Tat'Yana Vladislavovna Brailovskaya
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tat'Yana Vladislavovna Brailovskaya has a total of 97 co-authors. Here are the top co-authors by number of shared publications:
- Fedor F. Losev
Central research Institute of dentistry and maxillofacial surgery Ministry of health of Russia
15 shared publications - A.F. Sharganov
National Medical Research Center for Dentistry and Maxillofacial Surgery of the Ministry of Health of Russia
7 shared publications - Zoimbek M. Abaev
I.M. Sechenov First Moscow State Medical University (Sechenov University)
5 shared publications - A. A. Kulakov
Central Scientific Research Institute of Dentistry and Maxillofacial Surgery Ministry of Health of Russia
4 shared publications - Fedor S. Rusanov
Central Research Institute of Dentistry and Maxillofacial Surgery
4 shared publications - Irina Ya. Poyurovskaya
Central Research Institute of Dentistry and Maxillofacial Surgery
4 shared publications
Latest Publications
- 23 October 2026
- Published by Joint Editorial Office of the Ministry of Internal Affairs of Russia in Medical Bulletin of the Ministry of Internal Affairs
- Vol. 2026 (5) , 5-9
Effect of the composition of osteoplastic material on formation of bone regenerate and stability of dental implants with open sinus elevation
This clinical study evaluates the effect of various combinations of autologous and xenogenic bone tissues on bone regeneration and stability of dental implants after open sinus elevation.
- 23 October 2026
- Published by Joint Editorial Office of the Ministry of Internal Affairs of Russia in Medical Bulletin of the Ministry of Internal Affairs
- Vol. 2026 (5) , 5-9
Effect of the composition of osteoplastic material on formation of bone regenerate and stability of dental implants with open sinus elevation
This clinical study evaluates the effect of various combinations of autologous and xenogenic bone tissues on bone regeneration and stability of dental implants after open sinus elevation.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 19-25
The effect of autoclaving conditions on the microstructure of the Dental Yellow Clear PRO photopolymer material produced by stereolithography
Objective. A comparative study of the effect of two clinically acceptable steam sterilization modes on the microstructure of samples made of the domestic photopolymer material Dental Yellow Clear PRO using stereolithography with different layer heights. Material and Methods. Disc-shaped specimens were printed with layer height of 0.05 mm and 0.1 mm and subsequently sterilized using two autoclaving protocols: a “Soft Program” (121°C, 1.1 bar, 15 min) and a “Flash Program S” (134°C, 2.2 bar, 3.5 min). Surface morphology and interlayer integrity were analyzed using field-emission scanning electron microscopy (FE-SEM). Results. Autoclaving did not lead to interlayer delamination or macroscopic structural defects, regardless of layer thickness. Sterilization at 121°C resulted in partial smoothing of interlayer boundaries without signs of substantial material degradation. In contrast, sterilization at 134°C produced more pronounced alterations, including localized surface softening and the formation of microstructural heterogeneities, whose distribution and characteristics may be related to degassing of low-molecular-weight components in the polymer matrix. Conclusion. The two sterilization regimes exerted different levels of thermal impact on the surface microstructure of the photopolymer while maintaining overall structural integrity. The 121°C protocol is recommended as a gentler method for preserving the original morphology of SLA-printed Dental Yellow Clear PRO specimens.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 19-25
The effect of autoclaving conditions on the microstructure of the Dental Yellow Clear PRO photopolymer material produced by stereolithography
Objective. A comparative study of the effect of two clinically acceptable steam sterilization modes on the microstructure of samples made of the domestic photopolymer material Dental Yellow Clear PRO using stereolithography with different layer heights. Material and Methods. Disc-shaped specimens were printed with layer height of 0.05 mm and 0.1 mm and subsequently sterilized using two autoclaving protocols: a “Soft Program” (121°C, 1.1 bar, 15 min) and a “Flash Program S” (134°C, 2.2 bar, 3.5 min). Surface morphology and interlayer integrity were analyzed using field-emission scanning electron microscopy (FE-SEM). Results. Autoclaving did not lead to interlayer delamination or macroscopic structural defects, regardless of layer thickness. Sterilization at 121°C resulted in partial smoothing of interlayer boundaries without signs of substantial material degradation. In contrast, sterilization at 134°C produced more pronounced alterations, including localized surface softening and the formation of microstructural heterogeneities, whose distribution and characteristics may be related to degassing of low-molecular-weight components in the polymer matrix. Conclusion. The two sterilization regimes exerted different levels of thermal impact on the surface microstructure of the photopolymer while maintaining overall structural integrity. The 121°C protocol is recommended as a gentler method for preserving the original morphology of SLA-printed Dental Yellow Clear PRO specimens.