Kusnanto Mukti Wibowo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kusnanto Mukti Wibowo has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Mohd Zainizan Sahdan
Universiti Tun Hussein Onn Malaysia
5 shared publications - Hashim Saim
Universiti Tun Hussein Onn Malaysia
3 shared publications - Nafarizal Nayan
Faculty of Electrical and Electronic Engineering Universiti Tun Hussein Onn Malaysia 86400 Johor Malaysia
3 shared publications A. Muslihati
Microelectronics and Nanotechnology Shamsuddin Research Center (MiNT-SRC), Universiti Tun Hussien Onn Malaysia (UTHM), 86400, Johor, Malaysia
2 shared publications- Arga Pratama Rahardian
Departement of Radiology Imaging Technology, Universitas Muhammadiyah Purwokerto, Banyumas, Indonesia, Indonesia
2 shared publications - Che Ani Norhidayah
Universiti Tun Hussein Onn Malaysia
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 19 (2) , 084-092
Experimental Study on Thickness-Dependent X-ray Radiation Protection of a Flexible and Lightweight Silicone Rubber–PbO Composite Apron
The use of X-rays in medical imaging provides substantial diagnostic benefits but also poses risks associated with ionizing radiation exposure. Conventional lead-based protective aprons are effective but have major limitations, including excessive weight, rigidity, and potential toxicity. This study addresses a specific research gap by systematically evaluating the relationship between material thickness, radiation attenuation effectiveness, and the Half-Value Layer (HVL) of silicone rubber-based aprons filled with lead(II) oxide (PbO) at clinically relevant low-to-medium X-ray energies. An experimental method was employed by fabricating silicone–PbO composite apron prototypes with three thickness variations (2.5 mm, 3.0 mm, and 3.5 mm). Radiation attenuation tests were conducted at X-ray tube voltages of 60, 65, and 70 kV by measuring radiation intensity before and after transmission through the samples using a radiation detector, followed by calculating protection effectiveness and HVL values. The results demonstrate that apron thickness significantly influences radiation protection performance, with the highest attenuation of 85.11% achieved at a thickness of 3.5 mm. A moderate-to-strong positive correlation between thickness and protection effectiveness is observed at all voltage levels, with the highest coefficient of determination (R² = 0.916) at 65 kV. HVL values increase with thickness, indicating the need for thicker materials to achieve a 50% reduction in radiation intensity at higher attenuation levels. These findings highlight the novelty of quantitatively correlating thickness, attenuation effectiveness, and HVL within a single experimental framework and demonstrate that silicone rubber–PbO composite aprons have strong potential as a lightweight and flexible alternative to conventional lead aprons for clinical radiation protection at low-to-medium diagnostic X-ray energies.
- 10 April 2026
- Published by Poltekkes Kemenkes Surabaya in Jurnal Teknokes
- Vol. 19 (2) , 084-092
Open AccessExperimental Study on Thickness-Dependent X-ray Radiation Protection of a Flexible and Lightweight Silicone Rubber–PbO Composite Apron
The use of X-rays in medical imaging provides substantial diagnostic benefits but also poses risks associated with ionizing radiation exposure. Conventional lead-based protective aprons are effective but have major limitations, including excessive weight, rigidity, and potential toxicity. This study addresses a specific research gap by systematically evaluating the relationship between material thickness, radiation attenuation effectiveness, and the Half-Value Layer (HVL) of silicone rubber-based aprons filled with lead(II) oxide (PbO) at clinically relevant low-to-medium X-ray energies. An experimental method was employed by fabricating silicone–PbO composite apron prototypes with three thickness variations (2.5 mm, 3.0 mm, and 3.5 mm). Radiation attenuation tests were conducted at X-ray tube voltages of 60, 65, and 70 kV by measuring radiation intensity before and after transmission through the samples using a radiation detector, followed by calculating protection effectiveness and HVL values. The results demonstrate that apron thickness significantly influences radiation protection performance, with the highest attenuation of 85.11% achieved at a thickness of 3.5 mm. A moderate-to-strong positive correlation between thickness and protection effectiveness is observed at all voltage levels, with the highest coefficient of determination (R² = 0.916) at 65 kV. HVL values increase with thickness, indicating the need for thicker materials to achieve a 50% reduction in radiation intensity at higher attenuation levels. These findings highlight the novelty of quantitatively correlating thickness, attenuation effectiveness, and HVL within a single experimental framework and demonstrate that silicone rubber–PbO composite aprons have strong potential as a lightweight and flexible alternative to conventional lead aprons for clinical radiation protection at low-to-medium diagnostic X-ray energies.
