IUInga Uriadnikova

Inga Uriadnikova

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Inga Uriadnikova has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adaptive management of cascading failure risks in water treatment systems of thermal power enterprises

    by Inga Uriadnikova

    Under conditions of systemic instability and growing military threats to critical infrastructure facilities, the development of a methodology for adaptive risk management of cascading failures in water treatment systems is of particular importance for ensuring their survivability and protecting thermal power equipment. Traditional reliability assessment methods may be insufficient for accounting for the cascading nature of transient processes in technological installations, where a local failure may propagate to adjacent system components and lead to deterioration in the quality of the heat-transfer medium. To ensure the survivability of water treatment systems and protect thermal power equipment under conditions of military and technogenic instability, a methodology for adaptive risk management of cascading failures has been developed based on reliability theory and Kolmogorov differential equations. Analysis of the developed mathematical approach made it possible to establish that: 1) a mathematical model of system-state dynamics was developed based on Kolmogorov differential equations, in which the transition rates between states depend on the adaptive control vector, thereby enabling the occurrence of a cascading failure to be formalized as a probabilistic transition between system states; 2) a method was proposed for determining the adaptive control parameters of an electrocoagulation unit by minimizing deviations of water-treatment quality indicators from their specified values while simultaneously accounting for specific energy consumption; 3) an approach was developed for the quantitative assessment of an adaptive resilience index characterizing the preservation of system functionality throughout the disturbance period–from the onset of failure to the restoration of the specified treatment parameters; 4) a mathematical approach was proposed for determining instantaneous and integral adaptive risk as the expected value of system-related technological losses, thereby enabling the identification of potentially vulnerable elements of the technological scheme; 5) it was substantiated that adaptive management of electrocoagulation units may contribute to the localization of cascading failures, the maintenance of stable treated-water quality, and a reduction in the risk of damage to thermal power equipment caused by disturbances in the water-chemical regime. Quantitative assessment of the effectiveness of the proposed approach requires further mathematical modelling and experimental verification.

  • Open Access

    Formalization of multiplicative risks in transient processes within water supply systems of thermal power enterprises

    by Inga Uriadnikova

    Under conditions of systemic instability and increasing military threats to critical infrastructure, the mathematical formalization of multiplicative risks in high-load inertial water supply systems of thermal power plants has become particularly relevant. Traditional reliability assessment methods fail to account for the cascading nature of transients in compact technological units, where limited internal volume accelerates the hydrodynamic shock phase, and delays in parameter control lead to non-linear growth of destructive consequences. Analysis of technical failure scenarios indicates that risk is formed as a result of the synergistic interaction between a power trigger, the dynamic vulnerability function, and dynamic pressure. To ensure the dynamic parametric adaptability of equipment, this study develops a mathematical approach to formalizing multiplicative risk, integrating inertial flow coast-down parameters and the millisecond response time of protection systems. The study establishes the integral risk model, based on the determination of the system's «vulnerability window», allowing for a quantitative assessment of the transition from local failure to the cascading destruction of electrocoagulation unit components. Modeling results demonstrate that: 1) the proposed approach enables the identification of the critical impact of protection systems' response time on the peak shock amplitude, which significantly refines the resilience limits of compact systems; 2) the introduction of an exponential vulnerability function provides a justification for the required automation response time to break the accident cascade; 3) the model proves the advantages of a preventive time-parameter management strategy as the basis for dynamic parametric adaptability over increasing the physical strength of structures; 4) the application of the model creates a foundation for designing systems capable of maintaining functionality under wartime energy deficits; 5) the developed approach establishes a methodological framework for the modernization of Ukraine's thermal power facilities, aimed at minimizing technogenic losses in crisis modes.

  • Open Access

    Integrated assessment of technogenic risks in water supply systems of thermal power enterprises under military threats