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- 22 October 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (5) , 13-18
Comparative analysis of microhardness of polymeric materials for temporary restorations manufactured using different technologies
Objective. Comparative study of the surface hardness of polymer materials for temporary crowns, differing in composition and manufacturing technology, in a dry state and after exposure to an aqueous medium. Material and methods. 4 materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot curing), Tempocor (cold curing). The disc-shaped samples were polished and kept in dry conditions or distilled water (37 °C, 7 days). The Vickers hardness was measured on a Duramin-20 microhardness tester (load 25 g, exposure 15 s). Statistical processing is the Student’s t-test. Results. In the dry state, all materials showed similar hardness (19—22 HV). The smallest decrease in hardness after water was observed in Huge PMMA (<7%) and Sinma-M (~3%). Dental Sand Pro showed a decrease of 12.4%. The maximum drop was in Tempocor (by 17%: from 19.72 to 16.37 HV). Microstructurally, Dental Sand Pro and Tempocor have pores and inhomogeneities. Conclusion. It is most stable in the aquatic environment of Huge PMMA (CAD/CAM). Sinma-M (hot polymerization) also demonstrates high stability. Dental Sand Pro 3D printing material requires optimization of post-polymerization modes. Tempocor (cold curing) is the least water-resistant, and its use for long-term temporary restoration is limited. Surface hardness is an informative criterion for preclinical assessment of the reliability of temporary restorations.
- Open Access
- 22 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Comparative analysis of bone regenerate density when using autogenous and allogeneic ring grafts for augmentation of the alveolar process before dental implantation
INTRODUCTION. Ring grafts permit alveolar ridge augmentation with simultaneous implant placement; comparative longitudinal density data are limited. PURPOSE. To compare bone regenerate density after augmentation with autogenous and allogeneic ring grafts. MATERIALS AND METHODS. A prospective comparative study included 66 patients: 34 received autogenous and 32 allogeneic ring grafts. CBCT measurements were obtained immediately after surgery and after 6 and 12 months. RESULTS. Mean density in the autogenous group was 757, 678 and 825 at the three time points; corresponding values in the allogeneic group were 643, 561 and 680. Density decreased by 6 months and increased by 12 months in both groups. At 12 months, density was higher with autogenous grafts ( p < 0.001). Values are expressed on the study’s CBCT density scale. CONCLUSION. Both groups showed a decrease followed by an increase in radiographic density. The autogenous group had higher mean density at 12 months.
- 22 October 2026
- Published by Khabadze ZS in Эндодонтия Today
Open AccessComparative analysis of bone regenerate density when using autogenous and allogeneic ring grafts for augmentation of the alveolar process before dental implantation
INTRODUCTION. Ring grafts permit alveolar ridge augmentation with simultaneous implant placement; comparative longitudinal density data are limited. PURPOSE. To compare bone regenerate density after augmentation with autogenous and allogeneic ring grafts. MATERIALS AND METHODS. A prospective comparative study included 66 patients: 34 received autogenous and 32 allogeneic ring grafts. CBCT measurements were obtained immediately after surgery and after 6 and 12 months. RESULTS. Mean density in the autogenous group was 757, 678 and 825 at the three time points; corresponding values in the allogeneic group were 643, 561 and 680. Density decreased by 6 months and increased by 12 months in both groups. At 12 months, density was higher with autogenous grafts ( p < 0.001). Values are expressed on the study’s CBCT density scale. CONCLUSION. Both groups showed a decrease followed by an increase in radiographic density. The autogenous group had higher mean density at 12 months.