- Open Access
- 5 April 2026
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 8 (2) , 275-285
Optimization of Intelligent Grid Strength and Grid Ratio to Improve Pelvic Radiographic Image Quality in Digital Radiography
Pelvic radiography is an essential diagnostic procedure; however, its image quality is often degraded by scattered radiation, which reduces contrast and diagnostic accuracy. Conventional physical grids can reduce scatter but have limitations, including increased patient dose and workflow constraints, particularly in mobile radiography. The Intelligent Grid, a digital scatter correction technology, provides a promising alternative, yet the optimal combination of grid ratio and strength parameters remains unclear. This study aims to optimize the strength and grid ratio of the Intelligent Grid to improve pelvic radiographic image quality. This study introduces a novel quantitative optimization approach that systematically integrates grid ratio and strength variations within the Intelligent Grid system to enhance pelvic radiographic image quality in digital radiography. A quantitative experimental approach with a post-test only design was conducted using a mobile X-ray system, digital radiography, an Aero DR detector, and pelvic phantoms. Data were acquired by performing anteroposterior pelvic radiography exposures (60 kV & 10 mAs) with the Intelligent Grid. Strength variations (slightly strong, normal, slightly weak) and grid ratios (3:1, 6:1, 8:1, 10:1, 12:1) were applied to generate different parameter combinations. Image quality was evaluated quantitatively (histogram and SNR) and qualitatively through visual grading by three radiologists. Statistical analysis was performed using Repeated ANOVA and Friedman tests. Statistical analysis showed significant differences (p < 0.001) in pelvic radiographic image quality across Intelligent Grid ratio and strength combinations. The 12:1 grid ratio with slightly strong strength yielded the highest mean SNR, balanced grayscale distribution, and top visual grading scores, confirming its optimal performance in enhancing image contrast and anatomical visibility of the iliac contour, acetabulum, and pubic symphysis. In conclusion, optimal adjustment of Intelligent Grid strength and grid ratio parameters can substantially improve pelvic radiographic image quality, providing a practical alternative to conventional physical grids in digital radiography
- 5 April 2026
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 8 (2) , 275-285
Open AccessOptimization of Intelligent Grid Strength and Grid Ratio to Improve Pelvic Radiographic Image Quality in Digital Radiography
Pelvic radiography is an essential diagnostic procedure; however, its image quality is often degraded by scattered radiation, which reduces contrast and diagnostic accuracy. Conventional physical grids can reduce scatter but have limitations, including increased patient dose and workflow constraints, particularly in mobile radiography. The Intelligent Grid, a digital scatter correction technology, provides a promising alternative, yet the optimal combination of grid ratio and strength parameters remains unclear. This study aims to optimize the strength and grid ratio of the Intelligent Grid to improve pelvic radiographic image quality. This study introduces a novel quantitative optimization approach that systematically integrates grid ratio and strength variations within the Intelligent Grid system to enhance pelvic radiographic image quality in digital radiography. A quantitative experimental approach with a post-test only design was conducted using a mobile X-ray system, digital radiography, an Aero DR detector, and pelvic phantoms. Data were acquired by performing anteroposterior pelvic radiography exposures (60 kV & 10 mAs) with the Intelligent Grid. Strength variations (slightly strong, normal, slightly weak) and grid ratios (3:1, 6:1, 8:1, 10:1, 12:1) were applied to generate different parameter combinations. Image quality was evaluated quantitatively (histogram and SNR) and qualitatively through visual grading by three radiologists. Statistical analysis was performed using Repeated ANOVA and Friedman tests. Statistical analysis showed significant differences (p < 0.001) in pelvic radiographic image quality across Intelligent Grid ratio and strength combinations. The 12:1 grid ratio with slightly strong strength yielded the highest mean SNR, balanced grayscale distribution, and top visual grading scores, confirming its optimal performance in enhancing image contrast and anatomical visibility of the iliac contour, acetabulum, and pubic symphysis. In conclusion, optimal adjustment of Intelligent Grid strength and grid ratio parameters can substantially improve pelvic radiographic image quality, providing a practical alternative to conventional physical grids in digital radiography
