Seth D. Billings
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seth D. Billings has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Arathy Kartha
SUNY College of Optometry, New York, New York, United States
2 shared publications - Breanne Christie
Johns Hopkins University Applied Physics Laboratory
2 shared publications - Francesco V. Tenore
Johns Hopkins University Applied Physics Laboratory
2 shared publications - Gislin Dagnelie
Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, Maryland, United States
2 shared publications - Roberta L. Klatzky
Carnegie Mellon University
2 shared publications - Alexandra L. Patterson
Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD, USA
1 shared publication
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Nanotechnology Magazine
- Vol. 20 (2) , 42-50
Seeing With Sound
Thousands of people worldwide are affected by diseases that cause degenerative vision loss leading to permanent blindness while the crucial cells for sight, retinal ganglion cells (RGCs), remain intact and functioning. Image information may be sent through the functioning RGCs to the visual cortex of the brain by exciting them with ultrasound from an epiretinal implant made from a polymer matrix nanocomposite (PMNC) engineered to provide a laser-induced photoacoustic response. The implant has the geometry of a double layer where the layers consist of a PMNC and a neat polymer (without nanoparticles). The PMNC is made of palladium-doped polydimethylsiloxane produced using a chemical vapor deposition-based process. The effective properties of the PMNC depend on the properties of the nanoparticles (including their size, number density and distribution) along with those of the polymer matrix. In this work, the acoustic output of the PMNC was experimentally captured with a high frequency hydrophone. The temperature rise in the near particle region of the PMNC from a single pulse was estimated to be 890°C/(mJ/mm2) based on the adiabatic temperature rise in a particle while the temperature rise in the bulk composite from a pulse train was estimated to be 563°C/(mW) and 69°C/(mW) at the front and back sides of the PMNC, respectively. These established temperature limits are key factors for designing accelerated reliability testing of the implant that is needed to evaluate reliability of the material in its use as a retinal prosthetic.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Nanotechnology Magazine
- Vol. 20 (2) , 42-50
Seeing With Sound
Thousands of people worldwide are affected by diseases that cause degenerative vision loss leading to permanent blindness while the crucial cells for sight, retinal ganglion cells (RGCs), remain intact and functioning. Image information may be sent through the functioning RGCs to the visual cortex of the brain by exciting them with ultrasound from an epiretinal implant made from a polymer matrix nanocomposite (PMNC) engineered to provide a laser-induced photoacoustic response. The implant has the geometry of a double layer where the layers consist of a PMNC and a neat polymer (without nanoparticles). The PMNC is made of palladium-doped polydimethylsiloxane produced using a chemical vapor deposition-based process. The effective properties of the PMNC depend on the properties of the nanoparticles (including their size, number density and distribution) along with those of the polymer matrix. In this work, the acoustic output of the PMNC was experimentally captured with a high frequency hydrophone. The temperature rise in the near particle region of the PMNC from a single pulse was estimated to be 890°C/(mJ/mm2) based on the adiabatic temperature rise in a particle while the temperature rise in the bulk composite from a pulse train was estimated to be 563°C/(mW) and 69°C/(mW) at the front and back sides of the PMNC, respectively. These established temperature limits are key factors for designing accelerated reliability testing of the implant that is needed to evaluate reliability of the material in its use as a retinal prosthetic.
- Open Access
- 26 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Autonomous multisensory enhancement of a visual neuroprosthesis for navigation: Technical proof-of-concept with simulated prosthetic vision and single-subject case study of a visual prosthesis user
Objective: Visual impairments create significant challenges for navigation. This work explored the potential for an autonomous navigation aid with multisensory feedback to improve navigational performance for users of visual neuroprostheses. Approach: An autonomous navigation system was developed that maps the environment in real time and provides guidance using combinations of prosthetic vision, haptic, and auditory cues. Navigational performance was evaluated in 20 sighted participants using simulated prosthetic vision and in a single-subject case study of an Argus II visual neuroprosthesis user. Participants completed three tasks: navigate to destination, obstacle field traversal, and relative distance judgment. Multiple sensory feedback configurations incorporating visual, haptic, and auditory cues were compared. Performance metrics included collision rate, distance traveled, task completion time, navigation success rate, and accuracy of relative distance judgements. Main results: Performance differences across sensory configurations were most pronounced in navigation success and collision rates. Haptic plus audio feedback was highly effective for navigation tasks, enabling successful navigation in nearly all trials involving haptic guidance. Argus vision alone was inadequate for navigation. Depth vision provided modest improvements over Argus vision but did not enhance performance beyond haptic and audio guidance when combined. Wide field-of-view depth vision yielded additional benefits, particularly for obstacle field traversal where its performance exceeded other modes. Adding Argus vision to haptic and audio also provided no benefit and, in some cases, degraded performance. Performance trends for the Argus user were generally comparable to those of sighted participants across sensory modes, with the exception of the relative distance judgement task, in which the Argus user demonstrated better performance. Among sighted participants, increased field of view and resolution independently improved relative distance judgment accuracy. Significance: These findings demonstrate the potential of multimodal feedback systems to improve navigation for prosthetic vision users. (ClinicalTrials.gov NCT04359108)
- 26 January 2026
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 23 (1)
