Tiril Aurora Lintvedt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Tiril Aurora Lintvedt has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Nils Kristian Afseth
Raw Materials and Process Optimization Norwegian Institute for Food, Fisheries and Aquaculture Research Tromsø Norway
6 shared publications- Jens Petter Wold
Norwegian Institute for Food, Fisheries and Aquaculture Research, Muninbakken 9-13, Breivika, Tromsø, 9291, Norway
4 shared publications - Petter Vejle Andersen
Norwegian Institute for Food, Fisheries and Aquaculture Research, Muninbakken 9-13, Breivika, Tromsø, 9291, Norway
4 shared publications Jens Petter Wold
Raw Materials and Process Optimization Norwegian Institute for Food, Fisheries and Aquaculture Research Tromsø Norway
3 shared publications- Achim Kohler
Faculty of Science and Technology, Norwegian University of Life Sciences, Ås, Norway
1 shared publication - Anna Jofré
Food Safety and Functionality Program, Institute of Agrifood Research and Technology (IRTA), Finca Camps i Armet, 17121 Monells, Spain
1 shared publication
Latest Publications
- Open Access
- 24 April 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (8) , 1325-1338
Managing Spectral Intensity Variations With In‐Line Fiber‐Optic High‐Volume Noncontact Raman Probes: A Strategy Exploration
Noncontact fiber-optic Raman probes are increasingly deployed in industrial environments, where variations in laser power and working distance can compromise quantitative performance. We investigated the stability of partial least squares regression under combined changes in laser power (200–450 mW) and working distance (5–30 cm), comparing intensity-correction strategies that preserve absolute intensity related to absolute concentration with approaches that suppress it. The effect was discussed in terms of absolute fat concentration measurements and compared with the relative concentration measurement of fatty acid (FA) 18:1 expressed as % of fat. Overall, both correction strategies yielded comparable slope and variance errors, with bias emerging as the primary distinction. Laser power fluctuations were effectively corrected using sapphire-based normalization or other methods suppressing intensity variations ( and ). Working distance effects were nonlinear and required dedicated compensation. We demonstrated the potential of using nitrogen signals from the air for working distance corrections in bulk fat measurements ( ). For FA 18:1, accurate quantification depended on explicit removal of instrument and air background, and only an extended multiplicative scatter correction (EMSC) including both background components as separate interferents achieved acceptable bias, providing , compared with for MSC. These results outline practical strategies for maintaining quantitative robustness in noncontact Raman measurements under realistic industrial variability.- 24 April 2026
- Published by Wiley in Journal of Raman Spectroscopy
- Vol. 57 (8) , 1325-1338
Open AccessManaging Spectral Intensity Variations With In‐Line Fiber‐Optic High‐Volume Noncontact Raman Probes: A Strategy Exploration
Noncontact fiber-optic Raman probes are increasingly deployed in industrial environments, where variations in laser power and working distance can compromise quantitative performance. We investigated the stability of partial least squares regression under combined changes in laser power (200–450 mW) and working distance (5–30 cm), comparing intensity-correction strategies that preserve absolute intensity related to absolute concentration with approaches that suppress it. The effect was discussed in terms of absolute fat concentration measurements and compared with the relative concentration measurement of fatty acid (FA) 18:1 expressed as % of fat. Overall, both correction strategies yielded comparable slope and variance errors, with bias emerging as the primary distinction. Laser power fluctuations were effectively corrected using sapphire-based normalization or other methods suppressing intensity variations ( and ). Working distance effects were nonlinear and required dedicated compensation. We demonstrated the potential of using nitrogen signals from the air for working distance corrections in bulk fat measurements ( ). For FA 18:1, accurate quantification depended on explicit removal of instrument and air background, and only an extended multiplicative scatter correction (EMSC) including both background components as separate interferents achieved acceptable bias, providing , compared with for MSC. These results outline practical strategies for maintaining quantitative robustness in noncontact Raman measurements under realistic industrial variability. - Open Access
- 1 October 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1379, 344658
Raman and NIR spectroscopy: A discussion of calibration robustness for food quality measurements through two case studies
- 1 October 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1379, 344658
Open AccessRaman and NIR spectroscopy: A discussion of calibration robustness for food quality measurements through two case studies
- Open Access
- 7 June 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 343, 126463
Discrimination of normal and wooden breast chicken fillets using NIR, fluorescence and Raman spectroscopy
- 7 June 2025
- Published by Elsevier in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
- Vol. 343, 126463
Open AccessDiscrimination of normal and wooden breast chicken fillets using NIR, fluorescence and Raman spectroscopy
- Open Access
- 8 November 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1284, 342005
The role of biospectroscopy and chemometrics as enabling technologies for upcycling of raw materials from the food industry
- 8 November 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1284, 342005
Open AccessThe role of biospectroscopy and chemometrics as enabling technologies for upcycling of raw materials from the food industry
- Open Access
In-line Raman spectroscopy for characterization of an industrial poultry raw material stream
- Open Access
- 25 February 2022
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 76 (5) , 559-568
Feasibility of In-Line Raman Spectroscopy for Quality Assessment in Food Industry: How Fast Can We Go?
