JXJingtian Xi

Jingtian Xi

*This is an algorithmically generated author record based on publicly available information.

Jingtian Xi has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Evaluation of Exposure Assessment Methods and Procedures for Induction Hobs

    by Jingtian Xi, Sven Kühn, Cosimo Fortunato, Erdem Ofli, Niels Kuster

    Induction hobs generate strong alternating magnetic fields to heat pots by inducing eddy currents. These fields are the strongest close to the bottom of the cookware, but stray fields at large distances can still be substantial. In general, these are higher than the reference levels defined by international electromagnetic exposure safety guidelines (ICNIRP 1998; ICNIRP 2010; IEEE 2019). That the reference levels are exceeded does not imply that the basic restrictions are also violated. In this study, we assess the exposures caused by the latest generation of induction hobs by applying the advanced instrumentation and different methods that include the procedures developed by the International Electrotechnical Commission (IEC) for household appliances (IEC 62233) (IEC International Electrotechnical Commission 2005), the 4‐tier approach developed for inductive wireless power transfer systems (IEC 63184) (IEC International Electrotechnical Commission 2021), and their derivatives. First, methods for determining the maximum exposure configuration were assessed. Then, the 3D distribution of the incident magnetic field was sampled with a scanning system and analyzed, and the contact currents assessed. Lastly, numerical dosimetric evaluations were performed in anatomical models to determine the maximum fields induced by the measured incident fields directly or by a representative coil model converted from the measured fields. The study's findings reveal significant variations in exposure across different induction hobs, with differences of up to a factor of 20 ( 26 dB) as a function of power, coil size, and proximity to the coil. This suggests that low‐exposure hobs can be designed without compromising cooking performance. Furthermore, the study strengthens the conclusions of previous studies that IEC 62233 (IEC International Electrotechnical Commission 2005) may underestimate the exposure for persons standing next to the hob by up to a factor of 30—based on testing according to the exposure limits from (ICNIRP 1998; IEEE 2019)—and thus does not ensure safety. A dosimetric analysis, the most accurate method, would be relatively costly. Alternative approaches derived from (IEC International Electrotechnical Commission, 2021) that are affordable and not overly conservative are discussed. Bioelectromagnetics. 00:00–00, 2025. © 2025 Bioelectromagnetics Society.


  • Open Access

    Dosimetric Electromagnetic Safety of People With Implants: A Neglected Population?

    by Lena Kranold, Jingtian Xi, Tolga Goren, Niels Kuster

    Electromagnetic (EM) safety guidelines are designed to protect the general public and workers from the risks posed by exposure to EM sources of all types, with the exception of medical EM sources. However, it has never been systematically evaluated whether individuals with conductive implants are also protected by these guidelines or whether the local field enhancement due to presence of the implant may pose an unacceptable risk under certain realistic exposure conditions. To address this important knowledge and regulatory gap, we first evaluated the upper bound of the local enhancement of bare and insulated generic implants of 0.5 λ (approximately equal to resonant) and 0.1 λ lengths, but restricted the maximum length to 2 m, as a function of tissue properties and frequency (10 kHz to 1 GHz). Results for uniform electric field excitation showed local enhancement of psSAR 10mg and of locally averaged E‐field, respectively, compared to the background in the presence of a generic implant of 10 dB (1 GHz) to over 100 dB at frequencies under 100 MHz. In the next step, we tested the hypothesis that fields induced inside the human body by realistic near‐field sources are not sufficiently uniform to generate results in enhancement that could pose unacceptable risk. Common implant trajectories were inserted into the Virtual Population human anatomical model Ella V3.0, and the model was exposed to the following conditions (i) a standard source representing a wireless power transfer source operating at 85 kHz and (ii) a dipole source that operates at 450 MHz within the current exposure limits. Results show that the safety limit is exceeded at the tip of the implant by a factor of >  10 ( > 20 dB) or >  115 V/m at 85 kHz, whereas the locally induced specific absorption rate averaged over 10 mg at 450 MHz was 7.9 W/kg, resulting in a temperature increase after 6 min of <  0.4 K. Hence, as the hypothesis was falsified at frequencies <  450 MHz, patients with implants are inadequately protected by current safety and product guidelines. In the discussions, proposals for how to close this regulatory gap are provided. Bioelectromagnetics. 00:00–00, 2025. © 2025 Bioelectromagnetics Society.