- Open Access
- 6 October 2026
- Published by Alfmed LLC in Medical alphabet
- No. 20,p. 125-132
Refinement of the surgical protocol for alveolar ridge augmentation using ring grafts and simultaneous implantation
Background. Severe horizontal atrophy of the alveolar ridge is a common obstacle to dental implantation. Existing augmentation methods do not always provide predictable results due to insufficient primary stability and high resorption. Refinement of the surgical protocol using ring grafts and simultaneous implantation remains a relevant task. Aim. To describe and clinically substantiate a refined surgical protocol for augmentation of the mandibular alveolar process using ring grafts and simultaneous dental implantation. Materials and methods. The prospective study included 66 patients (25–65 years) with ridge width Results. No intraoperative complications occurred. Mean ridge width increased from 3.4±0.1 to 10.4±0.4 mm in the autogenous group and from 2.9±0.4 to 11.1±0.3 mm in the allogeneic group. At 6 months, resorption was 11.5% and 27%, respectively (pConclusion. The proposed protocol provides safe and reproducible ridge width augmentation with high implant stability. Autogenous grafts show less long-term resorption, but allogeneic grafts are also acceptable with careful postoperative management.
- 6 October 2026
- Published by Alfmed LLC in Medical alphabet
- No. 20,p. 125-132
Open AccessRefinement of the surgical protocol for alveolar ridge augmentation using ring grafts and simultaneous implantation
Background. Severe horizontal atrophy of the alveolar ridge is a common obstacle to dental implantation. Existing augmentation methods do not always provide predictable results due to insufficient primary stability and high resorption. Refinement of the surgical protocol using ring grafts and simultaneous implantation remains a relevant task. Aim. To describe and clinically substantiate a refined surgical protocol for augmentation of the mandibular alveolar process using ring grafts and simultaneous dental implantation. Materials and methods. The prospective study included 66 patients (25–65 years) with ridge width Results. No intraoperative complications occurred. Mean ridge width increased from 3.4±0.1 to 10.4±0.4 mm in the autogenous group and from 2.9±0.4 to 11.1±0.3 mm in the allogeneic group. At 6 months, resorption was 11.5% and 27%, respectively (pConclusion. The proposed protocol provides safe and reproducible ridge width augmentation with high implant stability. Autogenous grafts show less long-term resorption, but allogeneic grafts are also acceptable with careful postoperative management.
- 30 September 2026
- Published by LLC Science and Innovations in Saratov Medical Journal
- Vol. 7 (2)
Comparative morphological characteristics of bone repair using various bone graft compositions during sinus lift surgery
Objective: Comparative morphometric analysis of bone repair processes in the sinus lift zone using different compositions of bone grafting material. Materials and methods: Morphological and morphometric study of trephine biopsy specimens of bone tissue was performed in three groups of patients 180 days after sinus lift surgery using different compositions of bone grafting material: Group 1 – Cerabone® granules (100%); Group 2 – Cerabone® with autograft bone chips in a 25:75 ratio; Group 3 – Cerabone® with autograft bone chips in a 50:50 ratio. Microscopic picture was assessed on sections stained with hematoxylin and eosin, volume fractions of the main components of the regenerate and cellular activity indices were measured. Results: Direct osteogenesis with the formation of mature cancellous bone was observed in all groups. The highest volume of newly formed bone tissue (BV) was achieved in Group 3 (34.5%), while the lowest one was detected in Group 1 (25.75%). Indices of osteoblastic activity (N.ob, Ob.S) and material integration (MatBS/BS) were also highest in Group 3 (70.2%). Conclusion: The results of our study indicate the advantage of using composite bone grafting materials with a 50:50 ratio of Cerabone® and autogenous bone graft for optimizing bone repair in sinus lift and emphasize the need for morphometric monitoring of the effectiveness of various bone graft compositions in reconstructive surgery.
