Saman Sotoudeh-Paima
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Saman Sotoudeh-Paima has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Ehsan Abadi
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
5 shared publications - Ehsan Samei
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University School of Medicine, 2424 Erwin Rd, Hock Plaza, Ste 302, Durham, NC 27705
5 shared publications - David A. Lynch
Department of Radiology, National Jewish Health, Denver, Colo
3 shared publications - Stephen M. Humphries
Department of Radiology, National Jewish Health, Denver, Colo
2 shared publications - Amar Kavuri
Center for Virtual Imaging Trials, Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University, Durham, North Carolina (A.K., W.P.S., H.P.M., E.S., E.A.).
1 shared publication - Andres F. Abadia
NAM CT R&D Collaborations, Siemens Medical Solutions, Malvern, Pa
1 shared publication
Latest Publications
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (6)
Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study
In this multi-institutional, multiphantom study, photon-counting detector CT provided more accurate and reproducible lung densitometry while maintaining comparability with energy-integrating detector CT protocols.
- 1 December 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (6)
Reproducibility of Lung Densitometry with Photon-counting Detector and Energy-integrating Detector CT: A Multi-Institutional Phantom Study
In this multi-institutional, multiphantom study, photon-counting detector CT provided more accurate and reproducible lung densitometry while maintaining comparability with energy-integrating detector CT protocols.
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (2) , e250124
Precise Lung Density Quantification with a Physics-based CT Harmonizer
A physics-based image harmonization method was developed and validated; it improved CT-based lung density reproducibility by aligning images to a reference quality index of noise, resolution, and lung volume.
- 1 April 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 8 (2) , e250124
Precise Lung Density Quantification with a Physics-based CT Harmonizer
A physics-based image harmonization method was developed and validated; it improved CT-based lung density reproducibility by aligning images to a reference quality index of noise, resolution, and lung volume.
- 10 May 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1890-1898
Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study
Objectives: To evaluate how photon-counting CT (PCCT) reproducibly quantifies lung density compared to conventional CT (energy-integrating CT or EICT) and assess the relevance of image quality. Methods: In this retrospective analysis of a prospective study, subjects underwent acquisitions using EICT and PCCT systems (August-December 2021) on the same day. PCCT projections were reconstructed with 4 kernels and 2 voxel sizes using 2024 reconstruction software (ReconCT, Siemens). PCCT and EICT data were compared using lung density measurements: percentage of low-attenuation areas <−950 Hounsfield unit (HU) (LAA-950), 15th percentile of lung density histogram (Perc15), and mean lung density (MLD). Measurement reproducibility and its relation to image quality parameters (modulation transfer function and noise) were analyzed. Results: Fifty-four subjects (mean age, 67.4 years ± 9.6, 30 female) were studied. PCCT images had the closest agreement to EICT under identical voxel size and similar kernels, yielding lower LAA-950 (−0.9% ± 2.7, P < 0.05), higher Perc15 (1.4 HU ± 7.9, P > 0.05), and higher MLD (2.4 HU ± 10.8, P > 0.05). At higher PCCT resolution (1024 × 1024 matrix, 0.2 mm slice thickness), the smoother quantitative kernel (Qr36) improved agreement, with differences of −0.5% ± 3.0, −0.1 HU ± 9.8, and 2.8 HU ± 11.1, for LAA-950, Perc15, and MLD (P > 0.05). Image quality parameters strongly correlated with density measurements (RPerc152=85.3%). Conclusions: PCCT yields reproducible lung density measurements comparable to EICT, with optimal reproducibility dependent on optimized reconstruction parameters and explainable by image quality parameters. Advances in knowledge: Lung density reproducibility is critical for integrating PCCT into EICT-based workflows. In our study, PCCT aligned more closely with EICT using similar kernels at identical voxel sizes, or smoother kernels at smaller voxel sizes.
