Parisa Mohammadi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Parisa Mohammadi has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Mahdi Ghorbani
Department of Chemistry, Faculty of Sciences, Ferdowsi University of Mashhad, Mashhad, Iran
3 shared publications - Majid Keshavarzi
Cellular and Molecular Research Center, Sabzevar University of Medical Sciences, Faculty of Health, Sabzevar, Iran
3 shared publications Maryam Pakseresht
Department of Chemistry, Faculty of Arts and Sciences, Near East University, Nicosia, Cyprus
3 shared publications- Morteza Mohammadi
School of Medicine, Sechenov University of Medical Sciences, Moscow, Russia
2 shared publications Abouzar Mehraban
Institute of Remote Sensing, Nanjing University of Information Science & Technology (NUIST), Nanjing, China
1 shared publication- Aliakbar Ziroohi
Department of Biology, Mashhad branch, Islamic Azad university, Mashhad, Iran
1 shared publication
Latest Publications
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 29 July 2023
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 415 (23) , 5681-5694
Optimization and synthesis of a novel sorbent composite based on magnetic chitosan-amine-functionalized bimetallic MOF for the simultaneous dispersive solid-phase microextraction of four aflatoxins in real water, herbal distillate, and food samples
Aflatoxins (AFs), an important category of pollutants, are formed in many foods and adversely affect human health. Therefore, their determination is critical to ensuring human food health. An efficient dispersive solid-phase microextraction technique was developed as a simple and straightforward sample preparation technique for determination of four aflatoxins using a high-performance liquid chromatography (HPLC) fluorescence detector. A novel efficient, green sorbent for extracting AFs was synthesized based on hydrothermal and chemical strategies. The amounts of three sorbent components were optimized using a mixture design (simplex lattice design), including 14 experiments. The optimal amount of amino-bimetallic Fe/Ni-MIL-53 nanospheres, chitosan, and magnetic Fe3O4 nanoparticles as sorbent components was 0.87, 0.67, and 0.47 g, respectively. Also, various factors affecting the process of AF determination were studied and optimized in two successive experimental designs, including the definitive screening design and the Box–Behnken design. Under optimal conditions, the linear ranges for measuring aflatoxin B1, aflatoxin B2, aflatoxin G1, and aflatoxin G2 were 0.05–82.6, 0.07–86.4, 0.08–85.7, and 0.07–89.5 ng mL−1, respectively. The relative standard deviations under inter-day and intra-day conditions for measuring AFs at three analyte concentrations were determined in triplicate analysis and were in the ranges of 3.7–4.6% and 4.9–6.1% for water sample analysis, respectively. The qualitative detection limits for determining AFs were between 0.01 and 0.05 ng mL−1. The pre-concentration factor of the method for measuring AFs ranged from 739.7 to 802.1. The proposed method was used for determining AFs in several real samples, including herbal distillate, black tea, corn, and real water samples. The relative recovery and standard deviation were 87.8–97.8% and 4.10–6.82%, respectively. Graphical abstract
- 28 February 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (8) , 1699-1718
Dispersive micro solid-phase extraction as a green procedure for extracting prostate anti-cancer drugs in real water and biological samples and optimization of sorbent composite with an optimal mixture design
A straightforward and efficient dispersive micro solid-phase extraction was developed for extracting bicalutamide and flutamide as anti-cancers in real water and biological samples. A proper sorbent composite, including a metal-organic framework (CIM-80 (Al)), magnetic Nickel oxide nanoparticles, and Chitosan, was prepared. The ratio of the sorbent components was optimised using an optimal mixture design to increase the efficiency of the synthesised sorbent in the extraction of analytes. The optimum value of CIM-80 (Al), magnetic Nickel oxide nanoparticles, and Chitosan in the sorbent composition was 0.36, 0.22, and 0.42. The sorbent was characterised using XRD, FTIR, SEM, TEM, VSM, and BET analysis. Factors affecting the microextraction process were evaluated and optimised using a fractional factorial design and a central composite design. Under optimum conditions, the procedure was linear in the concentration range of 1.2–356.4 ng mL−1 and 0.89–348.7 ng mL−1 with a coefficient of determination of 0.9951 and 0.9947 for the determination of bicalutamide and flutamide, respectively. The detection limits and inter-day RSDs % for the bicalutamide and flutamide determination were lower than 0.35 ng mL−1 and 6.21%, respectively. Analysis of real water, drug-free urine, drug-free plasma, and post-drug urine samples indicated that the method has a high ability to analyse water and biological samples for the bicalutamide and flutamide determination. The method’s effects on the environment for the bicalutamide and flutamide determination were evaluated using the Green Analytical Procedure Index and Analytical Eco-Scale.
