Janusch Walaschek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Janusch Walaschek has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Caterina Gregorio
Aging Research Center, Department of Neurobiology, Care Sciences and Society, Karolinska Institutet and Stockholm University, Stockholm, Sweden
1 shared publication - Dirk Bastian
Medizinische Klinik I, Klinikum Fürth, Academic Teaching Hospital of the Friedrich-Alexander-University Erlangen-Nürnberg , Jakob-Henle-Str. 1, Fürth 90766
1 shared publication - Harald Rittger
Department of Cardiology and Pulmonology, Hospital Fürth, Fürth, Germany
1 shared publication - Laura Vitali-Serdoz
Clinic Fuerth , Fuerth , Germany
1 shared publication - Veronica Buia
Clinic Fuerth , Fuerth , Germany
1 shared publication
Latest Publications
- Open Access
- 4 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
His bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes
Pace mapping and visual comparison of the local pacing response with the intrinsic QRS morphology form the mainstay of His bundle pacing (HBP). We evaluated the performance of a surface lead morphology match algorithm for automated classification of the pacing response in patients with narrow intrinsic QRS undergoing electroanatomic mapping (EAM)-guided HBP. HBP was attempted in 43 patients. In 28 cases with narrow QRS, the EnSite AutoMap Module was used for automated assessment of the QRS morphology resulting from pace mapping in the His cloud area with either a diagnostic catheter or the His lead. An intrinsic morphology match score (IMS) was calculated for 1.546 QRS complexes and assessed regarding its accuracy and performance in classifying the individual pacing response as either selective HBP (S-HBP), nonselective HBP (NS-HBP) or right ventricular stimulation. Automated morphology comparison of 354 intrinsic beats with the individual reference determined a test accuracy of 99% (95% CI 98.96–99.04) and a precision of 97.99–99.5%. For His-lead stimulation, an IMS ≥ 89% identified S-HBP with a sensitivity, specificity and positive predictive value of 1.00 (0.99, 1.00) and a negative predictive value of 0.99 (0.98, 1.00). An IMS between 78 and < 89% indicated NS-HBP with a sensitivity and specificity of 1.00 (0.99, 1.00) and 0.99 (0.98, 1.00), respectively. IMS represents a new automated measure for standardized individual morphology classification in patients with normal QRS undergoing EAM-guided HBP.Clinical trial registration: NCT04416958.
- 4 March 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-12
Open AccessHis bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes
Pace mapping and visual comparison of the local pacing response with the intrinsic QRS morphology form the mainstay of His bundle pacing (HBP). We evaluated the performance of a surface lead morphology match algorithm for automated classification of the pacing response in patients with narrow intrinsic QRS undergoing electroanatomic mapping (EAM)-guided HBP. HBP was attempted in 43 patients. In 28 cases with narrow QRS, the EnSite AutoMap Module was used for automated assessment of the QRS morphology resulting from pace mapping in the His cloud area with either a diagnostic catheter or the His lead. An intrinsic morphology match score (IMS) was calculated for 1.546 QRS complexes and assessed regarding its accuracy and performance in classifying the individual pacing response as either selective HBP (S-HBP), nonselective HBP (NS-HBP) or right ventricular stimulation. Automated morphology comparison of 354 intrinsic beats with the individual reference determined a test accuracy of 99% (95% CI 98.96–99.04) and a precision of 97.99–99.5%. For His-lead stimulation, an IMS ≥ 89% identified S-HBP with a sensitivity, specificity and positive predictive value of 1.00 (0.99, 1.00) and a negative predictive value of 0.99 (0.98, 1.00). An IMS between 78 and < 89% indicated NS-HBP with a sensitivity and specificity of 1.00 (0.99, 1.00) and 0.99 (0.98, 1.00), respectively. IMS represents a new automated measure for standardized individual morphology classification in patients with normal QRS undergoing EAM-guided HBP.Clinical trial registration: NCT04416958.