Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mariya Dimitrova has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of Thermal Processing on Surface Roughness of Injection-Molded Denture Base Polymers

    by Bozhana Chuchulska, Mariya Dimitrova, Boyan Dochev, Kliment Georgiev

    Surface roughness and mechanical performance are critical determinants of the clinical behavior, hygiene, and longevity of denture base materials. This study investigated the influence of two extrusion temperatures—280 °C and 300 °C—on both the surface roughness and compressive strength of ThermoSens thermoplastic polymer specimens over a 7-day immersion period. Surface roughness was evaluated at baseline, 24 h, and 7 days using a contact profilometer, while compressive strength was measured after 7 days following ISO 604 guidelines. Samples processed at 300 °C exhibited a significantly greater reduction in surface roughness over time (28.3%) compared with those processed at 280 °C (18.3%). However, although specimens processed at 300 °C showed a greater percentage reduction, their absolute roughness values remained higher than those processed at 280 °C. Compression testing demonstrated higher strength and modulus values in the 300 °C group (91.6 ± 1.8 MPa; 1887.9 ± 42.3 MPa) compared to the 280 °C group (82.3 ± 2.1 MPa; 1755.4 ± 38.7 MPa). These findings indicate a trade-off between improved mechanical performance at higher processing temperatures and lower surface roughness at lower temperatures, highlighting the need for the careful optimization of processing conditions.

  • Open Access

    Mapping the Associations Between Body Mass Index and Key Psychosocial Determinants: Resilience, Perceived Stress, and Emotion Regulation in Young Adults—A Cross-Sectional Study

    by Boris Tilov, Pavel Stanchev, Mariya Dimitrova, Meri Hristamyan, Desislava Makakova-Tilova

    Background: Obesity and overweight are escalating global public health concerns. This study examined the relationship between Body Mass Index (BMI) and psychological factors in young adults. Methods: A total of 283 participants aged 19–30 years were categorized by BMI (normal weight, overweight, obesity) using self-reported data. Psychological assessments included the Connor–Davidson Resilience Scale (CD-RISC), Perceived Stress Scale (PSS), Emotion Regulation Questionnaire (ERQ), and Buss–Perry Aggression Questionnaire (BPAQ), all with acceptable reliability. Individuals with psychiatric, neurological, or chronic somatic conditions were excluded. Analyses involved MANOVA, ANOVA, ANCOVA, and hierarchical regression, controlling for gender, physical activity, smoking, caffeine, alcohol, medication, and sleep disturbances. Results: MANOVA showed a near-significant multivariate effect of BMI on psychological variables (Wilks’ Lambda = 0.913, p = 0.068). ANOVA revealed significant differences in perceived stress among BMI groups (F (2, 279) = 3.796, p = 0.024), with obese participants reporting lower stress. Hierarchical regression identified perceived stress as the strongest predictor of BMI, followed by resilience and physical aggression. General aggression was negatively associated with BMI, suggesting potential compensatory mechanisms. Conclusions: Perceived stress and resilience showed small but significant associations with BMI in young adults, suggesting a modest contribution of psychological factors to weight-related health.


  • Open Access

    The Role of Digital Innovations in Shaping Contemporary Fixed Prosthodontics: A Narrative Review

    by Mariya Dimitrova

    The rapid digitization of dentistry is significantly transforming fixed prosthodontics, a discipline highly dependent on technical precision. This narrative review, incorporating a structured literature search, provides a critical overview of how digital tools—including computer-aided design and manufacturing (CAD/CAM), intraoral scanners (IOS), and additive manufacturing—are influencing clinical protocols and production methods. A database-guided selection process was employed to identify relevant studies published between 2000 and 2024, spanning in vitro research, observational studies, and clinical trials. While digital workflows offer promising benefits, such as increased accuracy, efficiency, and patient comfort, supporting evidence remains preclinical or short-term in nature. The review highlights areas of innovation as well as ongoing limitations in clinical validation, standardization, and adoption. A more cautious interpretation of the current evidence is warranted, especially regarding long-term clinical outcomes and cost-effectiveness. This review aims to inform clinicians, researchers, and educators about both the potential and the present limitations of digital fixed prosthodontics.


  • Open Access

    Exploring Polymeric Surfaces Manufactured Under Different Temperature Conditions—A Preliminary Experimental Study of Hardness

    by Bozhana Chuchulska, Mariya Dimitrova, Boyan Dochev, Kliment Georgiev

    Polymers are essential materials in the fabrication of partial and complete dentures, where their mechanical properties directly impact durability, comfort, and clinical performance. This study examines the influence of different manufacturing temperatures on the surface hardness of polymeric materials used in dental applications. A total of 60 experimental samples with a rectangular shape of Vertex ThermoSens polymer (Vertex Dental, 3D Systems, Soesterberg, The Netherlands) were fabricated through injection molding at 280 °C and 300 °C and analyzed over time to assess changes in their properties. Hardness measurements, conducted using the EQUOTIP Shore D hardness tester (Proceq SA, Schwerzenbach, Canton of Zürich, Switzerland), indicated increased hardness over time, with higher values observed in samples fabricated at 300 °C. A two-way ANOVA was performed to evaluate the statistical significance of temperature and time on hardness, revealing a significant effect (F = 14.73, p = 0.0185). These findings suggest that processing polymers at elevated temperatures improves surface hardness, significant for denture longevity and patient comfort. Increased hardness contributes to greater wear resistance. Optimizing polymer manufacturing conditions can thus lead to improved clinical outcomes, ensuring more durable and biocompatible dental prostheses.