- 30 September 2026
- Published by LLC Science and Innovations in Saratov Medical Journal
- Vol. 7 (2)
Comparative morphological characteristics of bone repair using various bone graft compositions during sinus lift surgery
Objective: Comparative morphometric analysis of bone repair processes in the sinus lift zone using different compositions of bone grafting material. Materials and methods: Morphological and morphometric study of trephine biopsy specimens of bone tissue was performed in three groups of patients 180 days after sinus lift surgery using different compositions of bone grafting material: Group 1 – Cerabone® granules (100%); Group 2 – Cerabone® with autograft bone chips in a 25:75 ratio; Group 3 – Cerabone® with autograft bone chips in a 50:50 ratio. Microscopic picture was assessed on sections stained with hematoxylin and eosin, volume fractions of the main components of the regenerate and cellular activity indices were measured. Results: Direct osteogenesis with the formation of mature cancellous bone was observed in all groups. The highest volume of newly formed bone tissue (BV) was achieved in Group 3 (34.5%), while the lowest one was detected in Group 1 (25.75%). Indices of osteoblastic activity (N.ob, Ob.S) and material integration (MatBS/BS) were also highest in Group 3 (70.2%). Conclusion: The results of our study indicate the advantage of using composite bone grafting materials with a 50:50 ratio of Cerabone® and autogenous bone graft for optimizing bone repair in sinus lift and emphasize the need for morphometric monitoring of the effectiveness of various bone graft compositions in reconstructive surgery.
- 28 September 2026
- Published by Stomatology for All - International Dental Review in Stomatology for all / International Dental Review
- No. 3(116)
Results of autogenous bone grafting with subsequent dental implantation in patients with insufficient alveolar bone width
The effectiveness of autologous bone grafting with monocortical blocks was analyzed in 50 patients with alveolar bone width deficiency, divided into two groups. The first group (n=26) used the standard technique of autograft fixa-tion, while the second group (n=24) used a modified technique with penetrating osteoperforation of the graft and recipient bed. After 6 months, according to CBCT data, good results were achieved in 50.1 % of patients in the first group and in 91.7 % of the second group. Satisfactory and conditionally satisfactory results in the second group were 8.3 % and 0 %, respectively, versus 33.3 % and 16.6 % in the first group. The presented clinical case confirms the effectiveness of the modified technique, which ensured successful osseointegration of the implants. Penetrating osteoperforation, which improves the contact between the autograft and the recipient bed, is a key factor in achieving predictable and stable results of bone reconstruction.
- 28 September 2026
- Published by Stomatology for All - International Dental Review in Stomatology for all / International Dental Review
- No. 3(116)
Results of autogenous bone grafting with subsequent dental implantation in patients with insufficient alveolar bone width
The effectiveness of autologous bone grafting with monocortical blocks was analyzed in 50 patients with alveolar bone width deficiency, divided into two groups. The first group (n=26) used the standard technique of autograft fixa-tion, while the second group (n=24) used a modified technique with penetrating osteoperforation of the graft and recipient bed. After 6 months, according to CBCT data, good results were achieved in 50.1 % of patients in the first group and in 91.7 % of the second group. Satisfactory and conditionally satisfactory results in the second group were 8.3 % and 0 %, respectively, versus 33.3 % and 16.6 % in the first group. The presented clinical case confirms the effectiveness of the modified technique, which ensured successful osseointegration of the implants. Penetrating osteoperforation, which improves the contact between the autograft and the recipient bed, is a key factor in achieving predictable and stable results of bone reconstruction.
- 12 August 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (4)
The influence of composition and application technology of polymeric materials for temporary restorations in prosthetic dentistry on water sorption and solubility indicators
Objective. Comparative assessment of water absorption and solubility of polymer materials for temporary restorations, differing in composition and technology of application (CAD/CAM, 3D printing, traditional analog method). Materials and methods. Four materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot polymerization) and Tempokor Automix (chemical curing). Samples in the form of discs (n= 4-8 per group) were made according to the requirements of GOST R 71412-2024. Water absorption (p_w) and solubility (p_s) tests were carried out in distilled water at a temperature of 37 ± 1 °C for 7 days. The statistical analysis was performed using the Student’s t-test. Results. Statistically significant intergroup differences were found (p<0.05). The highest water absorption was observed in the Dental Sand Pro 3D printing material (40.04±1.59 micrograms/mm3), which corresponds to the upper limit of the standard value. The values of p_w for Huge PMMA (26.76±1.70 micrograms/mm3) and Sigma-M (24.05±2.65 micrograms/mm3) are below the established limit. The solubility of Sinma-M (11.21±3.17 micrograms/mm3) exceeded the standard value (7.5 micrograms/mm3) and was significantly higher than that of Huge PMMA (0.78±0.16 micrograms/mm3) and Dental Sand Pro (4.32±1.44 micrograms/mm3). The Tempocor material showed satisfactory results in both parameters. Conclusion. The water absorption and solubility of polymer materials for temporary restorations significantly depend on both the chemical composition and the manufacturing technology. Milled PMMA (CAD/CAM) demonstrated the greatest stability, while traditional materials showed high variability in properties. The results obtained should be taken into account in the clinical selection of the material to ensure the long-term success of orthopedic treatment.
