Joseph G. Shuttleworth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joseph G. Shuttleworth has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Gary Richard Mirams
Centre for Mathematical Medicine and Biology, School of Mathematical Sciences, University of Nottingham, Nottingham, United Kingdom
5 shared publications - Adam P. Hill
Victor Chang Cardiac Research Institute, Sydney, Australia
3 shared publications - Chon Lok Lei
Institute of Translational Medicine, Faculty of Health Sciences, University of Macau
3 shared publications - Dominic G. Whittaker
University of Nottingham
3 shared publications - Monique J. Windley
Computational Cardiology Laboratory, Victor Chang Cardiac Research Institute
3 shared publications - Simon P. Preston
School of Mathematical Sciences University of Nottingham UK
3 shared publications
Latest Publications
- Open Access
A general mathematical framework for modelling subnetworks of the nuclear auxin pathway
Auxins are a family of plant hormones involved in various processes across plant tissues and species. The Nuclear Auxin Pathway (NAP) consists of interacting transcription factors (ARFs) and repressors (Aux/IAAs), which govern an individual cell’s response to changes in auxin concentration. These components are present in all land plants, and many species possess multiple copies of each signalling component. We present a general framework for ODE-based models of NAP submodules with the flexibility to model the promotion and repression of target genes by any combination of transcriptional regulators. We analyse published data and show that auxin treatment in Arabidopsis thaliana roots triggers a range of characteristically distinct temporal response profiles—for both target genes and the signalling components themselves. Using our modelling framework, we recapitulate aspects of this behaviour by presenting examples of real and theoretical NAP subnetworks, and by analysing the effect that these network dynamics have on auxin-mediated transcriptional responses. This work demonstrates the utility of our modelling framework as a general-purpose tool for understanding the function of certain protein-protein and protein-DNA interactions through their effects on the NAP. This exploration of the rich dynamics of more complex signalling pathways promises to advance our understanding of the NAP.
Open AccessA general mathematical framework for modelling subnetworks of the nuclear auxin pathway
Auxins are a family of plant hormones involved in various processes across plant tissues and species. The Nuclear Auxin Pathway (NAP) consists of interacting transcription factors (ARFs) and repressors (Aux/IAAs), which govern an individual cell’s response to changes in auxin concentration. These components are present in all land plants, and many species possess multiple copies of each signalling component. We present a general framework for ODE-based models of NAP submodules with the flexibility to model the promotion and repression of target genes by any combination of transcriptional regulators. We analyse published data and show that auxin treatment in Arabidopsis thaliana roots triggers a range of characteristically distinct temporal response profiles—for both target genes and the signalling components themselves. Using our modelling framework, we recapitulate aspects of this behaviour by presenting examples of real and theoretical NAP subnetworks, and by analysing the effect that these network dynamics have on auxin-mediated transcriptional responses. This work demonstrates the utility of our modelling framework as a general-purpose tool for understanding the function of certain protein-protein and protein-DNA interactions through their effects on the NAP. This exploration of the rich dynamics of more complex signalling pathways promises to advance our understanding of the NAP.
- Open Access
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240211
Evaluating the predictive accuracy of ion-channel models using data from multiple experimental designs
Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue; that is, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to the central pore of its primary protein having a propensity to blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiment designs (protocols) to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually and quantify the error in the resultant model predictions for other protocols. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant effect on our parameter estimates and suggests routes for model improvement. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- 13 March 2025
- Published by The Royal Society in Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences
- Vol. 383 (2292) , 20240211
Open AccessEvaluating the predictive accuracy of ion-channel models using data from multiple experimental designs
Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue; that is, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to the central pore of its primary protein having a propensity to blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiment designs (protocols) to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually and quantify the error in the resultant model predictions for other protocols. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant effect on our parameter estimates and suggests routes for model improvement. This article is part of the theme issue ‘Uncertainty quantification for healthcare and biological systems (Part 1)’.
- Open Access
Evaluating the predictive accuracy of ion channel models using data from multiple experimental designs
Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue - namely, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to its central pore's propensity for blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiments to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually, and quantify the error in the resultant model predictions. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant impact on our parameter estimates and suggests routes for model improvement.
Open AccessEvaluating the predictive accuracy of ion channel models using data from multiple experimental designs
Mathematical models are increasingly being relied upon to provide quantitatively accurate predictions of cardiac electrophysiology. Many such models concern the behaviour of particular subcellular components (namely, ion channels) which, together, allow the propagation of electrical signals through heart-muscle tissue - namely, the firing of action potentials. In particular, I Kr , a voltage-sensitive potassium ion-channel current, is of interest owing to its central pore's propensity for blockage by various small molecules. We use newly collected data obtained from an ensemble of voltage-clamp experiments to validate the predictive accuracy of various dynamical models of I Kr . To do this, we fit models to each protocol individually, and quantify the error in the resultant model predictions. This allows the comparison of predictive accuracy for I Kr models under a diverse collection of previously unexplored dynamics. Our results highlight heterogeneity between parameter estimates obtained from different cells, suggesting the presence of latent effects not yet accounted for in our models. This heterogeneity has a significant impact on our parameter estimates and suggests routes for model improvement.