    by Inga Uriadnikova

    Under conditions of increasing instability and elevated threats to critical infrastructure, issues related to technogenic risk management in water supply systems of thermal power enterprises are becoming particularly relevant. Disruptions in their operation caused by technogenic accidents, natural impacts, and military threats may lead to significant economic, environmental, and social consequences, necessitating a transition from reactive approaches to proactive risk management. An analysis of recent accidents and infrastructure damage indicates that risk is formed as a result of the interaction between the probability of hazardous events, the severity of their consequences, and the level of system preparedness to withstand such threats. To enhance the effectiveness of technogenic risk management, this study develops a mathematical approach that integrates the assessment of event probabilities, consequence severity, and the effectiveness of management measures, taking into account the synergistic effects of their simultaneous implementation. Within the framework of the research, an integral risk model is formulated, enabling a quantitative evaluation of the impact of individual technogenic and military threats on the operation of water supply systems in thermal power engineering and the identification of an optimal set of measures for risk minimization under limited resource conditions. The analysis of the modeling results demonstrates that: 1) the proposed approach allows for the quantitative incorporation of the severity of consequences of accident-related and military events, significantly improving the objectivity of integral risk assessment; 2) the introduction of an effectiveness indicator for management measures enables the evaluation of their impact on risk reduction and the comparison of alternative management strategies; 3) the model facilitates the identification of critical elements of water supply systems that are most vulnerable to technogenic and military threats, thereby ensuring the prioritization of their protection and reinforcement; 4) the application of optimization methods provides a sound basis for rational resource allocation and enhanced system resilience under crisis conditions; and 5) the proposed approach establishes a foundation for the development of strategies aimed at improving the safety and reliability of water supply systems in thermal power engineering, reducing the negative consequences of technogenic accidents and military threats, and ensuring the sustainable operation of critical infrastructure under conditions of high uncertainty.

  • Open Access

    Determination of criteria for assessing the resilience and vulnerability of water treatment systems for effective risk management

    by Inga Uriadnikova

    Current issues in the field of water supply, especially for critical infrastructure facilities, such as water treatment systems, are not only increasing the efficiency of production processes and reducing energy costs, but also ensuring their stability and vulnerability in the face of multiple external threats. Analysis of the causes of industrial accidents and damage, as well as the consequences of natural disasters and military actions, shows that the disruption of the functioning of water treatment systems is characterized by a combination of random events that occur with different frequency and intensity at different stages of their operation. In order to determine and substantiate the criteria for quantitatively assessing the stability and vulnerability of the functioning of water treatment systems under the influence of threats of a technogenic, natural and military nature for effective risk management in water treatment systems, a study was conducted that included the division of the concept of reliability into internal reliability, stability and vulnerability. Analysis of the results obtained showed that: 1) the concept of reliability assessment has been expanded. The study proved the necessity and possibility of integrating the concepts of resilience and vulnerability into the traditional assessment of the reliability of water treatment systems, which provides a more complete picture of the complex reliability of functioning in conditions of diverse external threats (technogenic, natural, military); 2) a system of quantitative resilience criteria was developed, and an approach was formed, and mathematical dependencies were derived for an objective quantitative assessment of overall resilience. This indicator combines partial coefficients characterizing the specific resistance to each type of threat, as well as the coefficient of recovery capabilities, which reflects the system's ability to quickly recover; 3) The criteria for quantitative assessment of vulnerability are determined and mathematical dependencies for calculating the vulnerability of the system are substantiated and presented, which allows not only to generally assess the system's susceptibility to negative consequences, but also to identify specific «weak links» through the analysis of partial vulnerability criteria; 4) the practical value of the approach for effective risk management is substantiated. The proposed criteria provide an objective toolkit for effective risk management in water treatment systems and allow reasonably focusing attention on protective measures and investments, directing resources to the most vulnerable parts of the system that require priority strengthening; 5) the created basis for effective security management provides for the possibility of quantitative assessment of stability and vulnerability, which ensures the development and implementation of security improvement strategies for the purpose of sustainable and uninterrupted water supply in conditions of growing uncertainty and potential threats.

  • Response Plan Elaboration for Potential Military Emergencies Caused by External Pollutants of Water Sources

    by Volodymyr Kobylianskyi, Oleksandr Kravchenko, Kateryna Sorokina, Inga Uriadnikova


  • Open Access

    Analysis of the interrelationship between error dynamics and the overall risk level in the opera-tion of water treatment systems