- Open Access
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Analisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen
- 23 December 2025
- Published by Center for Journal Management and Publication, Lambung Mangkurat University in Jurnal Fisika Flux: Jurnal Ilmiah Fisika FMIPA Universitas Lambung Mangkurat
- Vol. 23 (1) , 78
Open AccessAnalisis Korelasi Berat Badan dengan Size Spesific Dose Estimate dan Dosis Efektif pada CT Scan Abdomen
- Open Access
- 2 October 2025
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 7 (4) , 630-640
Development and Acoustic Analysis of a Speaker-Output Stethoscope for Low-Cost Clinical Applications
This study addresses the limitations of traditional stethoscopes, which are constrained by their single-user design, dependence on auditory acuity, and susceptibility to background noise. These limitations hinder collaborative learning and diagnostic accuracy, particularly in noisy environments or during infectious disease outbreaks. The aim of this work is to develop a low-cost, speaker-output digital stethoscope that enables multiple users to simultaneously listen to heart sounds, improving both clinical training and infection control. The main contribution of this study is the integration of a conventional analog stethoscope with a high-sensitivity microphone preamplifier, an external speaker, and digital signal processing (DSP) algorithms. This configuration allows the amplification and filtering of heart sounds, enabling group auscultation without the need for earpieces. The device casing is constructed from High-Pressure Laminate (HPL) sheets and multiplex wood panels, while acoustic foam is used to reduce noise interference. Heart sounds are captured via a microphone, amplified, and processed using Fast Fourier Transform (FFT) and band-pass filtering (20–150 Hz) to isolate the key frequencies. The system was tested in a quiet clinical setting, and the resulting audio was analyzed for clarity and frequency spectrum. The prototype successfully captured heart sounds, with a dominant spectral peak around 97 Hz, consistent with the primary frequency of heartbeats. It also clearly identified the first (S1) and second (S2) heart sounds. However, ambient noise affected sound clarity, indicating the need for further noise reduction. Despite this limitation, the device successfully enabled group auscultation. In conclusion, the speaker-output stethoscope offers an affordable and effective alternative to traditional auscultation, enhancing medical training and improving infection control. Although noise reduction requires further refinement, the system demonstrates strong potential for application in clinical and educational settings, particularly in low-resource environments
- 2 October 2025
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 7 (4) , 630-640
Open AccessDevelopment and Acoustic Analysis of a Speaker-Output Stethoscope for Low-Cost Clinical Applications
This study addresses the limitations of traditional stethoscopes, which are constrained by their single-user design, dependence on auditory acuity, and susceptibility to background noise. These limitations hinder collaborative learning and diagnostic accuracy, particularly in noisy environments or during infectious disease outbreaks. The aim of this work is to develop a low-cost, speaker-output digital stethoscope that enables multiple users to simultaneously listen to heart sounds, improving both clinical training and infection control. The main contribution of this study is the integration of a conventional analog stethoscope with a high-sensitivity microphone preamplifier, an external speaker, and digital signal processing (DSP) algorithms. This configuration allows the amplification and filtering of heart sounds, enabling group auscultation without the need for earpieces. The device casing is constructed from High-Pressure Laminate (HPL) sheets and multiplex wood panels, while acoustic foam is used to reduce noise interference. Heart sounds are captured via a microphone, amplified, and processed using Fast Fourier Transform (FFT) and band-pass filtering (20–150 Hz) to isolate the key frequencies. The system was tested in a quiet clinical setting, and the resulting audio was analyzed for clarity and frequency spectrum. The prototype successfully captured heart sounds, with a dominant spectral peak around 97 Hz, consistent with the primary frequency of heartbeats. It also clearly identified the first (S1) and second (S2) heart sounds. However, ambient noise affected sound clarity, indicating the need for further noise reduction. Despite this limitation, the device successfully enabled group auscultation. In conclusion, the speaker-output stethoscope offers an affordable and effective alternative to traditional auscultation, enhancing medical training and improving infection control. Although noise reduction requires further refinement, the system demonstrates strong potential for application in clinical and educational settings, particularly in low-resource environments