- 12 August 2026
- Published by Media Sphere Publishing Group in Stomatology
- Vol. 105 (4)
The influence of composition and application technology of polymeric materials for temporary restorations in prosthetic dentistry on water sorption and solubility indicators
Objective. Comparative assessment of water absorption and solubility of polymer materials for temporary restorations, differing in composition and technology of application (CAD/CAM, 3D printing, traditional analog method). Materials and methods. Four materials were studied: Huge PMMA (CAD/CAM), Dental Sand Pro (3D printing), Sinma-M (hot polymerization) and Tempokor Automix (chemical curing). Samples in the form of discs (n= 4-8 per group) were made according to the requirements of GOST R 71412-2024. Water absorption (p_w) and solubility (p_s) tests were carried out in distilled water at a temperature of 37 ± 1 °C for 7 days. The statistical analysis was performed using the Student’s t-test. Results. Statistically significant intergroup differences were found (p<0.05). The highest water absorption was observed in the Dental Sand Pro 3D printing material (40.04±1.59 micrograms/mm3), which corresponds to the upper limit of the standard value. The values of p_w for Huge PMMA (26.76±1.70 micrograms/mm3) and Sigma-M (24.05±2.65 micrograms/mm3) are below the established limit. The solubility of Sinma-M (11.21±3.17 micrograms/mm3) exceeded the standard value (7.5 micrograms/mm3) and was significantly higher than that of Huge PMMA (0.78±0.16 micrograms/mm3) and Dental Sand Pro (4.32±1.44 micrograms/mm3). The Tempocor material showed satisfactory results in both parameters. Conclusion. The water absorption and solubility of polymer materials for temporary restorations significantly depend on both the chemical composition and the manufacturing technology. Milled PMMA (CAD/CAM) demonstrated the greatest stability, while traditional materials showed high variability in properties. The results obtained should be taken into account in the clinical selection of the material to ensure the long-term success of orthopedic treatment.
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 184-191
Results of applying the method of bone plastic surgery before subsequent dental implantation
This study represents a comprehensive comparative analysis aimed at a comprehensive assessment of the clinical efficacy of two fundamentally different methods of guided bone regeneration. These surgical interventions, performed on patients with severe alveolar bone atrophy, serve as a preparatory stage before dental implantation, the results of which directly impact the long-term success of orthopedic treatment. The study examines an innovative approach that utilizes pre-designed, patient-specific, bioresorbable 3D scaffolds. These scaffolds are manufactured from a modified tricalcium phosphate composite with tailored osteoconductive and osteoinductive properties using advanced additive manufacturing technology known as rapid prototyping. The clinical portion of the study, based on prospective observation and statistical analysis of the data obtained, demonstrates the high efficacy of the proposed proprietary method. The key performance criterion was bone volume gain in the atrophied alveolar ridge. A quantitative assessment using dynamic computed tomography (CT) revealed an increase in alveolar ridge height ranging from 35 to 43 percent relative to baseline values, which statistically significantly exceeds the results achieved in the control group, which used standard barrier membranes and granulated osteoplastic materials. Based on a comprehensive analysis of clinical observations, including an assessment of postoperative healing, the incidence of complications, and radiographic monitoring data confirming the formation of a mature, vascularized bone structure with optimal density, a substantiated conclusion has been reached. The use of customized, bioresorbable, three-dimensional structures is not only technically feasible but also a highly promising, scientifically proven strategy in modern maxillofacial surgery and dental implantology. This technique allows us to address complex clinical challenges associated with significant bone loss, ultimately opening up new possibilities for the comprehensive rehabilitation of patients with significant alveolar bone atrophy.