  • 3D Printing Revolutionizing Rural Dental Care

    by Mariya Dimitrova

    3D printing, or additive manufacturing, is transforming dentistry by enabling precise, affordable, and localized production of dental devices. Using a layer-by-layer process with materials like resins and metals, it creates prosthetics, orthodontic devices, and surgical guides, improving workflows and patient care. In rural areas, where economic and infrastructure barriers limit access to specialized dental care, 3D printing offers a revolutionary solution. By enabling on-site production of custom devices, it reduces costs, shortens treatment times, and bridges the gap between rural and urban healthcare. Successful cases in India, Sub-Saharan Africa, and Southeast Asia highlight its potential to empower local providers and improve accessibility. However, challenges like high startup costs, limited materials, and training requirements hinder broader adoption. Future advancements, including AI integration and improved materials, could overcome these barriers.3D printing promises equitable, high-quality dental care by decentralizing production and improving access.


  • Open Access

    Adjunctive Effects of Diode Laser in Surgical Periodontal Therapy: A Narrative Review of the Literature

    by Giuseppe D’albis, Marta Forte, Maria Chiara Fioriello, Alexandra Artin, Anna Montaruli, Adriano Di Grigoli, Rada Kazakova, Mariya Dimitrova, Saverio Capodiferro

    The surgical procedures in the treatment of periodontitis generally aim to reduce pocket depth, improve teeth maintenance, and enhance long-term stability. Several approaches have been proposed over the years including different techniques, drugs, and medical devices, with the main purpose to minimalize the surgical procedure and improve both the outcomes and patient compliance. Among all the medical devices proposed in surgical and non-surgical periodontology, different laser wavelengths (e.g., Erbium: YAG, Erbium: CR, KTP, Diode) have been studied worldwide but generally with inconsistent results. Nowadays, the diode laser is one of the most used lasers among general dentists, also promoted as an adjunctive therapy in periodontology, mainly in non-surgical procedures. This study aims to review data emerging from the literature on the use of diode lasers and adjunctive therapy to the conventional periodontal surgery. This research was conducted using PubMed and Scopus search engines with a combination of relevant keywords, including “Surgical Periodontal Therapy”, “Periodontal Surgery”, “Periodontal Regenerative Surgery”, and “Surgical Treatment for Periodontal Disease” in combination with “Diode Laser”, “Diode-Driven Laser”, and “Diode Emission Laser”. Selected articles were carefully reviewed to identify studies reporting data on the effectiveness of diode lasers in periodontal surgery. Results of the current review suggest potential clinical benefits of diode laser-assisted periodontal surgery, as studies reported improvements in key parameters such as clinical attachment level (CAL), bleeding on probing (BOP), and plaque index (PI) postoperatively. Additionally, VAS scores, indicative of post-surgical discomfort, were lower for laser-treated sites, and a short-term reduction in periodontal pathogens was observed. However, the clinical outcomes significantly differ across the studies, and the evidence does not uniformly support a superior effectiveness of diode lasers as an adjunctive tool in surgical periodontology. While the data indicate that diode laser use may contribute to enhanced periodontal health and possibly accelerate healing in some cases, these findings should be interpreted cautiously, as further research, possibly multicentric and in large numbers but mandatory with well-defined protocols (stage of periodontitis, preliminary non-surgical procedures and results, laser wavelength and protocol of use, post-operative maintenance, follow-up clinical and radiological criteria) are surely needed to possibly validate the observations emerging from the current review and eventually to standardize clinical protocols in the future. Such limitations have been well addressed in this paper and are clearly discussed and essentially related to the focus on the total uncertainty of the literature and general caution.


  • Understanding Customers' Intentions to Use Digital Dental Health Services

    by Kamel Mouloudj, Ahmed Chemseddine Bouarar, Dachel A. Martínez Asanza, Mariya Dimitrova

    This study extends the technology acceptance model (TAM) by integrating additional variables—attitudes and social media influence—to explore the factors affecting customers' intentions to use digital dental health services in Algeria. Utilizing a convenience sampling method, the research gathered 136 valid responses through a structured questionnaire. The analysis revealed that customers' intentions are significantly influenced by four key factors: perceived ease of use, perceived usefulness, attitudes, and social media. These findings underscore the importance of not only technological perceptions but also social and psychological elements in promoting the adoption of digital dental care. The study contributes to a deeper understanding of customer behavior in the context of digital health services, offering valuable insights for practitioners and policymakers aiming to enhance the acceptance of such innovations.