Open AccessAutonomous multisensory enhancement of a visual neuroprosthesis for navigation: Technical proof-of-concept with simulated prosthetic vision and single-subject case study of a visual prosthesis user
Objective: Visual impairments create significant challenges for navigation. This work explored the potential for an autonomous navigation aid with multisensory feedback to improve navigational performance for users of visual neuroprostheses. Approach: An autonomous navigation system was developed that maps the environment in real time and provides guidance using combinations of prosthetic vision, haptic, and auditory cues. Navigational performance was evaluated in 20 sighted participants using simulated prosthetic vision and in a single-subject case study of an Argus II visual neuroprosthesis user. Participants completed three tasks: navigate to destination, obstacle field traversal, and relative distance judgment. Multiple sensory feedback configurations incorporating visual, haptic, and auditory cues were compared. Performance metrics included collision rate, distance traveled, task completion time, navigation success rate, and accuracy of relative distance judgements. Main results: Performance differences across sensory configurations were most pronounced in navigation success and collision rates. Haptic plus audio feedback was highly effective for navigation tasks, enabling successful navigation in nearly all trials involving haptic guidance. Argus vision alone was inadequate for navigation. Depth vision provided modest improvements over Argus vision but did not enhance performance beyond haptic and audio guidance when combined. Wide field-of-view depth vision yielded additional benefits, particularly for obstacle field traversal where its performance exceeded other modes. Adding Argus vision to haptic and audio also provided no benefit and, in some cases, degraded performance. Performance trends for the Argus user were generally comparable to those of sighted participants across sensory modes, with the exception of the relative distance judgement task, in which the Argus user demonstrated better performance. Among sighted participants, increased field of view and resolution independently improved relative distance judgment accuracy. Significance: These findings demonstrate the potential of multimodal feedback systems to improve navigation for prosthetic vision users. (ClinicalTrials.gov NCT04359108)
- Open Access
Sequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only
Objective Electrical stimulation of the retina can elicit flashes of light called phosphenes, which can be used to restore rudimentary vision for people with blindness. Functional sight requires stimulation of multiple electrodes to create patterned vision, but phosphenes tend to merge together in an uninterpretable way. Sequentially stimulating electrodes in human visual cortex has recently demonstrated that shapes could be “drawn” with better perceptual resolution relative to simultaneous stimulation. The goal of this study was to evaluate if sequential stimulation would also form clearer shapes when the retina is the neural target. Approach Two human participants with retinitis pigmentosa who had Argus® II retinal prostheses participated in this study. We evaluated different temporal parameters for sequential stimulation in phosphene shape mapping and forced-choice discrimination tasks. For the discrimination tasks, performance was compared between stimulating electrodes simultaneously versus sequentially. Main results Phosphenes elicited by different electrodes were reported as vastly different shapes. Sequential electrode stimulation outperformed simultaneous stimulation in simple discrimination tasks, in which shapes were created by stimulating 3-4 electrodes, but not in more complex discrimination tasks involving 5+ electrodes. For sequential stimulation, the optimal pulse train duration was 200 ms when stimulating at 20 Hz and the optimal gap interval was tied between 0 and 50 ms. Efficacy of sequential stimulation also depended strongly on selecting electrodes that elicited phosphenes with similar shapes and sizes. Significance An epiretinal prosthesis can produce coherent simple shapes with a sequential stimulation paradigm, which can be used as rudimentary visual feedback. However, success in creating more complex shapes, such as letters of the alphabet, is still limited. Sequential stimulation may be most beneficial for epiretinal prostheses in simple tasks, such as basic navigation, rather than complex tasks such as object identification.
Open AccessSequential epiretinal stimulation improves discrimination in simple shape discrimination tasks only
Objective Electrical stimulation of the retina can elicit flashes of light called phosphenes, which can be used to restore rudimentary vision for people with blindness. Functional sight requires stimulation of multiple electrodes to create patterned vision, but phosphenes tend to merge together in an uninterpretable way. Sequentially stimulating electrodes in human visual cortex has recently demonstrated that shapes could be “drawn” with better perceptual resolution relative to simultaneous stimulation. The goal of this study was to evaluate if sequential stimulation would also form clearer shapes when the retina is the neural target. Approach Two human participants with retinitis pigmentosa who had Argus® II retinal prostheses participated in this study. We evaluated different temporal parameters for sequential stimulation in phosphene shape mapping and forced-choice discrimination tasks. For the discrimination tasks, performance was compared between stimulating electrodes simultaneously versus sequentially. Main results Phosphenes elicited by different electrodes were reported as vastly different shapes. Sequential electrode stimulation outperformed simultaneous stimulation in simple discrimination tasks, in which shapes were created by stimulating 3-4 electrodes, but not in more complex discrimination tasks involving 5+ electrodes. For sequential stimulation, the optimal pulse train duration was 200 ms when stimulating at 20 Hz and the optimal gap interval was tied between 0 and 50 ms. Efficacy of sequential stimulation also depended strongly on selecting electrodes that elicited phosphenes with similar shapes and sizes. Significance An epiretinal prosthesis can produce coherent simple shapes with a sequential stimulation paradigm, which can be used as rudimentary visual feedback. However, success in creating more complex shapes, such as letters of the alphabet, is still limited. Sequential stimulation may be most beneficial for epiretinal prostheses in simple tasks, such as basic navigation, rather than complex tasks such as object identification.