Weijiang Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Weijiang Xu has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Yan Li
Harbin Institute of Technology
3 shared publications - Jinjian Li
School of Optoelectronic Engineering, Guilin University of Electronic Technology, Guilin, China
2 shared publications - Shiliang Qu
Guangxi Key Laboratory of Optoelectronic Information Processing, School of Optoelectronic Engineering, Guilin University of Electronic Technology, Guilin, China
2 shared publications - Yi Liu
School of Science, Harbin Institute of Technology, Weihai, China
2 shared publications - Yi Liu
Department of Optoelectronics Science, Harbin Institute of Technology, Weihai, China
2 shared publications - An Xia
School of Optoelectronic Engineering, Guilin University of Electronic Technology, Guilin, China
1 shared publication
Latest Publications
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Highly Sensitive Microdisplacement Sensor Based on Sidewall Resonance Effect of Optical Fiber Liquid Cladding
Optical fiber displacement sensors are extensively used in pre-warning of landslide and earthquake. Here, we propose a highly sensitive micro-displacement sensor based on side-wall (SR) resonance effect of optical fiber liquid cladding. The sensor structure has two single-mode fibers (SMF) fused at both ends of a no-core fiber (NCF), placed in a glass capillary filled with cedar oil. The effective refractive index (RI) of the cedar oil can be matched with the RI of optical fiber, which is conducive to the SR effect. The micro-displacement of the monitored object will cause the bending of the sensing structure, resulting in a change in the thickness of the liquid cladding and the shifting of the SR dips in output spectrum. Besides, we introduce a piece of tapered no-core fiber (TNCF) into the original structure. Experimental results demonstrate that the displacement sensitivity of improved structure is increased from 5.02 nm/μm to 9.02 nm/μm, compared to the sensor with NCF, while the compensated temperature sensitivity is increased from –3.69 nm/°C to –13.76 nm/°C. Due to the excellent performance of the micro-displacement sensing structure based on SR effect of optical fiber liquid cladding, it offers broad prospects for applications such as monitoring earthquake waves and building frame.
- 18 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-9
Highly Sensitive Microdisplacement Sensor Based on Sidewall Resonance Effect of Optical Fiber Liquid Cladding
Optical fiber displacement sensors are extensively used in pre-warning of landslide and earthquake. Here, we propose a highly sensitive micro-displacement sensor based on side-wall (SR) resonance effect of optical fiber liquid cladding. The sensor structure has two single-mode fibers (SMF) fused at both ends of a no-core fiber (NCF), placed in a glass capillary filled with cedar oil. The effective refractive index (RI) of the cedar oil can be matched with the RI of optical fiber, which is conducive to the SR effect. The micro-displacement of the monitored object will cause the bending of the sensing structure, resulting in a change in the thickness of the liquid cladding and the shifting of the SR dips in output spectrum. Besides, we introduce a piece of tapered no-core fiber (TNCF) into the original structure. Experimental results demonstrate that the displacement sensitivity of improved structure is increased from 5.02 nm/μm to 9.02 nm/μm, compared to the sensor with NCF, while the compensated temperature sensitivity is increased from –3.69 nm/°C to –13.76 nm/°C. Due to the excellent performance of the micro-displacement sensing structure based on SR effect of optical fiber liquid cladding, it offers broad prospects for applications such as monitoring earthquake waves and building frame.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (1) , 369-375
Heat Typed Fiber Liquid Flow Sensor With Wide Sensing Range and High Sensitivity
In this paper, a heat typed fiber sensor for microfluidic velocity measurement with large sensing range and high sensitivity is demonstrated. The single-mode fiber (SMF) end face and polymer cap form a Fabry Perot (FP) structure. The Au film layer on the surface of the polymer cap is heated by an infrared laser, and the heated Au film layer undergoes heat transfer to the polymer cap structure, causing it to expand upon heating. Due to the heat carried away by the polymer cap structure at the action of microfluidic rates, the cavity length of the polymer cap structure changes. Therefore, the flow rate can be measured by monitoring the wavelength drift of the interference spectrum. The experimental results indicate that the laser can induced heat and transfer to the probe because the Au film has excellent thermal conductivity. Furthermore, the probe has a good response to the flow rate. The probe has advantages of simple preparation, small size, and strong structure, which can be used for micro flow rate sensing with wide sensing range and high sensitivity.
