Gema Romadhona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Gema Romadhona has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Annisa Gallela Anjani
Department of Electromedical Engineering, Universitas Muhammadiyah Purwokerto
1 shared publicationArif Mulyanto
Department of Medical Laboratory Technology, Universitas Muhammadiyah Purwokerto
1 shared publication- Iwan Setiawan
Diponegoro University
1 shared publication Jumrianto Jumrianto
Faculty of Science and Technology, IVET University
1 shared publication- Ketut Ima Ismara
Universitas Negeri Yogyakarta
1 shared publication - Kusnanto Mukti Wibowo
Department of Medical Electronics Engineering Technology, Universitas Muhammadiyah Purwokerto, Purwokerto, Indonesia, Indonesia
1 shared publication
Latest Publications
- Open Access
- 6 February 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (1) , 23-27
Application of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety
Nowadays, health care has turned out to be more technology-oriented. Today's technology is demanded to be practical and easy to use. The number of mobile devices based on the Android operating system has increased significantly based on data. The open-source nature of android helps in programming applications easily according to user requirements. The syringe pump is a medical device that functions to enter the medicinal fluid into the patient's body at a specific dose and time automatically in mL/hour. The syringe pump is generally equipped with an alarm. Alarms have a vital function to provide information to nurses or doctors on duty. Medical officers cannot hear alarms outside the patient monitoring room. This paper aims to design a syringe pump that is equipped with a NodeMCU8266 WiFi module to provide notifications via a smartphone so that nurses or doctors can know the alarm even though they are outside the patient monitoring room. So, this is expected can improve patient safety. In addition, this paper also aims to verify the size of the syringe against the drug flow rate. Based on the test results, the syringe pump can control the drug flow rate with a sensor accuracy of 0.0217 and an error rate of 0.6% at a target volume of 5mL. The syringe pump can also send alarm notifications to smartphones in real-time.
- 6 February 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (1) , 23-27
Open AccessApplication of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety
Nowadays, health care has turned out to be more technology-oriented. Today's technology is demanded to be practical and easy to use. The number of mobile devices based on the Android operating system has increased significantly based on data. The open-source nature of android helps in programming applications easily according to user requirements. The syringe pump is a medical device that functions to enter the medicinal fluid into the patient's body at a specific dose and time automatically in mL/hour. The syringe pump is generally equipped with an alarm. Alarms have a vital function to provide information to nurses or doctors on duty. Medical officers cannot hear alarms outside the patient monitoring room. This paper aims to design a syringe pump that is equipped with a NodeMCU8266 WiFi module to provide notifications via a smartphone so that nurses or doctors can know the alarm even though they are outside the patient monitoring room. So, this is expected can improve patient safety. In addition, this paper also aims to verify the size of the syringe against the drug flow rate. Based on the test results, the syringe pump can control the drug flow rate with a sensor accuracy of 0.0217 and an error rate of 0.6% at a target volume of 5mL. The syringe pump can also send alarm notifications to smartphones in real-time.