  • Open Access

    Exploring the Differential Diagnosis of Adrenal Adenoma in the Context of Situs Ambiguous: A Clinical Case Study

    by Pavel E. Stanchev, Mariya Dimitrova, Desislava Makakova, Boris Tilov

    Situs anomalies, including situs inversus and situs ambiguous (SAMB), are rare congenital conditions typically noted in pediatric populations, with SAMB being particularly uncommon in adults. This case study addresses the incidental discovery of situs ambiguous with polysplenia in a 65-year-old man evaluated for suspected adrenal adenoma. The patient’s medical history included benign prostatic hyperplasia and tuberculous pleurisy. Methods included a thorough physical examination and laboratory tests, which showed normal cortisol levels and ACTH rhythm. Contrast-enhanced CT imaging revealed multiple spleens near the right adrenal region, altered liver positioning, a truncated pancreas, and a right-sided stomach, while the right adrenal gland was not visualized. Notably, the patient exhibited minimal symptoms despite these significant anatomical anomalies. The findings underscore the rarity of situs ambiguous in adults and its unexpected association with endocrine pathology. This case highlights the importance of comprehensive imaging and a multidisciplinary approach in managing patients with unusual anatomical presentations. It suggests that situs anomalies may be more prevalent in adult populations than previously recognized and emphasizes the need for increased clinical awareness and evaluation in similar cases.

  • Open Access

    Comparative Study of the Fracture Resistance of 3D-Printed and Prefabricated Artificial Teeth for Removable Dentures

    by Mariya Dimitrova, Rada Kazakova, Angelina Vlahova

    The integration of three-dimensional (3D) printed resin denture teeth represents a significant advancement in digital dentistry. This study aims to assess the ability of 3D-printed denture teeth to withstand chipping and indirect tensile fractures, comparing them with conventionally manufactured resin denture teeth. Four groups, each comprising 30 specimens, were examined: Group 1 featured 3D-printed denture teeth (NextDent, 3D Systems, Soesterberg, The Netherlands), while the others included commercially obtained Ivostar Shade, SpofaDent Plus, and Major Super Lux teeth. Stereolithography 3D printing was utilized to produce methacrylate-based photopolymerized resin teeth models for Group 1, while the remaining groups were commercially sourced. Chipping and indirect tensile fracture tests were performed at a rate of 0.8 mm/min until material failure, offering valuable insights into the mechanical properties of the tested denture teeth. Statistical analysis was carried out using one-way analysis of variance (ANOVA), coupled with Tukey’s honestly significant difference test to compare multiple groups, with a significance threshold of p < 0.05. The findings showed that 3D-printed resin denture teeth exhibited greater indirect tensile fracture resistance than Major Super Lux and Ivostar Shade, though they were surpassed by SpofaDent Plus. In the chipping test, the 3D-printed teeth experienced buccal chipping without distortion, indicating their structural stability under localized force. Fractures during the indirect tensile test originated near the loading point and extended cervically along the inner slopes of both cusps, displaying consistent fracture patterns. These results demonstrate that 3D-printed denture teeth made from resin materials provide adequate fracture resistance for clinical use, although further refinement of materials could enhance their performance relative to conventional alternatives.


  • Open Access

    Bilateral Symmetry in the Aesthetic Area Achieved by Digital Smile Design on 3D Virtual Patient and Conventional Diagnostic Wax-Up—A Comparative Study

    by Maria Hristozova, Mariya Dimitrova, Stefan Zlatev

    Background: Digital diagnostic waxing is a contemporary alternative to the conventional wax-up method. This study aims to evaluate the impact of both techniques on the perceived frontal symmetry in aesthetic treatment planning. Dental symmetry significantly influences smile perception and, consequently, the acceptance of treatment outcomes, highlighting its clinical importance in restorative dentistry. Materials and Methods: A total of 100 teeth were measured, with 50 (n = 50) waxed up using traditional modeling techniques and 50 using a face-guided digital approach. The study involved ten patients requiring fixed restorations in the aesthetic zone. Both digital and conventional wax-ups were performed for each participant. Gypsum models with wax-ups were digitized and superimposed onto the digital diagnostic design using 3Shape Dental Designer Studio software, Version 2023 (3Shape, Copenhagen, Denmark). Screenshots of the frontal view were captured, and the width of each morphologically altered tooth was measured using ImageJ software Version 1.54 (National Institutes of Health, Bethesda, MD, USA). Results: The results indicated no statistically significant difference in symmetry between the right and left sides achieved by the two diagnostic approaches (t-value = −1.89, p-value = 0.07). The perceived symmetry of morphologically modified frontal teeth, as achieved by digital and conventional waxing, was found to be comparable. Conclusions: Digital diagnostic planning is validated as a reliable alternative to the conventional wax-up method, offering comparable accuracy in achieving dental symmetry while potentially enhancing efficiency and precision in the aesthetic treatment planning process. This result underscores the potential of digital technologies to streamline clinical workflows and improve patient outcomes. Clinically, achieving symmetry in the aesthetic zone is crucial for patient satisfaction and acceptance of restorative procedures, emphasizing the need for continued integration of digital tools in dental practice.