Sungsoo Lim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sungsoo Lim has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jeong-Yun Sun
Seoul National University
4 shared publications - Min-Gyu Lee
Department of Materials Science and Engineering, Seoul National University, Seoul 08826, South Korea
3 shared publications - Jae-Man Park
Department of Chemical and Environmental Engineering, Yale University, New Haven, CT 06520, United States
2 shared publications - Younghoon Lee
Department of Mechanical Engineering Kyung Hee University Yongin Republic of Korea
2 shared publications - Yun Hyeok Lee
Departmant of Materials Science and Engineering Seoul National University Seoul 08826 Republic of Korea
2 shared publications - Byung Ik Park
Department of Materials Science and Engineering Seoul National University Seoul Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 12 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (37) , eadw6611
Dynamically assembled magnetic nanoparticles in a phase transitional matrix for reconfigurable electronics
The structure of an electronic device is predetermined at its birth, necessitating new designs and fabrication processes for alternative functions. The advent of reconfigurable electronics, modifying its circuits after manufacture, has unlocked the potential for devices to perform adaptive roles as needed. However, the trade-off between the degree of freedom to reform its structure and electrical stability restricts its potential roles, diminishing the system’s significance. Here, we present a reconfigurable assembly of magnetic nanoparticles in a phase transitional matrix (RAMP) system capable of seamlessly transforming their structure with robust electrical junctions. Nanoparticles form conductive percolation under a precisely patterned magnetic field. Within a phase transitional matrix, junctions between nanoparticles are tightened, enhancing electrical performance during transitions. We demonstrated in situ electrical switching and high-resolution alternating current electroluminescence display using the RAMP system. With enhanced reconfigurability and electrical reliability, we anticipate that the RAMP system will suggest a previously unexplored approach to on-demand electronics.
- 12 September 2025
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 11 (37) , eadw6611
Open AccessDynamically assembled magnetic nanoparticles in a phase transitional matrix for reconfigurable electronics
The structure of an electronic device is predetermined at its birth, necessitating new designs and fabrication processes for alternative functions. The advent of reconfigurable electronics, modifying its circuits after manufacture, has unlocked the potential for devices to perform adaptive roles as needed. However, the trade-off between the degree of freedom to reform its structure and electrical stability restricts its potential roles, diminishing the system’s significance. Here, we present a reconfigurable assembly of magnetic nanoparticles in a phase transitional matrix (RAMP) system capable of seamlessly transforming their structure with robust electrical junctions. Nanoparticles form conductive percolation under a precisely patterned magnetic field. Within a phase transitional matrix, junctions between nanoparticles are tightened, enhancing electrical performance during transitions. We demonstrated in situ electrical switching and high-resolution alternating current electroluminescence display using the RAMP system. With enhanced reconfigurability and electrical reliability, we anticipate that the RAMP system will suggest a previously unexplored approach to on-demand electronics.
- Open Access
- 22 August 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (9)
Enzyme‐Regulated Extended Swelling of Hydrogels for Dehiscence‐Less Tissue Expansions
Tissue expansion is traditionally achieved by injecting saline into an implanted silicone balloon via external tubing, which causes patient discomfort. Hydrogels eliminate the need for tubing due to their self‐swelling properties, but they fail to prevent suture wound dehiscence due to immediate swelling after implantation. Here, the concept of “extended swelling” in an interpenetrating hydrogel network is introduced to avoid dehiscence. The hydrogel consists of enzymatically degradable hyaluronic acid (HA) networks and non‐degradable polyacrylic acid (PAAc) networks. The gel remains structurally intact until suture wound healing after implantation by the constraint of the HA networks on the PAAc networks. Upon hyaluronidase (HYAL) injection, the HA networks degrade, initiating the extended swelling after which enzymatic degradation controls its onset and rate. Furthermore, the generalized ideal elastomeric gel model is employed to understand the extended swelling process. The model predicts the maximum extended equilibrium swelling ratio in vivo, confirming the hydrogel's ability to generate sufficient pressure while preventing overexpansion beyond the tissue rupture threshold. The theoretical framework aligns with experimental observations, demonstrating that the tissue expansion is induced by yes1‐associated protein (YAP1)‐mediated epidermal proliferation. This approach establishes its potential as a next‐generation tissue expander for clinical applications.
