GSGenta Sahara

Genta Sahara

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Genta Sahara has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • METHODS FOR INVESTIGATING CONTRACTION CHARACTERISTICS OF A PART OF MUSCLES FOR IMPLANTABLE POWER GENERATION SYSTEMS

    by Genta Sahara, Wataru Hijikata, Yusuke Inoue, Akihiro Yamada, Yasuyuki Shiraishi, Aoi Fukaya, Masato Karube, Tatsuya Genda, Naoki Iwamoto, Yuma Tachizaki, et al.

    To develop a power generation system as a solution to the power supply problems of small active implantable medical devices, we proposed a new method to examine muscles using skeletal muscle contraction through electrical stimulation. Realization of the system requires data on the contraction characteristics of a part of the muscles through which blood flows; thus, a dedicated setup was built and verified using a goat. The connecting parts were attached to two points in the large muscle of the goat’s trunk; one was fixed and the other slid along the guide. The distance and force between the two points, approaching each other, were measured by contracting the muscle between the points using electrical stimulation and pulling the measurement cart. The contraction distance and force were measured simultaneously, and the dynamic work of the contraction was calculated. The muscle work occurred with almost the same time delay regardless of the load, and the work tended to be greater when the contraction force, and not the contraction distance, of the muscle was large. The setup is physiological, simple, and versatile. Our setup can potentially be used in the development of implantable power generation systems and in other related fields.

  • Open Access

    Design of an Artificial Tongue Driven by Shape Memory Alloy Fibers

    by Yasuyuki Shiraishi, Akihiro Yamada, Genta Sahara, Tomoyuki Yambe, Kengo Kato, Jun Ohta, Yukio Katori, Dai Homma

    Dysphasia is one of the complications which may cause functional disability after the surgical treatment of oral cancer. The loss of the function derived by tongue and other oral tissues impairs the retention and delivery of liquids and food masses as well as the swallowing motion into pharynx. As accumulation of liquids or food masses in the larynx can lead to pneumonia, therefore swallowing support to improve each coordination of the tongue, the epiglottis and the esophagus in the process of swallowing is highly desirable. In this study, we designed a new artificial tongue which was capable of contracting to deliver the bolus masses in the swallowing propulsion phase in the oral cavity. We designed a two-layered artificial tongue simulating the anatomical identical muscle structures with the longitudinal muscle, and the transverse muscle-genioglossus layer. A silicone rubber material was used for the surface layer, and the covalent shape memory alloy fibers (diameter: 150µm) were implemented in the secondary structure beneath of the silicone rubber material of the artificial tongue. Its contraction was driven by with shape memory alloy fibers shortage inside of the artificial tongue unit. The actuation was accurately controlled by the originally designed electrical current input with pulse width modulation. Firstly, we examined a prototype structure of the artificial tongue as well as the changes in unit thickness as it constricted by electric power supply switching. Secondly, we performed a feasibility study of the prototype into the head-neck medical training model with larynx-tracheal structure with esophagus. The results were as follows: a) the artificial tongue model showed a large contraction with a motion to increase upward pressure, b) the tongue unit expressed the capability of reducing shallow space between dorsal tongue surface and palate in the oral cavity model. Therefore, the first artificial tongue design with active contractile motion will be useful orally installable device for improving delivery function of bolus masses through swallowing procedure in dysphasia.Clinical Relevance— The active artificial tongue system designed for the first time exhibited an effective contractile motion to support bolus food masses propulsion in swallowing process in the oral cavity in the patients with dysphasia

  • Open Access

    Development of muscle connection components for implantable power generation system

    by Genta Sahara, Akihiro Yamada, Yusuke Inoue, Yasuyuki Shiraishi, Wataru Hijikata, Aoi Fukaya, Tomoyuki Yambe

    We have been developing an implantable power generation system that uses muscle contraction following electrical stimulation as a permanent power source for small implantable medical devices. However, if the muscle tissue is overloaded for power generation, the tissue may rupture or blood flow may be impaired. In this study, we developed a new muscle-connecting component that solves these problems. The new connection device has three rods attached to the muscle fibers, and the force exerted on the muscle fibers is converted from horizontal to vertical when the muscle contracts. We conducted simulations with a three-dimensional (3D) model, as well as pulse wave muscle measurements and in vivo tests using the actual muscle. The pulse wave in the connecting part and its downstream were optically measured from the muscle surface, and the blood flow was not obstructed. The 3D model simulations revealed that the distribution of stress was preferable compared with the case in which a rod was stuck vertically in the muscle. In the in vivo muscle tests, the metal rod and resin parts were attached to the muscle, and a load of up to approximately 9 N was applied to the connecting part. Consequently, the connecting part was stable and integrated with the muscle, and there was no damage in the muscle. Although no long-term or histological evaluations were conducted, the device may be useful because of the intramuscular power generation owing to the minimal load applied on the part connected with the muscle.