- Open Access
- 17 March 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 77
The Effect of Heat Dissipation by a Concrete Roof and Gypsum Ceiling on the Room Temperature Inside the House
The room temperature that suits the needs will create a comfortable working environment for the occupants. However, an increase in the temperature outside can increase the temperature in the room. Control of heat spread from outside to inside is needed to keep the room temperature stable and avoid significant temperature rises. This study aims to examine the heat dissipation due to the concrete roof and the presence of a gypsum ceiling, and its effect on the temperature of the room below. Methods are applied to this study by making observations to obtain research data. The results showed that heat dissipation by the concrete roof had reduced the indoor temperature to as low as 0.180 °C. The addition of gypsum ceiling under the concrete slab roof at 50 cm has reduced the room temperature by 1.79 °C from the temperature above the roof.
- 17 March 2025
- Published by MDPI AG in Engineering Proceedings
- Vol. 84 (1) , 77
Open AccessThe Effect of Heat Dissipation by a Concrete Roof and Gypsum Ceiling on the Room Temperature Inside the House
The room temperature that suits the needs will create a comfortable working environment for the occupants. However, an increase in the temperature outside can increase the temperature in the room. Control of heat spread from outside to inside is needed to keep the room temperature stable and avoid significant temperature rises. This study aims to examine the heat dissipation due to the concrete roof and the presence of a gypsum ceiling, and its effect on the temperature of the room below. Methods are applied to this study by making observations to obtain research data. The results showed that heat dissipation by the concrete roof had reduced the indoor temperature to as low as 0.180 °C. The addition of gypsum ceiling under the concrete slab roof at 50 cm has reduced the room temperature by 1.79 °C from the temperature above the roof.
- Open Access
- 11 February 2025
- Published by Poltekkes Kemenkes Surabaya in Journal of Electronics, Electromedical Engineering, and Medical Informatics
- Vol. 7 (2) , 270-282
Analysis of Differences in Image Quality and Anatomical Information of Head CT Scan Examination in Non-Hemorrhagic Stroke Cases Using Sinogram Affirmed Iterative Reconstruction (SAFIRE)
SAFIRE should be utilized to its full potential, as this innovative image reconstruction algorithm can significantly reduce image noise without loss of sharpness, preserving image quality and anatomical information. This is particularly important in the case of non-hemorrhagic stroke, where image noise can obscure small lesions, potentially leading to misdiagnosis and inappropriate treatment. SAFIRE has five variations of strength, making it essential to identify the most optimal SAFIRE Strength for head CT Scan examinations in non-hemorrhagic stroke cases. The aim of this study is to determine differences in image quality and anatomical information in head CT Scan of non-hemorrhagic stroke cases using SAFIRE variations to identify the most optimal SAFIRE Strength. This experimental quantitative study involved a sample of 30 patients, with each case reconstructed using five SAFIRE Strength variations. Image quality was assessed using the IndoQCT application, while anatomical information was evaluated through the visual grading analysis method by three radiologists. Image quality data were analyzed using the Friedman statistical test, which resulted in a p-value of 0.000 (p < 0.05), indicating significant differences among the SAFIRE Strength variations. Similarly, anatomical information data were analyzed using the Kruskal-Wallis statistical test, yielding a p-value of 0.000 (p < 0.05), confirming significant differences across the variations. The results of the study showed that there are significant differences in image quality and anatomical information among the five SAFIRE Strength variations. SAFIRE Strength 3 was identified as the most optimal for head CT Scan examinations in non-hemorrhagic stroke cases, as it produces images with minimal noise and higher detail, providing clearer anatomical information compared to the other SAFIRE Strength variations.