    by Inga Uriadnikova

    Today, ensuring reliable and safe operation of water treatment systems that are part of critical infrastructure is one of the key tasks of environmental and technogenic safety. Despite the perfection of modern technologies, no complex engineering system operates in conditions of complete stability – constant variability of the parameters of the source water, fluctuations in the activity of reagents, inertia of processes and other factors lead to errors in the operation of individual functional units. These errors, even under normal operation, form deviations that can negatively affect the resulting quality of purified water. Their accumulation or underestimation of potential damage increases the risks of violating sanitary and technical standards and creates a threat to the environment. In order to study the scientific and methodological approach to the analysis of the relationship between the dynamics of errors in the functioning of water treatment systems and the formation of the overall risk level, the paper gradually analyzed errors in water treatment systems and their direct relationship with risks, the relationship with transfer functions and recovery time, and developed a mathematical apparatus for quantitative assessment and risk management. Analysis of the results obtained showed that the errors that arise at each technological stage are not isolated, but are summed up and transformed throughout the water treatment chain, which leads to the formation of the resulting error and directly affects the compliance of water quality with standards. It is established that the probability of exceeding critical water quality indicators directly depends on the resulting error, which, in turn, is a function of the standard deviations of the errors of individual blocks and the confidence coefficient (t). It has been proven that the scale of consequences is functionally dependent on the duration of the problem (Tproblem), which includes the detection time (Tdetection), the response time (Tresponse) and, most importantly, the restoration time (Trecovery) of the functionality of the water treatment system. The use of transfer functions in combination with the Laplace transform provides the possibility of dynamic modeling of the transmission and accumulation of errors in the time domain, as well as their impact on the parameters of the Tproblem. The developed integrated risk formula provides a mathematical apparatus for quantitative assessment and risk management, combining the statistical characteristics of the block errors and the operational parameters of the system's response to deviations.

  • Open Access

    Research on the interrelationship between reliability, risks and safety of water treatment systems

    by Inga Uriadnikova

    Today, water treatment systems in thermal power plants are an integral part of the technological process, since the quality of the prepared water directly affects the efficiency of boiler and heat exchange equipment. Water used in thermal power must meet strict regulatory requirements, since even minor deviations can lead to corrosion of metal surfaces, scale formation and a decrease in heat exchange efficiency. In order to study the analysis of the relationship between the reliability, risks and safety of operation of water treatment equipment in thermal power plants, it is proposed to develop mathematical models for assessing the reliability of water treatment systems in thermal power plants, which will allow formalizing the processes of failure occurrence, their elimination and impact on the stability and efficiency of water treatment equipment. Analysis of the results obtained showed that the use of mathematical models allows not only to quantitatively assess the reliability of water treatment systems in thermal power plants, but also to identify patterns that determine their durability, stability of operation and level of safety. The calculations confirmed that there is a close relationship between the probability of failure-free operation, failure intensity, mean time without failure and the efficiency of the system as a whole. The results obtained indicate that a significant reduction in the risks of emergency situations can be achieved by increasing the speed of equipment recovery, which directly affects the reduction of downtime, which, in turn, contributes to increasing the overall efficiency of the system, reducing water and energy losses, as well as minimizing the negative impact on the production process. The study also confirmed that the relationship between reliability, risks and safety of the system has a significant impact on its operational characteristics. In particular, systems with a higher level of reliability demonstrate a lower probability of failures, which has a positive effect on the overall efficiency of thermal power enterprises. The proposed mathematical expressions allow predicting the operability of equipment over a certain period of time, assessing the impact of variable parameters on the stability of the system and making informed decisions on its improvement. The analysis confirmed the effectiveness of using mathematical methods to assess the reliability and safety of water treatment systems.

  • Open Access

    Use of logical-graphic methods of analysis of risks in the water supply systems of thermal power plants

    by Inga Uriadnikova

    Today's urgent issues in the water supply of thermal power plants are increasing the efficiency of production processes, reducing energy costs, introducing innovative technologies, as well as ensuring environmental safety and sustainable development. The analysis of the causes of industrial accidents and damages shows that the occurrence and development of accidents, as a rule, is characterized by a combination of random local events that occur with different frequency at different stages of the accident. Logical-graphic methods of fault trees and events are used to identify cause-and-effect relationships between these events. In order to investigate the identification and analysis of cause-and-effect relationships that contribute to the occurrence of failures in the water treatment system using a fault tree for the further development of effective measures to minimize risks and increase the reliability and safety of the water supply systems of thermal power plants, it is proposed to use logical-graphic methods on the previous stage of identification and assessment of technogenic risks. The analysis of the obtained results showed that: 1) the fault tree is an instantaneous display of the system at a certain moment in time t and is a graphical representation of the cause-and-effect relationships obtained as a result of identifying dangerous situations in the system in a forward and reverse order in order to find possible causes of their occurrence; 2) a complex final event should be determined using the so-called «tree top». The top of the tree consists of the final event and additional undesirable events, including potential accidents and dangerous conditions that are direct causes of the final event. The final event and additional events must be carefully defined and all the most important causes of the final event identified. Therefore, the first five heuristic rules must be used when building a rejection tree; 3) construction of a fault tree using heuristic rules can be used when considering any element of the system, however, to simplify cumbersome constructions, it is more appropriate to build trees only for the main elements that cause emergency situations and have a negative impact on people's lives and health, as well as on environment; 4) when building a fault trees for the technological scheme of water treatment, it is possible to specify and quantify events, to find events with a very high probability and a very low probability, to limit the further development of the fault trees and to establish the causes of failures at each stage of the water treatment process; 5) the rejection tree can be used for quantitative assessments using Markov models.