Raman spectroscopy is a viable tool within process analytical technologies due to recent technological advances. In this article, we evaluate the feasibility of Raman spectroscopy for in-line applications in the food industry by estimating the concentration of the fatty acids EPA + DHA in ground salmon samples (n = 63) and residual bone concentration in samples of mechanically recovered ground chicken (n = 66). The samples were measured under industry like conditions: They moved on a conveyor belt through a dark cabinet where they were scanned with a wide area illumination standoff Raman probe. Such a setup should be able to handle relevant industrial conveyor belt speeds, and it was studied how different speeds (i.e., exposure times) influenced the signal-to-noise ratio (SNR) of the Raman spectra as well as the corresponding model performance. For all samples we applied speeds that resulted in 1 s, 2 s, 4 s, and 10 s exposure times. Samples were scanned in both heterogenous and homogenous state. The slowest speed (10 s exposure) yielded prediction errors (RMSECV) of 0.41%EPA + DHA and 0.59% ash for the salmon and chicken data sets, respectively. The more in-line relevant exposure time of 1 s resulted in increased RMSECV values, 0.84% EPA + DHA and 0.84% ash, respectively. The increase in prediction error correlated closely with the decrease in SNR. Further improvements of model performance were possible through different noise reduction strategies. Model performance for homogenous and heterogenous samples was similar, suggesting that the presented Raman scanning approach has the potential to work well also on intact heterogenous foods. The estimation errors obtained at these high speeds are likely acceptable for industrial use, but successful strategies to increase SNR will be key for widespread in-line use in the food industry.
- 25 February 2022
- Published by SAGE Publications in Applied Spectroscopy
- Vol. 76 (5) , 559-568
Open AccessFeasibility of In-Line Raman Spectroscopy for Quality Assessment in Food Industry: How Fast Can We Go?
Raman spectroscopy is a viable tool within process analytical technologies due to recent technological advances. In this article, we evaluate the feasibility of Raman spectroscopy for in-line applications in the food industry by estimating the concentration of the fatty acids EPA + DHA in ground salmon samples (n = 63) and residual bone concentration in samples of mechanically recovered ground chicken (n = 66). The samples were measured under industry like conditions: They moved on a conveyor belt through a dark cabinet where they were scanned with a wide area illumination standoff Raman probe. Such a setup should be able to handle relevant industrial conveyor belt speeds, and it was studied how different speeds (i.e., exposure times) influenced the signal-to-noise ratio (SNR) of the Raman spectra as well as the corresponding model performance. For all samples we applied speeds that resulted in 1 s, 2 s, 4 s, and 10 s exposure times. Samples were scanned in both heterogenous and homogenous state. The slowest speed (10 s exposure) yielded prediction errors (RMSECV) of 0.41%EPA + DHA and 0.59% ash for the salmon and chicken data sets, respectively. The more in-line relevant exposure time of 1 s resulted in increased RMSECV values, 0.84% EPA + DHA and 0.84% ash, respectively. The increase in prediction error correlated closely with the decrease in SNR. Further improvements of model performance were possible through different noise reduction strategies. Model performance for homogenous and heterogenous samples was similar, suggesting that the presented Raman scanning approach has the potential to work well also on intact heterogenous foods. The estimation errors obtained at these high speeds are likely acceptable for industrial use, but successful strategies to increase SNR will be key for widespread in-line use in the food industry.
- Open Access
Preprocessing Strategies for Sparse Infrared Spectroscopy: A Case Study on Cartilage Diagnostics
The aim of the study was to optimize preprocessing of sparse infrared spectral data. The sparse data were obtained by reducing broadband Fourier transform infrared attenuated total reflectance spectra of bovine and human cartilage, as well as of simulated spectral data, comprising several thousand spectral variables into datasets comprising only seven spectral variables. Different preprocessing approaches were compared, including simple baseline correction and normalization procedures, and model-based preprocessing, such as multiplicative signal correction (MSC). The optimal preprocessing was selected based on the quality of classification models established by partial least squares discriminant analysis for discriminating healthy and damaged cartilage samples. The best results for the sparse data were obtained by preprocessing using a baseline offset correction at 1800 cm−1, followed by peak normalization at 850 cm−1 and preprocessing by MSC.
Open AccessPreprocessing Strategies for Sparse Infrared Spectroscopy: A Case Study on Cartilage Diagnostics
The aim of the study was to optimize preprocessing of sparse infrared spectral data. The sparse data were obtained by reducing broadband Fourier transform infrared attenuated total reflectance spectra of bovine and human cartilage, as well as of simulated spectral data, comprising several thousand spectral variables into datasets comprising only seven spectral variables. Different preprocessing approaches were compared, including simple baseline correction and normalization procedures, and model-based preprocessing, such as multiplicative signal correction (MSC). The optimal preprocessing was selected based on the quality of classification models established by partial least squares discriminant analysis for discriminating healthy and damaged cartilage samples. The best results for the sparse data were obtained by preprocessing using a baseline offset correction at 1800 cm−1, followed by peak normalization at 850 cm−1 and preprocessing by MSC.