- 11 February 2025
- Published by Poltekkes Kemenkes Surabaya in Journal of Electronics, Electromedical Engineering, and Medical Informatics
- Vol. 7 (2) , 270-282
Open AccessAnalysis of Differences in Image Quality and Anatomical Information of Head CT Scan Examination in Non-Hemorrhagic Stroke Cases Using Sinogram Affirmed Iterative Reconstruction (SAFIRE)
SAFIRE should be utilized to its full potential, as this innovative image reconstruction algorithm can significantly reduce image noise without loss of sharpness, preserving image quality and anatomical information. This is particularly important in the case of non-hemorrhagic stroke, where image noise can obscure small lesions, potentially leading to misdiagnosis and inappropriate treatment. SAFIRE has five variations of strength, making it essential to identify the most optimal SAFIRE Strength for head CT Scan examinations in non-hemorrhagic stroke cases. The aim of this study is to determine differences in image quality and anatomical information in head CT Scan of non-hemorrhagic stroke cases using SAFIRE variations to identify the most optimal SAFIRE Strength. This experimental quantitative study involved a sample of 30 patients, with each case reconstructed using five SAFIRE Strength variations. Image quality was assessed using the IndoQCT application, while anatomical information was evaluated through the visual grading analysis method by three radiologists. Image quality data were analyzed using the Friedman statistical test, which resulted in a p-value of 0.000 (p < 0.05), indicating significant differences among the SAFIRE Strength variations. Similarly, anatomical information data were analyzed using the Kruskal-Wallis statistical test, yielding a p-value of 0.000 (p < 0.05), confirming significant differences across the variations. The results of the study showed that there are significant differences in image quality and anatomical information among the five SAFIRE Strength variations. SAFIRE Strength 3 was identified as the most optimal for head CT Scan examinations in non-hemorrhagic stroke cases, as it produces images with minimal noise and higher detail, providing clearer anatomical information compared to the other SAFIRE Strength variations.
- 12 September 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (10)
Unveiling the influence of ferromagnetic Gd-doped ZnO films on the performance of organic solar cells
Organic solar cells (OSCs) have emerged as a promising technology for renewable energy generation due to their low cost, lightweight, flexibility, and compatibility with roll-to-roll manufacturing. However, OSCs still face challenges in achieving high power conversion efficiency (PCE) due to various factors, including recombination loss. In this study, we investigated the effect of introducing a layer of eight atomic percent gadolinium-doped zinc oxide (Zn0.92Gd0.08O) between the poly(3-hexylthiophene) (P3HT): [6,6]-phenyl butyric acid methyl ester (PCBM) active layer and the fluorine-doped tin oxide (FTO) electrode of the OSC. The reference cell, which has an Au/P3HT:PCBM/ZnO/FTO structure, exhibits a PCE of 0.52%. Remarkably, when the Zn0.92Gd0.08O layer was inserted (Au/P3HT:PCBM/Zn0.92Gd0.08O/FTO), the PCE increased significantly to 3.42%, which is more than six times the increase. Through further analysis, we present that the insertion of the Zn0.92Gd0.08O layer induces spin polarization in the P3HT:PCBM layer, leading to enhanced charge transport and reducing the recombination rate. Based on the findings, it can be concluded that the Zn0.92Gd0.08O film can potentially improve OSC performance.
