Chunchao Huang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chunchao Huang has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
Zhengqi Li
7 shared publicationsYue Lu
6 shared publicationsHuacai Liu
5 shared publicationsZhichao Chen
5 shared publicationsJingjie Wang
3 shared publicationsFan Fang
2 shared publications
Latest Publications
- 14 August 2026
- Published by Taylor & Francis in Combustion Science and Technology
- p. 1-32
Application of a Novel Strong Flame-Stabilizing Swirl Technology in a 350 MW Supercritical Boiler: Gas–Solid Flow, Combustion Characteristics, and NO x Emissions
In the past several years, China’s installed renewable energy capacity has grown steadily, and the rapid development of renewables such as wind and solar power has imposed greater requirements on t...
- 14 August 2026
- Published by Taylor & Francis in Combustion Science and Technology
- p. 1-32
Application of a Novel Strong Flame-Stabilizing Swirl Technology in a 350 MW Supercritical Boiler: Gas–Solid Flow, Combustion Characteristics, and NO x Emissions
In the past several years, China’s installed renewable energy capacity has grown steadily, and the rapid development of renewables such as wind and solar power has imposed greater requirements on t...
- 1 October 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 280
Gas–solid flow and numerical simulation of novel deep peak–shaving swirl burner burning faulty coal
- 1 October 2025
- Published by Elsevier in Applied Thermal Engineering
- Vol. 280
Gas–solid flow and numerical simulation of novel deep peak–shaving swirl burner burning faulty coal
Study on gas–particle flow and combustion stability of an improved burner for different boiler loads
- 18 March 2024
- Published by Elsevier in Thermochimica Acta
- Vol. 735
Characterisation and double parallel random pore model fitting kinetic analysis of faulty coal oxygen-enriched co-combustion
- 18 March 2024
- Published by Elsevier in Thermochimica Acta
- Vol. 735
Characterisation and double parallel random pore model fitting kinetic analysis of faulty coal oxygen-enriched co-combustion
- 8 January 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 241
Influence of secondary air blade angle and oxygen-rich combustion characteristics of an improved Babcock swirl burner
- 8 January 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 241
Influence of secondary air blade angle and oxygen-rich combustion characteristics of an improved Babcock swirl burner
- Open Access
Influence of Central Air on Flow and Combustion Characteristics and Low-Load Stabilization Performance of a Babcock Burner
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.
Open AccessInfluence of Central Air on Flow and Combustion Characteristics and Low-Load Stabilization Performance of a Babcock Burner
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.
- 28 February 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (19) , 10509-10523
Comparison of structural characteristics and combustibility analysis about hydrochar and pyrochar
The structure characteristics and combustibility of pyrochar and hydrochar were compared using scanning electron microscopy, nitrogen adsorption, Fourier transform infrared spectrum, Raman spectrum and thermogravimetry. The random pore model was applied to analyze the combustion process of chars. With the temperature increasing, analysis of physical structure revealed that the pore structure of hydrochar was more developed than that of pyrochar. Meanwhile, the hydrothermal process had an advantage over pyrolysis in terms of removing oxygen-containing functional groups and improving the coal rank, mainly attributed to the existence of subcritical water. In addition, the high determination coefficient of random pore model indicated that the model could accurately obtain the kinetic parameters. The activation energies calculated of hydrochars were higher than that of pyrochars, indicating that carbon in hydrochar had a more structural stability. The pyrochar obtained after 220 °C was less combustible than hydrochar due to its severe pore collapse during the combustion process.
- 28 February 2022
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 147 (19) , 10509-10523
Comparison of structural characteristics and combustibility analysis about hydrochar and pyrochar
The structure characteristics and combustibility of pyrochar and hydrochar were compared using scanning electron microscopy, nitrogen adsorption, Fourier transform infrared spectrum, Raman spectrum and thermogravimetry. The random pore model was applied to analyze the combustion process of chars. With the temperature increasing, analysis of physical structure revealed that the pore structure of hydrochar was more developed than that of pyrochar. Meanwhile, the hydrothermal process had an advantage over pyrolysis in terms of removing oxygen-containing functional groups and improving the coal rank, mainly attributed to the existence of subcritical water. In addition, the high determination coefficient of random pore model indicated that the model could accurately obtain the kinetic parameters. The activation energies calculated of hydrochars were higher than that of pyrochars, indicating that carbon in hydrochar had a more structural stability. The pyrochar obtained after 220 °C was less combustible than hydrochar due to its severe pore collapse during the combustion process.