Miaomiao Ji
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Miaomiao Ji has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Guanghui Wang
College of Engineering and Applied Sciences, Nanjing University, Nanjing, China
3 shared publications - Binzhen Zhang
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications - Junping Duan
State Key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan 030051, China
2 shared publications Rouyu Su
College of Engineering and Applied Sciences, Nanjing University, Jiangsu, 210093, China; Key Laboratory of Intelligent Optical Sensing and Integration of the Ministry of Education, Nanjing University, Jiangsu, 210009, China
2 shared publications- Ya Zhang
College of Engineering and Applied Sciences, Nanjing University, Jiangsu 210093, China
2 shared publications - Yukai Liu
College of Engineering and Applied Sciences, Nanjing University, Nanjing, 210093, PR China
2 shared publications
Latest Publications
- Open Access
- 8 July 2025
- Published by Wiley in Advanced Science
- Vol. 12 (32) , e07724
Deep Learning‐Assisted Rapid Bacterial Classification Based on Raman Spectroscopy of Bacteria Lysed by Acoustically Driven Fiber‐Tip Vibration
Rapid and accurate identification of bacterial pathogens is critical for effective clinical decision‐making and combating antibiotic resistance. Surface‐enhanced Raman spectroscopy (SERS) combined with machine learning (ML) offers a powerful method for rapid, label‐free bacterial identification. Conventional methods rely on surface molecular structures for identification, yet the richer and unique spectral information from intracellular biomolecules is often masked by the bacterial envelope, limiting classification accuracy. Here, a novel bacterial classification method is demonstrated by introducing acoustofluidic lysis based on the vibrating fiber‐tip, combined with Raman spectroscopy and deep learning. The fiber‐tip oscillates in a torsional mode, generating a controlled single‐vortex within a capillary to concentrate bacteria in high‐shear regions, enhancing lysis efficiency. This process effectively exposes intracellular components such as nucleic acids, proteins, and lipids, significantly enhancing the expression of features in bacterial Raman spectra, improving both spectral resolution and information richness. A residual neural network (ResNet) model is further employed for automated classification, achieving 98.9% accuracy across seven bacterial samples, surpassing traditional classifiers like random forests. The clinical validation experiments highlight the method's potential for real‐world applications, enabling direct, on‐site detection of clinical samples and facilitating rapid diagnostics, thus offering a promising advancement in pathogen identification.
- 8 July 2025
- Published by Wiley in Advanced Science
- Vol. 12 (32) , e07724
Open AccessDeep Learning‐Assisted Rapid Bacterial Classification Based on Raman Spectroscopy of Bacteria Lysed by Acoustically Driven Fiber‐Tip Vibration
Rapid and accurate identification of bacterial pathogens is critical for effective clinical decision‐making and combating antibiotic resistance. Surface‐enhanced Raman spectroscopy (SERS) combined with machine learning (ML) offers a powerful method for rapid, label‐free bacterial identification. Conventional methods rely on surface molecular structures for identification, yet the richer and unique spectral information from intracellular biomolecules is often masked by the bacterial envelope, limiting classification accuracy. Here, a novel bacterial classification method is demonstrated by introducing acoustofluidic lysis based on the vibrating fiber‐tip, combined with Raman spectroscopy and deep learning. The fiber‐tip oscillates in a torsional mode, generating a controlled single‐vortex within a capillary to concentrate bacteria in high‐shear regions, enhancing lysis efficiency. This process effectively exposes intracellular components such as nucleic acids, proteins, and lipids, significantly enhancing the expression of features in bacterial Raman spectra, improving both spectral resolution and information richness. A residual neural network (ResNet) model is further employed for automated classification, achieving 98.9% accuracy across seven bacterial samples, surpassing traditional classifiers like random forests. The clinical validation experiments highlight the method's potential for real‐world applications, enabling direct, on‐site detection of clinical samples and facilitating rapid diagnostics, thus offering a promising advancement in pathogen identification.
