (WfdEIT) method was implemented on three cervical specimens: one normal, one with Cervical intraepithelial neoplasia (CIN) grade 2, and one cancer specimen. A 16-electrode probe was developed to work with an EIT system operated at 2-125 kHz excitation frequencies. Experimental results have shown that the abnormalities in the specimens could be identified in most cases, represented by the positive conductivity changes. The localization of the CIN2 specimen was more accurate than that of the cancer specimen. The conductivities of the transformation zone (TZ) part and the cancer region of the specimens were significantly higher than those of the ectocervical part by 1.5-2.2 times. Interestingly, the tissue in the TZ part had a similar frequency spectrum of conductivity to the tissue with cancer and this caused difficulty to distinguish between them. The TZ region of the specimens in the reconstruction images was always positive in conductivity change in a similar manner to cancer. The abnormality imaging for identifying cancer in the TZ region is then still challenging.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Frequency-Difference Electrical Impedance Imaging of Breast Specimens
Imaging abnormality in pathological breast specimens can greatly help pathologists select sites for conducting pathological examination through a microscope. In this study, the frequency-difference Electrical Impedance Tomography (fdEIT) technique was proposed for localizing the abnormality in eight breast specimens. Three 16-electrode probes were developed for this purpose which worked with a high-SNR multifrequency EIT system. The frequencies of 10 kHz and 50 kHz were selected. The conductivity of the carcinoma masses was found 2.7-3.8 times higher than that of adipose tissues and 2-21% higher than that of fibroglandular tissues. The conductivity difference of the masses over the selected frequencies was 2.5-3.5 times higher than that of the surrounding tissues. The probes could sense to a depth of ~12 mm from the specimen surface. Five of seven specimens (71.4%) were achieved to visualize the masses. Extremely and heterogeneously dense specimens provided better mass distinction in the images than the scattered dense specimens. A mass with a diameter over 20 mm and near the measuring surface was preferable for detection. However, the mass distinction in the images also depends on the conductivity of the mass itself. Mass could be hard and soft, and the soft masses could have different conductivity. The high conductive mass tended to have a better mass distinction in the images.
- 24 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Frequency-Difference Electrical Impedance Imaging of Breast Specimens
Imaging abnormality in pathological breast specimens can greatly help pathologists select sites for conducting pathological examination through a microscope. In this study, the frequency-difference Electrical Impedance Tomography (fdEIT) technique was proposed for localizing the abnormality in eight breast specimens. Three 16-electrode probes were developed for this purpose which worked with a high-SNR multifrequency EIT system. The frequencies of 10 kHz and 50 kHz were selected. The conductivity of the carcinoma masses was found 2.7-3.8 times higher than that of adipose tissues and 2-21% higher than that of fibroglandular tissues. The conductivity difference of the masses over the selected frequencies was 2.5-3.5 times higher than that of the surrounding tissues. The probes could sense to a depth of ~12 mm from the specimen surface. Five of seven specimens (71.4%) were achieved to visualize the masses. Extremely and heterogeneously dense specimens provided better mass distinction in the images than the scattered dense specimens. A mass with a diameter over 20 mm and near the measuring surface was preferable for detection. However, the mass distinction in the images also depends on the conductivity of the mass itself. Mass could be hard and soft, and the soft masses could have different conductivity. The high conductive mass tended to have a better mass distinction in the images.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High-Precision Electrical Impedance Tomography System Using Package Excitation
In this paper, we present a high-precision multi-frequency Electrical Impedance Tomography system for wide areas of medical applications. The system has 32 channels with full parallel data acquisition. Instead of using superposition excitation for producing excitation current, we propose to use package excitation of five different frequencies between 2 kHz and 125 kHz. The excitation period is divided into five sub-periods, where only one frequency of excitation is performed at a sub-period. This excitation method can increase the readout SNR by 30 dB. The data of each frequency can be collected simultaneously. The amplitudes are programable with a maximum of 2.83 mArms. The recording speed is 20 frames per second. Eighteen-bit analog-to-digital converters are used to obtain a fine resolution with a wide measurement range. The maximum load of the current source is 2000 Ω. The SNR of the current source and the voltage measurement unit is 78.5 dB and 91.7 dB, respectively. However, the SNRs reduce to 67.9 dB and 81 dB, respectively, at the 2 kHz and 0.2 mArms of excitation. With high SNR and a wide measurement range, this system is then applicable for wide medical applications where high precision is required. The system validation was performed on a phantom tank, a human forearm, and a human chest with satisfactory results.
- 13 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-11
High-Precision Electrical Impedance Tomography System Using Package Excitation
In this paper, we present a high-precision multi-frequency Electrical Impedance Tomography system for wide areas of medical applications. The system has 32 channels with full parallel data acquisition. Instead of using superposition excitation for producing excitation current, we propose to use package excitation of five different frequencies between 2 kHz and 125 kHz. The excitation period is divided into five sub-periods, where only one frequency of excitation is performed at a sub-period. This excitation method can increase the readout SNR by 30 dB. The data of each frequency can be collected simultaneously. The amplitudes are programable with a maximum of 2.83 mArms. The recording speed is 20 frames per second. Eighteen-bit analog-to-digital converters are used to obtain a fine resolution with a wide measurement range. The maximum load of the current source is 2000 Ω. The SNR of the current source and the voltage measurement unit is 78.5 dB and 91.7 dB, respectively. However, the SNRs reduce to 67.9 dB and 81 dB, respectively, at the 2 kHz and 0.2 mArms of excitation. With high SNR and a wide measurement range, this system is then applicable for wide medical applications where high precision is required. The system validation was performed on a phantom tank, a human forearm, and a human chest with satisfactory results.