  • Open Access

    Determination of technogenic risks when using various water purification technologies

    by Inga Uriadnikova, Viktor Khoruzhy, Tetiana Arhatenko

    In modern conditions, ensuring the reliability and safety of water supply systems is a primary task for the industrial economy and the safety of life of the population of Ukraine. Constant bombing and damage to critical infrastructure facilities, including water management facilities, endangers the stability and quality of the country's water resources. In this context, conducting research on the identification of man-made risks in water treatment systems using various technologies, as well as developing strategies to increase the reliability and safety of operation of water supply systems are becoming relevant for the industrial sector of Ukraine. In order to increase the reliability of water treatment units and their operational safety, man-made risks were investigated when using ion exchange, electrodialysis, and water distillation technologies at thermal power plants. It is shown that during normal operation of the ion-exchange water purification system with an average productivity of 400 m3/h, in the case of frequent changes in the concentration of salts at the inlet, the risk of receiving underpurified water is 0.0783. This value must be taken into account for the assessment of economic and social-ecological risks, since it exceeds the generally accepted value of 0.01. When using electrodialysis water purification and frequent changes in the concentration of salts at the inlet, the risk of receiving underpurified water is 0.0271. This value is also greater than 0.01 risk accepted as acceptable. The water distillation technology has enough margin to compensate for any deviations in the purification process and gives a very low risk. However, the distillation process is more effective in removing only soluble impurities, while in the case of suspended substances, in particular of organic origin, there is a risk of exceeding the limit of 0.01.

  • Open Access

    Assessment of the reliability оf operation of water purification system units in transitional modes

    by Inga Uriadnikova, Victor Khoruzhy

    Забезпечення безперебійності та надійності роботи систем водоочищення є пріоритетним завданням промислового комплексу України. Для ефективного управління надійністю в системах водоочищення, необхідно провести аналіз потенційних відмовлень та визначити ймовірність їх виникнення. З метою дослідження визначення імовірності виникнення ризиків у результаті відмовлень різних блоків системи водоочищення на прикладі роботи електорокоагулятору колонного типу запропоновано для одержання узагальнених закономірностей використовувати структурно-функціональну блок-схему систем водоочищення, що дає можливість звести всю систему до декількох взаємозалежних блоків, а саме: 1) блоком фільтрації тонкого очищення; 2) блоком очищення від розчинних домішок; 3) блоком очищення від грубодисперсних домішок; 4) трубо-насосним блоком. При роботі системи водоочищення, з огляду на ранжирування надійності блоків можна стверджувати, що на початку може вийти з роботи 1-ій блок, далі 2, 3 і 4 блоки. Встановлено, якщо всі блоки системи працюють, система знаходиться в стані S0. При відмовленнях інших блоків, у тій же послідовності, система буде в станах S1, S2, S3 і S4. Найбільший інтерес представляють стани системи, при яких відмовлення блоків викликають не відключення всієї системи, а лише її позаштатну роботу, що виявляється лише в наслідку погіршення якості очищуваної води. Аналізуючи отримані результати можна стверджувати, що при експлуатації системи водоочищення найбільша ймовірність відмовлення в блоку 1. Після відновлення працездатності блоку і при подальшій експлуатації системи, найбільша імовірність виходу з ладу блоку 2, потім блоку 4 і блоку 3. Імовірності відмовлення блоків є ймовірностями ризиків, причому фізична величина, породжувана цими ризиками (кількість забрудненої води, що надійшла у екосистему чи в котлоагрегат) буде тим більшою, чим більше період часу виявлення несправності блоку. При досить тривалій роботі системи водоочищення в неї встановлюється ймовірнісний постійний режим переходу зі стану в стан за схемою “робочий стан усіх блоків – відмовлення одного чи декількох блоків – ремонт – робочий стан усіх блоків“. Імовірності послідовності і тривалості цих подій піддаються визначенню, що дає можливість з однієї сторони оцінювати ризики, що виникають при експлуатації і визначати стратегію управління для мінімізації цих ризиків.