- 28 January 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 274, 117212
An ultrasensitive one-pot Cas13a-based microfluidic assay for rapid multiplexed detection of microRNAs
- 28 January 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 274, 117212
An ultrasensitive one-pot Cas13a-based microfluidic assay for rapid multiplexed detection of microRNAs
- 18 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (2) , 263-274
3D-printed acoustic metasurface with encapsulated micro-air-bubbles for frequency-selective manipulation
A low-frequency acoustic metasurface with PDMS-stabilized microbubbles achieves stable vibration modes, precise control over micro-object aggregation, rotation, separation, and selective trajectory manipulation through frequency-tuned excitation.
- 18 December 2024
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 25 (2) , 263-274
3D-printed acoustic metasurface with encapsulated micro-air-bubbles for frequency-selective manipulation
A low-frequency acoustic metasurface with PDMS-stabilized microbubbles achieves stable vibration modes, precise control over micro-object aggregation, rotation, separation, and selective trajectory manipulation through frequency-tuned excitation.
- 28 February 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (3) , 035307
High throughput particle sorting based on traveling surface acoustic wave (TSAW) is realized by coupling spiral microchannel and a novel arc electrode
Acoustofluidic technology is an ideal tool for biomedical applications. However, the sorting performance and flux of acoustofluidic chips cannot be achieved simultaneously. In this paper, we propose a method for coupling a novel arc gold interdigital transducer (IDT) with a spiral microchannel. A spiral microchannel is used to focus the target particle (20 μm) inertially to improve the sorting efficiency of the chip. The channel uses a Y-shaped inlet to bind small particles (5 μm) in a fixed stream beam to improve the sorting efficiency of the chip. The fit of arc electrode and spiral flow channel enlarges the acoustic control area, so that the target particles can still be separated effectively at high flow velocity. The results show that when the signal source frequency is 33.7 MHz and the voltage is 5 V, the designed chip can effectively separate the target particles at the flow rate of 25–65 μl min−1, and the sorting purity is 100%. The sorting efficiency decreased with the increase of flow rate, 25 μl min−1: 100 %, 35 μl min−1: 100 %, 45 μl min−1: 94 .8% (within 1.2% error), 55 μl min−1: 92 % (within 1% error), 65 μl min−1: 83 .4% (within 2.4% error). This chip provides an idea for achieving high throughput, high purity and high efficiency cell sorting.
- 28 February 2023
- Published by IOP Publishing in Physica Scripta
- Vol. 98 (3) , 035307
High throughput particle sorting based on traveling surface acoustic wave (TSAW) is realized by coupling spiral microchannel and a novel arc electrode
Acoustofluidic technology is an ideal tool for biomedical applications. However, the sorting performance and flux of acoustofluidic chips cannot be achieved simultaneously. In this paper, we propose a method for coupling a novel arc gold interdigital transducer (IDT) with a spiral microchannel. A spiral microchannel is used to focus the target particle (20 μm) inertially to improve the sorting efficiency of the chip. The channel uses a Y-shaped inlet to bind small particles (5 μm) in a fixed stream beam to improve the sorting efficiency of the chip. The fit of arc electrode and spiral flow channel enlarges the acoustic control area, so that the target particles can still be separated effectively at high flow velocity. The results show that when the signal source frequency is 33.7 MHz and the voltage is 5 V, the designed chip can effectively separate the target particles at the flow rate of 25–65 μl min−1, and the sorting purity is 100%. The sorting efficiency decreased with the increase of flow rate, 25 μl min−1: 100 %, 35 μl min−1: 100 %, 45 μl min−1: 94 .8% (within 1.2% error), 55 μl min−1: 92 % (within 1% error), 65 μl min−1: 83 .4% (within 2.4% error). This chip provides an idea for achieving high throughput, high purity and high efficiency cell sorting.