  • Open Access

    Calculated Epithelial/Absorbed Power Density for Exposure From Antennas at 10–90 GHz: Intercomparison Study Using a Planar Skin Model

    by Kun Li, Sachiko Kodera, Dragan Poljak, Yinliang Diao, Kensuke Sasaki, Anna Šušnjara, Alexander Prokop, Kenji Taguchi, Jingtian Xi, Shuai Zhang, et al.

    International organizations have collaborated to revise standards and guidelines for human protection from exposure to electromagnetic fields. In the frequency range of 6–300 GHz, the permissible spatially averaged epithelial/absorbed power density, which is primarily derived from thermal modeling, is considered the basic restriction. However, for the averaging methods of the epithelial/absorbed power density inside human tissues, only a few groups have presented calculated results obtained using different exposure conditions and numerical methods. Because experimental validation is extremely difficult in this frequency range, this paper presents the first intercomparison study of the calculated epithelial/absorbed power density inside a human body model exposed to different frequency sources ranging from 10–90 GHz. This intercomparison aims to clarify the difference in the calculated results caused by different numerical electromagnetic methods in dosimetry analysis from 11 research groups using planar skin models. To reduce the comparison variances caused by various key parameters, computational conditions (e.g., the antenna type, dimensions, and dielectric properties of the skin models) were unified. The results indicated that the maximum relative standard deviation (RSD) of the peak spatially averaged epithelial/absorbed power densities for one- and three-layer skin models were less than 17.49% and 17.39%, respectively, when using a dipole antenna as the exposure source. For the dipole array antenna, the corresponding maximum RSD increased to 32.49% and 42.55%, respectively. Under the considered exposure scenarios, the RSD in the spatially averaged epithelial/absorbed power densities decreased from 42.55% to 16.7% when the frequency was increased from 10–90 GHz. Furthermore, the deviation from the two equations recommended by the exposure guidelines for deriving the spatially averaged epithelial/absorptive power density was mostly within 1 dB. The fair agreement in the intercomparison results demonstrates that the variances of the spatially averaged epithelial/absorbed power densities calculated using planar skin models are marginal.


  • Coverage factors for efficient demonstration of compliance of low-frequency magnetic near-field exposures with basic restrictions

    by Jingtian Xi, Andreas Christ, Niels Kuster

    Objective . Regulators require that wireless power transfer (WPT) systems and other strong magnetic field sources are compliant with the basic restrictions (BR) defined as the limits of the fields induced in the human body, i.e. the induced electric field/current density/specific absorption rate limits. This can be achieved by demonstrating compliance with the reference levels (RL) defined in air without the human body, i.e. the incident electric/magnetic field limits. Local sources, such as WPT transmitters, generate non-uniform fields that can locally exceed the RL while the induced fields are still well below the BR. In these cases, robust compliance with BR can be demonstrated, generally requiring a large number of simulations. In this study, we proposed an efficient evaluation using a homogeneous phantom and applying a coverage factor to account for the local field enhancements caused by the dielectric contrasts of the highly inhomogeneous human tissues. Approach . The generally applicable coverage factors were derived from a statistical analysis of the field enhancements observed on four magnetic near-field sources placed at different separation distances (2–80 mm) and locations on the back of 12 anatomical models. The field enhancements were characterized by the ratios between the peak induced fields in the anatomical models and those in the homogeneous half-space phantom ( ϵ r = 55, σ = 0.75 S m −1 , ρ = 1,000 kg m −3 ) at the same distance. Main results . The resulting 99th percentile coverage factors range from 1 and 9 depending on the dosimetric quantity. Significance . The use of these coverage factors reduces the compliance testing effort from hundreds of simulations to only one, and makes experimental testing feasible without the support of simulations. The study also demonstrates that running only a few use-case simulations with anatomical models may underestimate the exposure by more than 10 dB.


  • Open Access

    Intercomparison of Calculated Incident Power Density and Temperature Rise for Exposure From Different Antennas at 10–90 GHz

    by Kun Li, Yinliang Diao, Kensuke Sasaki, Alexander Prokop, Dragan Poljak, Vicko Doric, Jingtian Xi, Sachiko Kodera, Akimasa Hirata, Walid El Hajj