- 28 February 2022
- Published by Taylor & Francis in International Journal of Environmental Analytical Chemistry
- Vol. 104 (8) , 1699-1718
Dispersive micro solid-phase extraction as a green procedure for extracting prostate anti-cancer drugs in real water and biological samples and optimization of sorbent composite with an optimal mixture design
A straightforward and efficient dispersive micro solid-phase extraction was developed for extracting bicalutamide and flutamide as anti-cancers in real water and biological samples. A proper sorbent composite, including a metal-organic framework (CIM-80 (Al)), magnetic Nickel oxide nanoparticles, and Chitosan, was prepared. The ratio of the sorbent components was optimised using an optimal mixture design to increase the efficiency of the synthesised sorbent in the extraction of analytes. The optimum value of CIM-80 (Al), magnetic Nickel oxide nanoparticles, and Chitosan in the sorbent composition was 0.36, 0.22, and 0.42. The sorbent was characterised using XRD, FTIR, SEM, TEM, VSM, and BET analysis. Factors affecting the microextraction process were evaluated and optimised using a fractional factorial design and a central composite design. Under optimum conditions, the procedure was linear in the concentration range of 1.2–356.4 ng mL−1 and 0.89–348.7 ng mL−1 with a coefficient of determination of 0.9951 and 0.9947 for the determination of bicalutamide and flutamide, respectively. The detection limits and inter-day RSDs % for the bicalutamide and flutamide determination were lower than 0.35 ng mL−1 and 6.21%, respectively. Analysis of real water, drug-free urine, drug-free plasma, and post-drug urine samples indicated that the method has a high ability to analyse water and biological samples for the bicalutamide and flutamide determination. The method’s effects on the environment for the bicalutamide and flutamide determination were evaluated using the Green Analytical Procedure Index and Analytical Eco-Scale.
- 26 December 2021
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 53 (6) , 1285-1312
Developments of Microextraction (Extraction) Procedures for Sample Preparation of Antidepressants in Biological and Water Samples, a Review
Antidepressants are an important class of drugs to treat various types of depression. The determination of antidepressants is crucial in biological samples to control adverse effects in humans and study pharmacokinetics and bioavailability. Direct measurement of antidepressants in biological and water samples is a considerable challenge for analysts due to their low concentration, the high matrix effects of real samples, and the presence of metabolites of these drugs in biological samples. The challenge leads to using sample preparation processes as a critical step in determining antidepressants. Extraction and microextraction procedures have been widely utilized as sample preparation procedures for these drugs. The purposes of extraction or microextraction methods for antidepressant medications are to preconcentrate the analyte, reduce the matrix effects, increase the selectivity of the procedures, and convert the sample to a suitable format for introducing it into detection systems. In the review, the various extraction and microextraction methods of these drugs in biological, real water, and wastewater samples were investigated. The theory of each technique was briefly addressed to understand the features and factors affecting each method. The extraction and microextraction methods were classified based on their application for antidepressants, and the advantages and disadvantages of each technique were reviewed. The new developments to overcome the limitations of each procedure were discussed. The investigation indicated the number of applications of liquid-phase microextraction for extracting antidepressants has been almost equal to that of solid-phase microextraction.
- 26 December 2021
- Published by Taylor & Francis in Critical Reviews in Analytical Chemistry
- Vol. 53 (6) , 1285-1312
Developments of Microextraction (Extraction) Procedures for Sample Preparation of Antidepressants in Biological and Water Samples, a Review
Antidepressants are an important class of drugs to treat various types of depression. The determination of antidepressants is crucial in biological samples to control adverse effects in humans and study pharmacokinetics and bioavailability. Direct measurement of antidepressants in biological and water samples is a considerable challenge for analysts due to their low concentration, the high matrix effects of real samples, and the presence of metabolites of these drugs in biological samples. The challenge leads to using sample preparation processes as a critical step in determining antidepressants. Extraction and microextraction procedures have been widely utilized as sample preparation procedures for these drugs. The purposes of extraction or microextraction methods for antidepressant medications are to preconcentrate the analyte, reduce the matrix effects, increase the selectivity of the procedures, and convert the sample to a suitable format for introducing it into detection systems. In the review, the various extraction and microextraction methods of these drugs in biological, real water, and wastewater samples were investigated. The theory of each technique was briefly addressed to understand the features and factors affecting each method. The extraction and microextraction methods were classified based on their application for antidepressants, and the advantages and disadvantages of each technique were reviewed. The new developments to overcome the limitations of each procedure were discussed. The investigation indicated the number of applications of liquid-phase microextraction for extracting antidepressants has been almost equal to that of solid-phase microextraction.