- 30 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 43 (1) , 369-375
Heat Typed Fiber Liquid Flow Sensor With Wide Sensing Range and High Sensitivity
In this paper, a heat typed fiber sensor for microfluidic velocity measurement with large sensing range and high sensitivity is demonstrated. The single-mode fiber (SMF) end face and polymer cap form a Fabry Perot (FP) structure. The Au film layer on the surface of the polymer cap is heated by an infrared laser, and the heated Au film layer undergoes heat transfer to the polymer cap structure, causing it to expand upon heating. Due to the heat carried away by the polymer cap structure at the action of microfluidic rates, the cavity length of the polymer cap structure changes. Therefore, the flow rate can be measured by monitoring the wavelength drift of the interference spectrum. The experimental results indicate that the laser can induced heat and transfer to the probe because the Au film has excellent thermal conductivity. Furthermore, the probe has a good response to the flow rate. The probe has advantages of simple preparation, small size, and strong structure, which can be used for micro flow rate sensing with wide sensing range and high sensitivity.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34417-34423
Ultracompact Temperature-Compensated All-Fiber Ultraviolet Sensor Based on CdZnSe/ZnSe/ZnS Quantum Dots Sealed in Liquid Cavity
An ultra-compact temperature-compensated all-fiber ultraviolet sensor based on CdZnSe/ZnSe/ZnS quantum dots sealed in liquid-cavity is proposed. The ultraviolet-sensitive region is integrated inside the fiber to avoid interference from external media, and high fluorescence conversion efficiency and ultra-compact structure are achieved due to the high fluorescence quantum efficiency and excellent luminescence stability of CdZnSe/ZnSe/ZnS quantum dots solution. The temperature crosstalk problem of semiconductor materials applied to sensors is solved in this single structure by monitoring of peak wavelength and intensity of fluorescence spectra simultaneously to achieve the temperature compensation function of the sensor. The results show linear dependence of UV sensitivity on temperature which is able to be demodulated through peak wavelength individually. In addition, the quantum dots sealed in liquid-cavity protected by hollow core fiber can resist corrosion, high pressure, and electromagnetic interference, providing a new idea for UV detection in harsh environments.
- 22 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (21) , 34417-34423
Ultracompact Temperature-Compensated All-Fiber Ultraviolet Sensor Based on CdZnSe/ZnSe/ZnS Quantum Dots Sealed in Liquid Cavity
An ultra-compact temperature-compensated all-fiber ultraviolet sensor based on CdZnSe/ZnSe/ZnS quantum dots sealed in liquid-cavity is proposed. The ultraviolet-sensitive region is integrated inside the fiber to avoid interference from external media, and high fluorescence conversion efficiency and ultra-compact structure are achieved due to the high fluorescence quantum efficiency and excellent luminescence stability of CdZnSe/ZnSe/ZnS quantum dots solution. The temperature crosstalk problem of semiconductor materials applied to sensors is solved in this single structure by monitoring of peak wavelength and intensity of fluorescence spectra simultaneously to achieve the temperature compensation function of the sensor. The results show linear dependence of UV sensitivity on temperature which is able to be demodulated through peak wavelength individually. In addition, the quantum dots sealed in liquid-cavity protected by hollow core fiber can resist corrosion, high pressure, and electromagnetic interference, providing a new idea for UV detection in harsh environments.
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (6) , 2193-2199
Horizontal Clinometer Based on a Movable Bubble in the Arc-Shaped Quantum Dots Liquid Cavity
In this paper, we proposed an ultracompact horizontal clinometer based on a movable bubble in the arc-shaped quantum dots (QDs) liquid cavity. The bubble which can move and rest at the arc-shaped inner wall of the liquid cavity enables the structure to be used for sensing of the tilt angle. The experimental results show that the sensor reveals the good response with the quadratic fitting between fluorescence intensities and tilt angles because the bubble blocks the excitation light in two ways, is further verified by theoretical analysis. And the sensor can distinguish the tilt direction via fluorescence intensity. The sensor also shows excellent repeatability and stability. Besides, this kind of horizontal clinometer based on the principle of fluorescence intensity demodulation has the advantages of convenient demodulation, miniaturization and low cost.
- 26 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Journal of Lightwave Technology
- Vol. 42 (6) , 2193-2199
Horizontal Clinometer Based on a Movable Bubble in the Arc-Shaped Quantum Dots Liquid Cavity
In this paper, we proposed an ultracompact horizontal clinometer based on a movable bubble in the arc-shaped quantum dots (QDs) liquid cavity. The bubble which can move and rest at the arc-shaped inner wall of the liquid cavity enables the structure to be used for sensing of the tilt angle. The experimental results show that the sensor reveals the good response with the quadratic fitting between fluorescence intensities and tilt angles because the bubble blocks the excitation light in two ways, is further verified by theoretical analysis. And the sensor can distinguish the tilt direction via fluorescence intensity. The sensor also shows excellent repeatability and stability. Besides, this kind of horizontal clinometer based on the principle of fluorescence intensity demodulation has the advantages of convenient demodulation, miniaturization and low cost.
- 3 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Ultra-Sensitive Optical Fiber Humidity Sensor via Au-Film-Assisted Polyvinyl Alcohol Micro-Cavity and Vernier Effect
To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.
- 3 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Ultra-Sensitive Optical Fiber Humidity Sensor via Au-Film-Assisted Polyvinyl Alcohol Micro-Cavity and Vernier Effect
To enhance humidity sensitivity, a parallel Fabry–Perot interferometer (FPI)-based Vernier scheme is theoretically and experimentally developed via the parallel and separated micro-cavities of polyvinyl alcohol (PVA) and hollow core fiber (HCF). Through Au-film assistance and fine attenuation adjustment, the matched light energy of micro-cavities is obtained and high-contrast envelope with ~11-fold improvement is demonstrated within the 200-nm range. Centering the $\sim 77~\mu \text{m}$ length Au-PVA micro-cavity, the comprehensive tests in terms of humidity are conducted. The experimental results show that, owing to the magnification of Vernier effect, ultra-sensitive humidity response of −9.14 nm/%RH is gained. And the crosstalk of temperature is constrained within −0.0843%RH/°C. In addition, 0.505 s dynamic time-response is verified through field tests of breathing. With the merits of stability, compact size, and ease of operation, our scheme is very practical and has potential in the applications of humidity-related biochemical sensing and medical health monitoring.