- 7 March 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (4) , 045004
Ultra-high precision passive particle sorting chip coupling inertial microfluidics and single row micropillar arrays
In this work, we propose a chip for high-throughput and high-precision particle sorting through coupled inertial microfluidics and a single-row micropillar array. The effect of a single-row micropillar array arrangement on the separation effect was studied in order to optimize the structure. The micropillar array was set to be 1/4 away from the outlet. The offset single row micropillar array can achieve higher precision sorting effect after optimization. Compared with cascaded deterministic lateral displacement arrays to the outer spiral, this structure not only reduces the chip size, but also has a lower blocking probability. In addition, the problem of flow resistance mismatch is avoided. Our chip sorting efficiency is higher in comparison with pure inertial microfluidic chip. Our chip successfully completely separated a small amount of 20 μ m particles from the mixture of 5 μ m particles and 20 μ m particles through experiments, and the separation efficiency was close to 100%. Our chip structure has simple processing technology and low cost, which is suitable for the high-precision separation of two different particle sizes. High flux can be achieved by using passive separation technology. The chip can withstand a maximum flow rate of 9.4 m s −1 . In general, it provides a new idea for ultra-high precision particle separation and microfluidic chip manufacturing at high flow rates.
- 7 March 2022
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 32 (4) , 045004
Ultra-high precision passive particle sorting chip coupling inertial microfluidics and single row micropillar arrays
In this work, we propose a chip for high-throughput and high-precision particle sorting through coupled inertial microfluidics and a single-row micropillar array. The effect of a single-row micropillar array arrangement on the separation effect was studied in order to optimize the structure. The micropillar array was set to be 1/4 away from the outlet. The offset single row micropillar array can achieve higher precision sorting effect after optimization. Compared with cascaded deterministic lateral displacement arrays to the outer spiral, this structure not only reduces the chip size, but also has a lower blocking probability. In addition, the problem of flow resistance mismatch is avoided. Our chip sorting efficiency is higher in comparison with pure inertial microfluidic chip. Our chip successfully completely separated a small amount of 20 μ m particles from the mixture of 5 μ m particles and 20 μ m particles through experiments, and the separation efficiency was close to 100%. Our chip structure has simple processing technology and low cost, which is suitable for the high-precision separation of two different particle sizes. High flux can be achieved by using passive separation technology. The chip can withstand a maximum flow rate of 9.4 m s −1 . In general, it provides a new idea for ultra-high precision particle separation and microfluidic chip manufacturing at high flow rates.
- Open Access
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035148
Continuous particle separation of microfluidic chip with integrated inertial separation and dielectrophoresis separation
Particle separation is essential in many microfluidic systems such as biomedical analysis and chemical reactions. This study aims to report a microfluidic separation device combining dielectrophoresis force and inertial force to separate particles continuously. Most particles were separated by inertial force via passing through the contraction and expansion channel and then deviated into different outlets via interdigital electrodes. Numerical simulations using the software COMSOL Multiphysics 5.4 were performed to investigate the effects of flow rate and electric field distribution on particles. The separation efficiency was assessed by separating 4 µm polystyrene spheres (PS) from 20 µm PS microspheres at various flow rates. The experimental results showed that the separation efficiency was more than 95%. This microfluidic chip is expected to be applied to cell sorting and biomedicine.
- 1 March 2022
- Published by AIP Publishing in AIP Advances
- Vol. 12 (3) , 035148
Open AccessContinuous particle separation of microfluidic chip with integrated inertial separation and dielectrophoresis separation
Particle separation is essential in many microfluidic systems such as biomedical analysis and chemical reactions. This study aims to report a microfluidic separation device combining dielectrophoresis force and inertial force to separate particles continuously. Most particles were separated by inertial force via passing through the contraction and expansion channel and then deviated into different outlets via interdigital electrodes. Numerical simulations using the software COMSOL Multiphysics 5.4 were performed to investigate the effects of flow rate and electric field distribution on particles. The separation efficiency was assessed by separating 4 µm polystyrene spheres (PS) from 20 µm PS microspheres at various flow rates. The experimental results showed that the separation efficiency was more than 95%. This microfluidic chip is expected to be applied to cell sorting and biomedicine.