- 10 May 2025
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 98 (1175) , 1890-1898
Reproducibility of lung density quantification across photon-counting and conventional energy-integrating CT: a comparative study
Objectives: To evaluate how photon-counting CT (PCCT) reproducibly quantifies lung density compared to conventional CT (energy-integrating CT or EICT) and assess the relevance of image quality. Methods: In this retrospective analysis of a prospective study, subjects underwent acquisitions using EICT and PCCT systems (August-December 2021) on the same day. PCCT projections were reconstructed with 4 kernels and 2 voxel sizes using 2024 reconstruction software (ReconCT, Siemens). PCCT and EICT data were compared using lung density measurements: percentage of low-attenuation areas <−950 Hounsfield unit (HU) (LAA-950), 15th percentile of lung density histogram (Perc15), and mean lung density (MLD). Measurement reproducibility and its relation to image quality parameters (modulation transfer function and noise) were analyzed. Results: Fifty-four subjects (mean age, 67.4 years ± 9.6, 30 female) were studied. PCCT images had the closest agreement to EICT under identical voxel size and similar kernels, yielding lower LAA-950 (−0.9% ± 2.7, P < 0.05), higher Perc15 (1.4 HU ± 7.9, P > 0.05), and higher MLD (2.4 HU ± 10.8, P > 0.05). At higher PCCT resolution (1024 × 1024 matrix, 0.2 mm slice thickness), the smoother quantitative kernel (Qr36) improved agreement, with differences of −0.5% ± 3.0, −0.1 HU ± 9.8, and 2.8 HU ± 11.1, for LAA-950, Perc15, and MLD (P > 0.05). Image quality parameters strongly correlated with density measurements (RPerc152=85.3%). Conclusions: PCCT yields reproducible lung density measurements comparable to EICT, with optimal reproducibility dependent on optimized reconstruction parameters and explainable by image quality parameters. Advances in knowledge: Lung density reproducibility is critical for integrating PCCT into EICT-based workflows. In our study, PCCT aligned more closely with EICT using similar kernels at identical voxel sizes, or smoother kernels at smaller voxel sizes.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (12) , 3494-3504
A Physics-Informed Deep Neural Network for Harmonization of CT Images
Computed Tomography (CT) quantification is affected by the variability in image acquisition and rendition. This paper aimed to reduce this variability by harmonizing the images utilizing physics-based deep neural networks (DNNs). Methods: An adversarial generative network was trained on virtual CT images acquired under various imaging conditions using a virtual imaging platform with 40 computational patient models. These models featured anthropomorphic lungs with different levels of pulmonary diseases, including nodules and emphysema. Imaging was conducted using a validated CT simulator at two dose levels and varying reconstruction kernels. The trained model was tested on an independent virtual test dataset and two clinical datasets. Results: On the virtual test set, the harmonizer improved the structural similarity index from 79.3 $\pm$ 16.4% to 95.8 $\pm$ 1.7%, normalized mean squared error from 16.7 $\pm$ 9.7% to 9.2 $\pm$ 1.7%, and peak signal-to-noise ratio from 27.7 $\pm$ 3.7 dB to 32.2 $\pm$ 1.6 dB. Moreover, the harmonized images yielded more precise quantification of emphysema-based imaging biomarkers for lung attenuation, LAA -950 from 5.6 $\pm$ 8.7% to 0.23 $\pm$ 0.16%, Perc 15 from 43.4 $\pm$ 45.4 HU to 20.0 $\pm$ 7.5 HU, and Lung Mass from 0.3 $\pm$ 0.3 g to 0.1 $\pm$ 0.2 g. In clinical data, the harmonizer reduced biomarker variability by an average of 70%. For lung nodules, harmonized images improved the detectability index by 6.5-fold and DNN-based precision by 6%. Conclusion: The proposed harmonizer significantly enhances image quality and quantification accuracy in CT imaging. Significance: The study demonstrated the potential utility of image harmonization for consistent CT image quality and reliable quantification, which is crucial for clinical applications and patient management.
- 16 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 71 (12) , 3494-3504
A Physics-Informed Deep Neural Network for Harmonization of CT Images
Computed Tomography (CT) quantification is affected by the variability in image acquisition and rendition. This paper aimed to reduce this variability by harmonizing the images utilizing physics-based deep neural networks (DNNs). Methods: An adversarial generative network was trained on virtual CT images acquired under various imaging conditions using a virtual imaging platform with 40 computational patient models. These models featured anthropomorphic lungs with different levels of pulmonary diseases, including nodules and emphysema. Imaging was conducted using a validated CT simulator at two dose levels and varying reconstruction kernels. The trained model was tested on an independent virtual test dataset and two clinical datasets. Results: On the virtual test set, the harmonizer improved the structural similarity index from 79.3 $\pm$ 16.4% to 95.8 $\pm$ 1.7%, normalized mean squared error from 16.7 $\pm$ 9.7% to 9.2 $\pm$ 1.7%, and peak signal-to-noise ratio from 27.7 $\pm$ 3.7 dB to 32.2 $\pm$ 1.6 dB. Moreover, the harmonized images yielded more precise quantification of emphysema-based imaging biomarkers for lung attenuation, LAA -950 from 5.6 $\pm$ 8.7% to 0.23 $\pm$ 0.16%, Perc 15 from 43.4 $\pm$ 45.4 HU to 20.0 $\pm$ 7.5 HU, and Lung Mass from 0.3 $\pm$ 0.3 g to 0.1 $\pm$ 0.2 g. In clinical data, the harmonizer reduced biomarker variability by an average of 70%. For lung nodules, harmonized images improved the detectability index by 6.5-fold and DNN-based precision by 6%. Conclusion: The proposed harmonizer significantly enhances image quality and quantification accuracy in CT imaging. Significance: The study demonstrated the potential utility of image harmonization for consistent CT image quality and reliable quantification, which is crucial for clinical applications and patient management.
- Top Cited Papers
- 2 March 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105368
Multi-scale convolutional neural network for automated AMD classification using retinal OCT images
- 2 March 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 144, 105368
Top Cited PapersMulti-scale convolutional neural network for automated AMD classification using retinal OCT images