Influence of Central Air on Flow and Combustion Characteristics and Low-Load Stabilization Performance of a Babcock Burner
Open Access
Abstract
On a cold single-phase test stand, the effect of central air on the exit flow field of Babcock, Germany, burner was investigated. Industrial measurements were taken for a 700 MW wall-fired pulverized-coal utility boiler with above burners. Gas temperature, gas composition and concentration in the burner area were measured at 444 MW, 522 MW and 645 MW loads, respectively. Only when the central air mass flow was zero did a center reflux zone exist in the burner outlet area. The steady combustion of faulty coal was aided by early mixing of primary and secondary air, which was made possible by the decreased central air mass flow. At all different loads, the pulverized coal in center region took a long distance to ignite. The temperature in center steadily dropped as central air mass flow decreased, while the temperature in secondary air region gradually rose. Within 1.5 m from the primary air duct outlet, the highest CO concentration was 25 ppm and the highest O2 concentration was close to 21% under all loads. The gas concentration near sidewall was more influenced by load. With all valves opening of burner center air at 30%, the boiler was able to operate safely and stably without oil at a load of 262 MW. The furnace chamber temperature in burner area reached 1056.1 °C.Keywords
This publication has 23 references indexed in Scilit:
- Aerodynamic characteristics within a cold small-scale model for a down-fired 350 MWe utility boiler applying a multiple-injection and multiple-staging technology: Effect of the staged-air declination angleExperimental Thermal and Fluid Science, 2012
- Gas/particle flow and combustion characteristics and NOx emissions of a new swirl coal burnerEnergy, 2011
- Effect of the Vane Angle for Outer Secondary Air on the Flow and Combustion Characteristics and NOxEmissions of the Low-NOxAxial-Swirl Coal BurnerNumerical Heat Transfer, Part A: Applications, 2011
- Influence of primary air ratio on flow and combustion characteristics and NOx emissions of a new swirl coal burnerEnergy, 2010
- Air Pollution and Control in Different Areas of ChinaCritical Reviews in Environmental Science and Technology, 2010
- Study on flow fields of centrally fuel rich swirl burner and its applicationsKorean Journal of Chemical Engineering, 2009
- Effect of Operation Parameters on the Slagging near Swirl Coal Burner ThroatEnergy & Fuels, 2006
- Further study of the gas temperature deviation in large-scale tangentially coal-fired boilers⋆Fuel, 2003
- EFFECTS OF CENTRAL AIR ON THE PERFORMANCE OF THE SWIRL BURNERChinese Journal of Mechanical Engineering, 2000
- on the accuracy of turbulence measurements with inclined hot wiresJournal of Fluid Mechanics, 1982