- 4 July 2026
- Published by Clinical Dentistry in Clinical Dentistry (Russia)
- Vol. 29 (2) , 184-191
Results of applying the method of bone plastic surgery before subsequent dental implantation
This study represents a comprehensive comparative analysis aimed at a comprehensive assessment of the clinical efficacy of two fundamentally different methods of guided bone regeneration. These surgical interventions, performed on patients with severe alveolar bone atrophy, serve as a preparatory stage before dental implantation, the results of which directly impact the long-term success of orthopedic treatment. The study examines an innovative approach that utilizes pre-designed, patient-specific, bioresorbable 3D scaffolds. These scaffolds are manufactured from a modified tricalcium phosphate composite with tailored osteoconductive and osteoinductive properties using advanced additive manufacturing technology known as rapid prototyping. The clinical portion of the study, based on prospective observation and statistical analysis of the data obtained, demonstrates the high efficacy of the proposed proprietary method. The key performance criterion was bone volume gain in the atrophied alveolar ridge. A quantitative assessment using dynamic computed tomography (CT) revealed an increase in alveolar ridge height ranging from 35 to 43 percent relative to baseline values, which statistically significantly exceeds the results achieved in the control group, which used standard barrier membranes and granulated osteoplastic materials. Based on a comprehensive analysis of clinical observations, including an assessment of postoperative healing, the incidence of complications, and radiographic monitoring data confirming the formation of a mature, vascularized bone structure with optimal density, a substantiated conclusion has been reached. The use of customized, bioresorbable, three-dimensional structures is not only technically feasible but also a highly promising, scientifically proven strategy in modern maxillofacial surgery and dental implantology. This technique allows us to address complex clinical challenges associated with significant bone loss, ultimately opening up new possibilities for the comprehensive rehabilitation of patients with significant alveolar bone atrophy.
- 30 June 2026
- Published by LLC Science and Innovations in Saratov Journal of Medical Scientific Research
- Vol. 22 (2)
Comparative morphological characteristics of reparative osteogenesis using diferent compositions of bone plastic material during sinus-lifting
Objective: A morphological and morphometric study of trepanobioptates of bone tissue was performed in patients of three groups 180 days after sinus lift surgery using diferent compositions of osteoplastic material: group 1 – Cerabone granules (100%); group 2 – Cerabone with autobone shavings in the ratio of 25%/75%; group 3 – Cerabone with autobone shavings in the ratio of 50%/50%. Material and methods. The microscopic picture was evaluated on hematoxylin and eosin-stained sections, the volume fractions of the main components of the regenerate and the indicators of cellular activity were determined. Results. It was found that all groups showed direct osteogenesis with the formation of mature spongy bone. The highest volume of newly formed bone tissue (BV) was achieved in group III (34.5%), while the lowest was achieved in group I (25.75%). The indicators of osteoblastic activity (N.ob, Ob.S) and material integration (MatBS/BS) were also highest in group III (70.2%). Conclusion. The obtained data indicate the advantage of using combined bone-plastic materials with an equal ratio of Cerabone and autologous bone to optimize reparative osteogenesis during sinus lifting and emphasize the need for morphometric control of the efectiveness of various compositions of osteoplastic materials in reconstructive surgery.
- 30 June 2026
- Published by LLC Science and Innovations in Saratov Journal of Medical Scientific Research
- Vol. 22 (2)
Comparative morphological characteristics of reparative osteogenesis using diferent compositions of bone plastic material during sinus-lifting
Objective: A morphological and morphometric study of trepanobioptates of bone tissue was performed in patients of three groups 180 days after sinus lift surgery using diferent compositions of osteoplastic material: group 1 – Cerabone granules (100%); group 2 – Cerabone with autobone shavings in the ratio of 25%/75%; group 3 – Cerabone with autobone shavings in the ratio of 50%/50%. Material and methods. The microscopic picture was evaluated on hematoxylin and eosin-stained sections, the volume fractions of the main components of the regenerate and the indicators of cellular activity were determined. Results. It was found that all groups showed direct osteogenesis with the formation of mature spongy bone. The highest volume of newly formed bone tissue (BV) was achieved in group III (34.5%), while the lowest was achieved in group I (25.75%). The indicators of osteoblastic activity (N.ob, Ob.S) and material integration (MatBS/BS) were also highest in group III (70.2%). Conclusion. The obtained data indicate the advantage of using combined bone-plastic materials with an equal ratio of Cerabone and autologous bone to optimize reparative osteogenesis during sinus lifting and emphasize the need for morphometric control of the efectiveness of various compositions of osteoplastic materials in reconstructive surgery.