DCDeyu Cai

Deyu Cai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Deyu Cai has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Delayed inertial control-based coordinated frequency support using wind turbine generators

    by Chenhui Zhang, Xianzhuo Sun, Deyu Cai, Lei Ding, Weiyu Bao, Rui Ma, Vladimir Terzija


  • Open Access

    A Hybrid Forecasting Model for Electricity Demand in Sustainable Power Systems Based on Support Vector Machine

    by Xuejun Li, Minghua Jiang, Deyu Cai, Wenqin Song, Yalu Sun

    Renewable energy sources, such as wind and solar power, are increasingly contributing to electricity systems. Participants in the energy market need to understand the future electricity demand in order to plan their purchasing and selling strategies. To forecast the electricity demand, this study proposes a hybrid forecasting model. The method uses Kalman filtering to eliminate noise from the electricity demand series. After decomposing the electricity demand using an empirical model, a support vector machine optimized by a genetic algorithm is employed for prediction. The performance of the proposed forecasting model was evaluated using actual electricity demand data from the Australian energy market. The simulation results indicate that the proposed model has the best forecasting capability, with a mean absolute percentage error of 0.25%. Accuracy improved by 74% compared to the Support Vector Machine (SVM) electricity demand forecasting model, by 73% when compared to the SVM with empirical mode decomposition, and by 51% when compared to the SVM with Kalman filtering for noise reduction. Additionally, compared to existing forecasting methods, this study’s accuracy surpasses LSTM by 63%, Transformer by 47%, and LSTM-Adaboost by 36%. The simulation of and comparison with existing forecasting methods validate the effectiveness of the proposed hybrid forecasting model, demonstrating its superior predictive capabilities.


  • Research and application of main control system for 2MW direct-driven PMSG-based wind turbine

    by B. Wang, D. Cai, K. Fang, W. Yang, X. Qiu

    A main control system is proposed to achieve safe and stable operation for PMSG-based wind turbines, employing a consistent concept for overall top-level design and sub-module development. A parameter-hierarchical alarm method is presented based on state code. An automatic start-stop strategy is realized with the utilization of state machine. Event snapshots and fault recording using a sliding window are designed. The joint control procedure with the pitch system and converter is illustrated. Considering the nonlinear relationship between pneumatic torque and pitch angle, a pitch dual PI controller with variable gain and variable integration time constants is constructed, utilizing a tower damper, low pass filter, and notch filter. The 3D turbulent wind whose probability distribution conforms to the Weibull distribution is chosen for simulation. Based on Bladed software, a simulation model of the full turbine is established, and calculations of static characteristics, modal analysis, dynamic simulation, and load are done to validate the specified control strategy. The proposed control system is designed based on PLC and applied to a real 2MW wind turbine on a wind farm in Shandong Province. The proposed study is able to provide knowledge for further development and application of similar wind turbines.

  • Open Access

    The Frequency Spectrum Analysis of Wideband Oscillations of Grid-Connected Voltage Source Converter

    by Liyi Wang, Deyu Cai

    With the widespread application of voltage source converters (VSCs) in power systems with high renewable resource penetration, the problem of wideband oscillations caused by interactions between power converters and the power grid has drawn great attention. This paper presents a new methodology for simplifying the mathematical derivations of the impedance model of a VSC. Using the new simplified model, the stability and spectrum characteristics of the performance of the VSC can be clearly analyzed. The proposed second-order d-q impedance model of a grid-connected VSC in the presence of a PLL not only mathematically demonstrates that wideband oscillatory modes always occur in conjugate pairs, but also delivers a clear vision of the physical essence of these wideband oscillations. A classic modal analysis is executed in this paper to demonstrate the stability and frequency spectral characteristics of wideband oscillations in a VSC integrated system. The impact of the control parameters of the VSC on wideband oscillatory stability is thoroughly analyzed by modal analysis using ‘DIgSILENT PowerFactory’ as well as hardware-in-the-loop experiments. This methodology can be considered a powerful tool for the control design of VSCs in the modern power system.


  • Open Access

    The Frequency Spectrum Analysis of Wideband Oscillations of Grid-Connected Voltage Source Converter.

    by Liyi Wang, Deyu Cai

    With the widespread application of Voltage Source Converter (VSC) in the power system with high penetration of renewable resources, the problem of wideband oscillations caused by the interaction between the power converters and the power grid has drawn large attention. This paper presents a new methodology for simplifying the mathematical derivations of the impedance model of VSC. Using the new simplified model, the stability and the spectrum characteristic of the performance of the VSC can be clearly analyzed. The proposed second-order d-q impedance model of the grid connected VSC at presence of PLL, not only mathematically proves that the wideband oscillatory modes always occurs in conjugate pairs, but also deliver a clear vision of the physical essence of the wideband oscillations. The classic modal analysis is executed in the paper to demonstrate the stability and frequency spectral characteristics of the wideband oscillations in the VSC integrated system. The impact of control parameters of the VSC on the wideband oscillatory stability is thouroughly analyzed using the results of the modal analysis. The methodology can be considered a powerful tool for the control design of VSC in the modern power system.

  • Open Access

    Complete operational voltage assessment of Shandong pilot offshore wind project

    by Deyu Cai, Xumin Liu, Dapeng Xu

    This article presents a thorough methodology for the voltage assessment of pilot offshore wind project in Shandong province, China. The results presented in this paper can be considered as the milestone of the offshore wind research in Shandong Province since there is still no grid codes for offshore wind power plant grid connection in the local electrical power grid. It mainly consists of three parts. In the first part, a detailed model of the offshore wind farm created in the DIgSILENT PowerFacotry simulation platform is presented, including wind turbines, power converters, transformers, submarine cables and relevant control schemes. In the second part, nonlinear time‐domain simulations were performed to analyze the wind farm's active power, reactive power, and voltage conditions under different wind scenarios. Based on the simulations results, a dynamic reactive power compensation system was proposed, and the consequence of the reactive power compensation was also demonstrated using nonlinear time‐domain simulations.


  • Open Access

    Identification of control parameters of the permanent magnetic synchronous generator using least square method

    by Hongxu Yin, Yanfei Wei, Yingjie Zhang, Panpan Jing, Deyu Cai, Xumin Liu


  • Open Access

    Complete Operational Voltage Assessment of Shandong Pilot Offshore Wind Project

    by Deyu Cai, Xumin Liu, Dapeng Xu

    This paper presents a thorough methodology for the voltage assessment of pilot offshore wind project in Shandong province, China. The results presented in this paper can be considered as the milestone of the offshore wind research in Shandong since there is still no grid codes for offshore wind power plant grid connection in the local electrical power grid. It mainly consists of three parts. In the first part, a detailed model of the offshore wind farm created in the DIgSILENT PowerFacotry simulation platform is presented, including wind turbines, power converters, transformers, submarine cables and relevant control schemes. In the second part, nonlinear time-domain simulations were performed to analyse the wind farm’s active power, reactive power, and voltage conditions under different wind scenarios. Based on the simulations results, a dynamic reactive power compensation system was proposed, and the consequence of the reactive power compensation was also demonstrated using nonlinear time-domain simulations.