AMAnna P. Mikhailova

Anna P. Mikhailova

*This is an algorithmically generated author record based on publicly available information.

Anna P. Mikhailova has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Results of bone grafting using a xenogenic cortical plate BiOTECK

    by Tаtyana V. Brailovskaya, Zoimbek M. Abaev, Anna P. Mikhailova, Khalil I. Mamedov, Anna P. Vedyaeva, Брайловская Татьяна Владиславовна, Мамедов Халил Илгам Оглы

    BACKGROUND: The fundamental condition that determines the effectiveness of treatment, with immediate and long-term positive results, is the amount of bone tissue in the jaws at the proposed implantation site. Defects in the dentition to a large extent and severe atrophy of the bone tissue of the jaws due to the loss of teeth significantly limit the use of dental implantation. It is reasonable to expand the indications for the use of dental implants in cases of atrophy of the jaw bone tissue in the installation site. This allows the optimization of surgical techniques aimed at increasing the volume of the jaw bone tissue, such as the use of new osteoplastic materials for guided bone regeneration. AIM: This study aimed to analyze the results of a jawbone graft using a BiOTECK xenogeneic cortical plate. MATERIALS AND METHODS: The test group consisted of 22 patients (11 men and 11 women) with jawbone atrophy. All patients underwent bone graft surgery using a BiOTECK xenogeneic cortical plate (BiOTECK, Italy). In the course of the study, all patients with jawbone loss underwent a dynamic clinical and X-ray examination during the following stages: during the dental implant surgery planning stage aimed at determining the volume of the bone tissue available and identifying the associated conditions and diseases (prior to conducting an osteoplastic procedure), prior to dental implant installation (6 months after osteoplastic surgery), and prior to the start of the orthopedic stage of treatment (12 months after osteoplastic surgery). RESULTS: The cone beam computed tomography data were analyzed and statistically processed to obtain the results. It was revealed that the values of the “bone densitometry” indicator increased 6 months after the bone graft using the BiOTECK xenogeneic cortical plate, and the values of the “densitometric density of jaw bone tissue” indicator increased. Immediately after bone grafting using the BiOTECK xenogeneic cortical plate, the thickness of the bone tissue of the upper jaw increased by an average of 5.0±0.1 mm and that of the lower jaw increased by an average of 3.9±0.1 mm. In the first stage of the dental implant surgery (6 months after osteoplastic procedure), due to resorption, the thickness of the bone tissue of the alveolar process of the upper jaw decreased by 1.1±0.1 mm and amounted to 6.8±0.1 mm (bone resorption rate: 13.9%), and the thickness of the bone tissue of the alveolar process of the lower jaw decreased by 0.8±0.2 mm and amounted to 6.6±0.3 mm (bone resorption rate: 10.3%). CONCLUSION: The clinical and X-ray results obtained 1 year after installing dental implants and performing bone graft surgery using the BiOTECK xenogeneic cortical plate indicate a stable volume of marginal bone tissue in the area of alveolar crest reconstruction.


  • Vascularized autograft remodeling after reconstructive surgery in patients with jaw defects and deformities

    by T.V. Brailovskaya, E.V. Verbo, A.M. Deniev, A.G. Nadtochiy, S.V. Abramyan, A.P. Mikhailova, R.V. Kalinin

    На основании данных компьютерной томографии проведена оценка результативности ремоделирования реваскуляризированных аутотрансплантатов у пациентов с дефектами и деформацией челюстей после проведения им операций по реконструкции и восстановлению челюстей с последующей дентальной имплантацией. ЦЕЛЬ ИССЛЕДОВАНИЯ Наблюдение за изменениями структуры и размеров аутотрансплантатов после проведенных операций по реконструкции и восстановлению челюстей с использованием реваскуляризированных аутотрансплантатов. МАТЕРИАЛ И МЕТОДЫ В исследование были включены 30 пациентов с дефектами челюстей (возраст 17—65 лет), проходивших лечение в ФГБУ «НМИЦ "ЦНИИСиЧЛХ"» Минздрава России за период с 2016 по 2020 г. В 1-ю группу вошли 23 человека, данным пациентам операции по реконструкции и восстановлению челюсти проводились с целью удаления доброкачественных новообразований и после травм; во 2-ю группу вошли 7 человек, этим пациентам были проведены операции по восстановлению и реконструкции челюсти с целью удаления злокачественных новообразований с последующей лучевой терапией. Через 6 мес после выполнения данных операций и через 6 мес после проведения дентальной имплантации всем пациентам была проведена мультиспиральная компьютерная томография. Для того чтобы оценить плотность и размеры реваскуляризированного аутотрансплантата малоберцовой кости, было определено отношение толщины двух кортикальных слоев к толщине кости, то есть определен кортикальный индекс (КИ). Вычисление КИ проведено в вертикальной (КИ-В) и трансверзальной (КИ-Т) плоскостях. Для анализа функционального состояния реваскуляризированного аутотрансплантата использован индекс ремоделирования (ИР), который представляет собой отношение двух величин: поперечного измерения реваскуляризированного аутотрансплантата в настоящем исследовании к такому же измерению в предыдущем (исходном) исследовании. ИР вычисляли как в вертикальной (ИР-В), так и в трансверзальной (ИР-Т) плоскостях. ЗАКЛЮЧЕНИЕ Результаты исследования позволяют сделать вывод, что на сроках через 6 мес после реконструктивного оперативного вмешательства и через 6 мес после последующей установки дентальных имплантатов динамика ремоделирования аутотрансплантата достоверно ниже (p≤0,05) у тех пациентов, которые перенесли лучевую терапию, по сравнению с пациентами, которым лучевая терапия не выполнялась.