    Recently, international exposure guidelines/standards for human protection from electromagnetic fields were revised. For frequencies between 6-300 GHz, the permissible incident power density is defined as the reference level, which is derived from a new metric “absorbed/epithelial power density” based on thermal modeling. However, only a few groups computed the power density and the resultant temperature rise at frequencies greater than 6 GHz, where their exposure conditions were different. This study presents the first intercomparison study of the incident power density and the resultant temperature rise in a human body exposed to different frequency sources ranging from 10 to 90 GHz. This intercomparison aims to clarify the main causes of numerical calculation errors in dosimetry analyses through objective comparison of computation results from six organizations using their numerical methods with various body and antenna models. The intercomparison results indicate that the maximum relative standard deviation (RSD) of peak spatially averaged incident power densities for dipole and dipole array antennas is less than 22.1% and 6.3%, respectively. The maximum RSD of the heating factor, which is defined as the ratio of the peak temperature elevation at the skin surface to the peak spatially averaged incident power density in free space, for dipole and dipole array antennas is less than 43.2% and 41.2%, respectively. The deviations in the heating factors caused by different body models and dielectric/thermal parameters are within 33.1% and 19.6% at 10 and 30 GHz, respectively, when the antenna-to-skin model distance is greater than 5 mm. Under this condition (>5 mm), the deviation in the heating factors caused by different antenna models at 30 GHz does not exceed 26.3%. The fair agreement among the intercomparison results demonstrates that numerical calculation errors of dosimetry analyses caused by the definition of spatially averaged incident power density are marginal.


  • Open Access

    Forward Transformation from Reactive Near-Field to Near and Far-Field at Millimeter-Wave Frequencies

    by Serge Pfeifer, Arya Fallahi, Jingtian Xi, Esra Neufeld, Niels Kuster

    With the advent of 5G mobile communications at millimeter-wave frequencies, the assessment of the maximum averaged power density on numerous surfaces close to the transmitter will become a requirement. This makes phasor knowledge about the electric and magnetic fields an inevitable requirement. To avoid the burdensome measurement of these field quantities in the entire volume of interest, phase reconstruction algorithms from measurements over a plane in the far-field region are being extensively developed. In this paper, we extended the previously developed method of phase reconstruction to evaluate the near and far-field of sources with bounded uncertainty, which is robust with respect to noisy data and optimized for a minimal number of measurement points at a distance as close as λ /5 from the source. The proposed procedure takes advantage of field integral equations and electric field measurements with the EUmmWVx probe to evaluate the field phasors close to the radiation source and subsequently obtain the field values in the whole region of interest with minimal computation and measurement costs. The main constraints are the maximal noise level regarding the peak electric field and measurement plane size with respect to the percentage of transmitted power content. The measurement of a third plane overcomes some of the noise issues. The method was evaluated by simulations of a wide range of antennas at different noise levels and at different distances and by measurements of four different antennas. A successful reconstruction in the near and far-field was achieved both qualitatively and quantitatively for distances between 2.5–150 mm from the antenna and noise levels of −24 dB from the peak. The deviation of reconstruction from the simulation reference for the peak spatial-average power density with an averaging area of 1 cm 2 was, in all cases, well within the uncertainty budget of 0.6 dB, if the reconstruction planes captured >95% of the total radiated power. The proposed new method is very promising for compliance assessment and can reduce test time considerably.


  • A compact HF/UHF dual band RFID tag antenna

    by Zi Long Ma, Li Jun Jiang, Jingtian Xi, Terry Tao Ye

    This paper presents a novel dual band RFID (radio frequency identification) tag antenna. Two challenges are faced: the compact dimension and the impaired bandwidth due to the couplings between two band structures. A spiral coil is designed to handle the HF (13.56MHz) near field coupling, and a diagonal symmetric design consisting of two meander lines are placed inside the coil for UHF band (915MHz). This structure supports multiple resonance modes around 915MHz to broaden the working bandwidth under the large inductive circumstance from the HF coil. The proposed antenna is easy to adjust by both coarse tuning and fine tuning. Its overall dimension is of a credit card size on a single layer thin substrate.


  • Open Access

    Research on Stable, High-Efficiency Amorphous Silicon Multijunction Modules, Annual Subcontract Report, 1 November 1992 - 31 May 1993

    by M. Ghosh, F. Kampas, J. Xi

    This report describes progress made in the first half of Phase II of a three-phase program to develop high-efficiency, same-band-gap, amorphous-silicon, tandem-junction modules. Results for both 1-cm- {sup 2} devices and 0.3-m (0.09-m{sup 2}) modules are given. considerable effort was devoted to finding a device structure and layer conditions that reconcile the conflicting requirements of a good ``tunnel junction`` contact between the two stacks and a high-efficiency device. High-band-gap p{sub 2}layers, which enable good voltage and current from the second stack, were found to result in poor tunnel junctions. The best results were obtained by using a thin (1-nm-thick) p{sup +} layer (no carbon) between the n{sub 1} and p{sub 2} layers of the device.