- 12 September 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 134 (10)
Unveiling the influence of ferromagnetic Gd-doped ZnO films on the performance of organic solar cells
Organic solar cells (OSCs) have emerged as a promising technology for renewable energy generation due to their low cost, lightweight, flexibility, and compatibility with roll-to-roll manufacturing. However, OSCs still face challenges in achieving high power conversion efficiency (PCE) due to various factors, including recombination loss. In this study, we investigated the effect of introducing a layer of eight atomic percent gadolinium-doped zinc oxide (Zn0.92Gd0.08O) between the poly(3-hexylthiophene) (P3HT): [6,6]-phenyl butyric acid methyl ester (PCBM) active layer and the fluorine-doped tin oxide (FTO) electrode of the OSC. The reference cell, which has an Au/P3HT:PCBM/ZnO/FTO structure, exhibits a PCE of 0.52%. Remarkably, when the Zn0.92Gd0.08O layer was inserted (Au/P3HT:PCBM/Zn0.92Gd0.08O/FTO), the PCE increased significantly to 3.42%, which is more than six times the increase. Through further analysis, we present that the insertion of the Zn0.92Gd0.08O layer induces spin polarization in the P3HT:PCBM layer, leading to enhanced charge transport and reducing the recombination rate. Based on the findings, it can be concluded that the Zn0.92Gd0.08O film can potentially improve OSC performance.
- 25 June 2022
- Published by Springer Nature
- p. 59-72
Half Bridge Operational Testing and Optimization for Chemiresistive Escherichia Coli Bacteria Sensor Application
- 25 June 2022
- Published by Springer Nature
- p. 59-72
Half Bridge Operational Testing and Optimization for Chemiresistive Escherichia Coli Bacteria Sensor Application
- Open Access
- 6 February 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (1) , 23-27
Application of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety
Nowadays, health care has turned out to be more technology-oriented. Today's technology is demanded to be practical and easy to use. The number of mobile devices based on the Android operating system has increased significantly based on data. The open-source nature of android helps in programming applications easily according to user requirements. The syringe pump is a medical device that functions to enter the medicinal fluid into the patient's body at a specific dose and time automatically in mL/hour. The syringe pump is generally equipped with an alarm. Alarms have a vital function to provide information to nurses or doctors on duty. Medical officers cannot hear alarms outside the patient monitoring room. This paper aims to design a syringe pump that is equipped with a NodeMCU8266 WiFi module to provide notifications via a smartphone so that nurses or doctors can know the alarm even though they are outside the patient monitoring room. So, this is expected can improve patient safety. In addition, this paper also aims to verify the size of the syringe against the drug flow rate. Based on the test results, the syringe pump can control the drug flow rate with a sensor accuracy of 0.0217 and an error rate of 0.6% at a target volume of 5mL. The syringe pump can also send alarm notifications to smartphones in real-time.
- 6 February 2022
- Published by Poltekkes Kemenkes Surabaya in Indonesian Journal of electronics, electromedical engineering, and medical informatics
- Vol. 4 (1) , 23-27
Open AccessApplication of IoT Using nodeMCU ESP8266 on the Syringe Pump Device to Increase Patient Safety
Nowadays, health care has turned out to be more technology-oriented. Today's technology is demanded to be practical and easy to use. The number of mobile devices based on the Android operating system has increased significantly based on data. The open-source nature of android helps in programming applications easily according to user requirements. The syringe pump is a medical device that functions to enter the medicinal fluid into the patient's body at a specific dose and time automatically in mL/hour. The syringe pump is generally equipped with an alarm. Alarms have a vital function to provide information to nurses or doctors on duty. Medical officers cannot hear alarms outside the patient monitoring room. This paper aims to design a syringe pump that is equipped with a NodeMCU8266 WiFi module to provide notifications via a smartphone so that nurses or doctors can know the alarm even though they are outside the patient monitoring room. So, this is expected can improve patient safety. In addition, this paper also aims to verify the size of the syringe against the drug flow rate. Based on the test results, the syringe pump can control the drug flow rate with a sensor accuracy of 0.0217 and an error rate of 0.6% at a target volume of 5mL. The syringe pump can also send alarm notifications to smartphones in real-time.
- 1 November 2020
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 254
A novel, portable Escherichia coli bacteria sensor using graphene as sensing material
- 1 November 2020
- Published by Elsevier in Materials Chemistry and Physics
- Vol. 254
A novel, portable Escherichia coli bacteria sensor using graphene as sensing material