- 22 August 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 36 (9)
Open AccessEnzyme‐Regulated Extended Swelling of Hydrogels for Dehiscence‐Less Tissue Expansions
Tissue expansion is traditionally achieved by injecting saline into an implanted silicone balloon via external tubing, which causes patient discomfort. Hydrogels eliminate the need for tubing due to their self‐swelling properties, but they fail to prevent suture wound dehiscence due to immediate swelling after implantation. Here, the concept of “extended swelling” in an interpenetrating hydrogel network is introduced to avoid dehiscence. The hydrogel consists of enzymatically degradable hyaluronic acid (HA) networks and non‐degradable polyacrylic acid (PAAc) networks. The gel remains structurally intact until suture wound healing after implantation by the constraint of the HA networks on the PAAc networks. Upon hyaluronidase (HYAL) injection, the HA networks degrade, initiating the extended swelling after which enzymatic degradation controls its onset and rate. Furthermore, the generalized ideal elastomeric gel model is employed to understand the extended swelling process. The model predicts the maximum extended equilibrium swelling ratio in vivo, confirming the hydrogel's ability to generate sufficient pressure while preventing overexpansion beyond the tissue rupture threshold. The theoretical framework aligns with experimental observations, demonstrating that the tissue expansion is induced by yes1‐associated protein (YAP1)‐mediated epidermal proliferation. This approach establishes its potential as a next‐generation tissue expander for clinical applications.
- 24 August 2022
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 18 (35) , 6487-6510
Materials development in stretchable iontronics
By classifying stretchable ionic materials into three types of components (ionic conductors, ionic semiconductors, and ionic insulators), we summarized materials development in stretchable iontronics in terms of molecular interactions.
- 24 August 2022
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 18 (35) , 6487-6510
Materials development in stretchable iontronics
By classifying stretchable ionic materials into three types of components (ionic conductors, ionic semiconductors, and ionic insulators), we summarized materials development in stretchable iontronics in terms of molecular interactions.
- 31 March 2022
- Published by Wiley in Advanced Materials
- Vol. 34 (19) , e2108586
Triboresistive Touch Sensing: Grid‐Free Touch‐Point Recognition Based on Monolayered Ionic Power Generators
Recent growing pursuit of skin‐mountable devices has been impeded by the complicated structures of most sensing systems, containing electrode grids, stacked multilayers, and even external power sources. Here, a type of touch sensing, termed “triboresistive touch sensing”, is introduced for gridless touch recognition based on monolayered ionic power generators. A homogeneous monolayer, i.e., ionic poly(dimethylsiloxane) (PDMS), generates electricity based on the electric field generated by touch. Voltages generated at each corner of the ionic PDMS rely on resistance between touch points and each corner, ensuring recognition of the touch positions without the need for electrode grid layers and external power sources. With notable advantages of high transparency (96.5%), stretchability (539.1%), and resilience (99.0%) of the ionic PDMS, epidermal triboresistive sensing is demonstrated to express touch position and readily play a musical instrument. A gridless system of triboresistive sensing allows rearrangement of the touch sections according to a given situation without any physical modification, and thus easily completes consecutive missions of controlling position, orientation, and gripping functions of a robot.
- 31 March 2022
- Published by Wiley in Advanced Materials
- Vol. 34 (19) , e2108586
Triboresistive Touch Sensing: Grid‐Free Touch‐Point Recognition Based on Monolayered Ionic Power Generators
Recent growing pursuit of skin‐mountable devices has been impeded by the complicated structures of most sensing systems, containing electrode grids, stacked multilayers, and even external power sources. Here, a type of touch sensing, termed “triboresistive touch sensing”, is introduced for gridless touch recognition based on monolayered ionic power generators. A homogeneous monolayer, i.e., ionic poly(dimethylsiloxane) (PDMS), generates electricity based on the electric field generated by touch. Voltages generated at each corner of the ionic PDMS rely on resistance between touch points and each corner, ensuring recognition of the touch positions without the need for electrode grid layers and external power sources. With notable advantages of high transparency (96.5%), stretchability (539.1%), and resilience (99.0%) of the ionic PDMS, epidermal triboresistive sensing is demonstrated to express touch position and readily play a musical instrument. A gridless system of triboresistive sensing allows rearrangement of the touch sections according to a given situation without any physical modification, and thus easily completes consecutive missions of controlling position, orientation, and gripping functions of a robot.