Fan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fan Wang has a total of 52 co-authors. Here are the top co-authors by number of shared publications:
Suna Guo
5 shared publications- Lide Fang
School of Quality and Technical Supervision, Hebei University, Baoding, China
4 shared publications Baohui Wang
School of Quality and Technical Supervision Hebei University Baoding Hebei China
2 shared publicationsJiawen Han
2 shared publications- Ning Zhao
School of Quality and Technical Supervision, Hebei University 1 , Baoding 071000
2 shared publications Qianhui Wang
2 shared publications
Latest Publications
- 13 March 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 110
Design of turbine flowmeter for non-fully developed flow fields
- 13 March 2026
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 110
Design of turbine flowmeter for non-fully developed flow fields
- 17 September 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 107
Dynamic performance analysis of Coriolis mass flowmeter
- 17 September 2025
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 107
Dynamic performance analysis of Coriolis mass flowmeter
- 14 April 2025
- Published by Elsevier in Measurement
- Vol. 253
Interfacial wave parameters measurement based on flow noise decoupling in horizontal annular flow
- 14 April 2025
- Published by Elsevier in Measurement
- Vol. 253
Interfacial wave parameters measurement based on flow noise decoupling in horizontal annular flow
- 25 September 2024
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 100
Performance compensation model of turbine flowmeter under vibration conditions
- 25 September 2024
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 100
Performance compensation model of turbine flowmeter under vibration conditions
- 7 September 2024
- Published by Elsevier in Measurement
- Vol. 241
Analysis of turbine flowmeter’s performance under vibration condition
- 7 September 2024
- Published by Elsevier in Measurement
- Vol. 241
Analysis of turbine flowmeter’s performance under vibration condition
- 5 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115303
An adaptive weighted integration method for multipath ultrasonic flowmeter
The error introduced by the integration method is an important factor affecting the measurement accuracy of the multipath ultrasonic flowmeter. An adaptive weighted integration method (adaptive weighted integration method for velocity profile of circular section) is proposed to reduce the integration error, taking a DN400 double-side eight-path ultrasonic flowmeter as an example. This method is based on the velocity distribution information in the full flow range and the integration weights are determined by the principle of minimum error. The applicability of this method is verified by numerical simulation and actual fluid flow experiments. The results show that the integration error of the proposed method is superior to the Gauss–Jacobi and optimized weighted integration method for circular section integration methods, and the maximum integration error is reduced from 0.0877% and −0.0355% to 0.0220% in the flow range of 125–2500 t h−1.
- 5 August 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (11) , 115303
An adaptive weighted integration method for multipath ultrasonic flowmeter
The error introduced by the integration method is an important factor affecting the measurement accuracy of the multipath ultrasonic flowmeter. An adaptive weighted integration method (adaptive weighted integration method for velocity profile of circular section) is proposed to reduce the integration error, taking a DN400 double-side eight-path ultrasonic flowmeter as an example. This method is based on the velocity distribution information in the full flow range and the integration weights are determined by the principle of minimum error. The applicability of this method is verified by numerical simulation and actual fluid flow experiments. The results show that the integration error of the proposed method is superior to the Gauss–Jacobi and optimized weighted integration method for circular section integration methods, and the maximum integration error is reduced from 0.0877% and −0.0355% to 0.0220% in the flow range of 125–2500 t h−1.
- 29 July 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (10) , e3856
Computational model‐based hemodynamic comparisons of traditional and modified idealized models of autologous radiocephalic fistula
Autologous arteriovenous fistula (AVF) is a commonly used vascular access (VA) for hemodialysis, and hemodynamic changes are one of the main factors for its failure. To explore the effect of geometry on the hemodynamics in the AVF, a modified model is built with a gradual and smooth turn at the anastomosis and is compared with the traditional model, which has an abrupt sharp turn at the anastomisis. Transient computational fluid dynamics (CFD) simulations were performed for the comparison and analysis of the hemodynamic fields of the two models at different stages of the pulse cycle. The results showed that the low shear stress region and high oscillatory shear stress region in the modified AVF model coincided with regions of intimal hyperplasia that have been identified by previous studies. A comparison with the blood flow velocities measured in vivo was performed, and the error between the simulation results and the medical data was reduced by 22% in the modified model, which verifies the rationality and utility of the modified model.
- 29 July 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (10) , e3856
Computational model‐based hemodynamic comparisons of traditional and modified idealized models of autologous radiocephalic fistula
Autologous arteriovenous fistula (AVF) is a commonly used vascular access (VA) for hemodialysis, and hemodynamic changes are one of the main factors for its failure. To explore the effect of geometry on the hemodynamics in the AVF, a modified model is built with a gradual and smooth turn at the anastomosis and is compared with the traditional model, which has an abrupt sharp turn at the anastomisis. Transient computational fluid dynamics (CFD) simulations were performed for the comparison and analysis of the hemodynamic fields of the two models at different stages of the pulse cycle. The results showed that the low shear stress region and high oscillatory shear stress region in the modified AVF model coincided with regions of intimal hyperplasia that have been identified by previous studies. A comparison with the blood flow velocities measured in vivo was performed, and the error between the simulation results and the medical data was reduced by 22% in the modified model, which verifies the rationality and utility of the modified model.
- 3 March 2024
- Published by Elsevier in Measurement
- Vol. 229
Measurement and analysis of void fraction in horizontal plug flow based on electromagnetic wave sensor
- 3 March 2024
- Published by Elsevier in Measurement
- Vol. 229
Measurement and analysis of void fraction in horizontal plug flow based on electromagnetic wave sensor
- 30 September 2023
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 94
Structural optimization of microchannel array sensor for stabilizing fluid flow
- 30 September 2023
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 94
Structural optimization of microchannel array sensor for stabilizing fluid flow