Alexandra L. Patterson
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alexandra L. Patterson has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Dajie Zhang
Air and Missile Defense Sector, Johns Hopkins Applied Physics Laboratory, Laurel, MD, USA
1 shared publication Emad M. Boctor
Electrical and Computer Engineering Department and the Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA
1 shared publication- Hyunwoo Song
Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, MD, USA
1 shared publication - James B. Spicer
Department of Materials Science and Engineering, The Johns Hopkins University, 3400 North Charles Street, Baltimore, Maryland 21218, USA
1 shared publication - Seth D. Billings
Research and Exploratory Development Department, Johns Hopkins Applied Physics Laboratory, Laurel, MD, USA
1 shared publication
Latest Publications
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Nanotechnology Magazine
- Vol. 20 (2) , 42-50
Seeing With Sound
Thousands of people worldwide are affected by diseases that cause degenerative vision loss leading to permanent blindness while the crucial cells for sight, retinal ganglion cells (RGCs), remain intact and functioning. Image information may be sent through the functioning RGCs to the visual cortex of the brain by exciting them with ultrasound from an epiretinal implant made from a polymer matrix nanocomposite (PMNC) engineered to provide a laser-induced photoacoustic response. The implant has the geometry of a double layer where the layers consist of a PMNC and a neat polymer (without nanoparticles). The PMNC is made of palladium-doped polydimethylsiloxane produced using a chemical vapor deposition-based process. The effective properties of the PMNC depend on the properties of the nanoparticles (including their size, number density and distribution) along with those of the polymer matrix. In this work, the acoustic output of the PMNC was experimentally captured with a high frequency hydrophone. The temperature rise in the near particle region of the PMNC from a single pulse was estimated to be 890°C/(mJ/mm2) based on the adiabatic temperature rise in a particle while the temperature rise in the bulk composite from a pulse train was estimated to be 563°C/(mW) and 69°C/(mW) at the front and back sides of the PMNC, respectively. These established temperature limits are key factors for designing accelerated reliability testing of the implant that is needed to evaluate reliability of the material in its use as a retinal prosthetic.
- 23 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Nanotechnology Magazine
- Vol. 20 (2) , 42-50
Seeing With Sound
Thousands of people worldwide are affected by diseases that cause degenerative vision loss leading to permanent blindness while the crucial cells for sight, retinal ganglion cells (RGCs), remain intact and functioning. Image information may be sent through the functioning RGCs to the visual cortex of the brain by exciting them with ultrasound from an epiretinal implant made from a polymer matrix nanocomposite (PMNC) engineered to provide a laser-induced photoacoustic response. The implant has the geometry of a double layer where the layers consist of a PMNC and a neat polymer (without nanoparticles). The PMNC is made of palladium-doped polydimethylsiloxane produced using a chemical vapor deposition-based process. The effective properties of the PMNC depend on the properties of the nanoparticles (including their size, number density and distribution) along with those of the polymer matrix. In this work, the acoustic output of the PMNC was experimentally captured with a high frequency hydrophone. The temperature rise in the near particle region of the PMNC from a single pulse was estimated to be 890°C/(mJ/mm2) based on the adiabatic temperature rise in a particle while the temperature rise in the bulk composite from a pulse train was estimated to be 563°C/(mW) and 69°C/(mW) at the front and back sides of the PMNC, respectively. These established temperature limits are key factors for designing accelerated reliability testing of the implant that is needed to evaluate reliability of the material in its use as a retinal prosthetic.