- Open Access
- 24 November 2023
- Published by Springer Nature in Bulletin of Mathematical Biology
- Vol. 86 (1) , 1-36
Empirical Quantification of Predictive Uncertainty Due to Model Discrepancy by Training with an Ensemble of Experimental Designs: An Application to Ion Channel Kinetics
When using mathematical models to make quantitative predictions for clinical or industrial use, it is important that predictions come with a reliable estimate of their accuracy (uncertainty quantification). Because models of complex biological systems are always large simplifications, model discrepancy arises—models fail to perfectly recapitulate the true data generating process. This presents a particular challenge for making accurate predictions, and especially for accurately quantifying uncertainty in these predictions. Experimentalists and modellers must choose which experimental procedures (protocols) are used to produce data used to train models. We propose to characterise uncertainty owing to model discrepancy with an ensemble of parameter sets, each of which results from training to data from a different protocol. The variability in predictions from this ensemble provides an empirical estimate of predictive uncertainty owing to model discrepancy, even for unseen protocols. We use the example of electrophysiology experiments that investigate the properties of hERG potassium channels. Here, ‘information-rich’ protocols allow mathematical models to be trained using numerous short experiments performed on the same cell. In this case, we simulate data with one model and fit it with a different (discrepant) one. For any individual experimental protocol, parameter estimates vary little under repeated samples from the assumed additive independent Gaussian noise model. Yet parameter sets arising from the same model applied to different experiments conflict—highlighting model discrepancy. Our methods will help select more suitable ion channel models for future studies, and will be widely applicable to a range of biological modelling problems.
- 24 November 2023
- Published by Springer Nature in Bulletin of Mathematical Biology
- Vol. 86 (1) , 1-36
Open AccessEmpirical Quantification of Predictive Uncertainty Due to Model Discrepancy by Training with an Ensemble of Experimental Designs: An Application to Ion Channel Kinetics
When using mathematical models to make quantitative predictions for clinical or industrial use, it is important that predictions come with a reliable estimate of their accuracy (uncertainty quantification). Because models of complex biological systems are always large simplifications, model discrepancy arises—models fail to perfectly recapitulate the true data generating process. This presents a particular challenge for making accurate predictions, and especially for accurately quantifying uncertainty in these predictions. Experimentalists and modellers must choose which experimental procedures (protocols) are used to produce data used to train models. We propose to characterise uncertainty owing to model discrepancy with an ensemble of parameter sets, each of which results from training to data from a different protocol. The variability in predictions from this ensemble provides an empirical estimate of predictive uncertainty owing to model discrepancy, even for unseen protocols. We use the example of electrophysiology experiments that investigate the properties of hERG potassium channels. Here, ‘information-rich’ protocols allow mathematical models to be trained using numerous short experiments performed on the same cell. In this case, we simulate data with one model and fit it with a different (discrepant) one. For any individual experimental protocol, parameter estimates vary little under repeated samples from the assumed additive independent Gaussian noise model. Yet parameter sets arising from the same model applied to different experiments conflict—highlighting model discrepancy. Our methods will help select more suitable ion channel models for future studies, and will be widely applicable to a range of biological modelling problems.
- Open Access
- 10 August 2022
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 19 (193) , 20220193
Ion channel model reduction using manifold boundaries
Mathematical models of voltage-gated ion channels are used in basic research, industrial and clinical settings. These models range in complexity, but typically contain numerous variables representing the proportion of channels in a given state, and parameters describing the voltage-dependent rates of transition between states. An open problem is selecting the appropriate degree of complexity and structure for an ion channel model given data availability. Here, we simplify a model of the cardiac human Ether-à-go-go related gene (hERG) potassium ion channel, which carries cardiac I Kr , using the manifold boundary approximation method (MBAM). The MBAM approximates high-dimensional model-output manifolds by reduced models describing their boundaries, resulting in models with fewer parameters (and often variables). We produced a series of models of reducing complexity starting from an established five-state hERG model with 15 parameters. Models with up to three fewer states and eight fewer parameters were shown to retain much of the predictive capability of the full model and were validated using experimental hERG1a data collected in HEK293 cells at 37°C. The method provides a way to simplify complex models of ion channels that improves parameter identifiability and will aid in future model development.
- 10 August 2022
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 19 (193) , 20220193
Open AccessIon channel model reduction using manifold boundaries
Mathematical models of voltage-gated ion channels are used in basic research, industrial and clinical settings. These models range in complexity, but typically contain numerous variables representing the proportion of channels in a given state, and parameters describing the voltage-dependent rates of transition between states. An open problem is selecting the appropriate degree of complexity and structure for an ion channel model given data availability. Here, we simplify a model of the cardiac human Ether-à-go-go related gene (hERG) potassium ion channel, which carries cardiac I Kr , using the manifold boundary approximation method (MBAM). The MBAM approximates high-dimensional model-output manifolds by reduced models describing their boundaries, resulting in models with fewer parameters (and often variables). We produced a series of models of reducing complexity starting from an established five-state hERG model with 15 parameters. Models with up to three fewer states and eight fewer parameters were shown to retain much of the predictive capability of the full model and were validated using experimental hERG1a data collected in HEK293 cells at 37°C. The method provides a way to simplify complex models of ion channels that improves parameter identifiability and will aid in future model development.
- Open Access
Ion channel model reduction using manifold boundaries
Mathematical models of voltage-gated ion channels are used in basic research, industrial and clinical settings. These models range in complexity, but typically contain numerous variables representing the proportion of channels in a given state, and parameters describing the voltage-dependent rates of transition between states. An open problem is selecting the appropriate degree of complexity and structure for an ion channel model given data availability. Here, we simplify a model of the cardiac human Ether-à-go-go Related Gene (hERG) potassium ion channel, which carries cardiac I Kr , using the manifold boundary approximation method (MBAM). The MBAM approximates high-dimensional model-output manifolds by reduced models describing their boundaries, resulting in models with fewer parameters (and often variables). We produced a series of models of reducing complexity starting from an established 5-state hERG model with 15 parameters. Models with up to 3 fewer states and 8 fewer parameters were shown to retain much of the predictive capability of the full model and were validated using experimental hERG1a data collected in HEK293 cells at 37°C. The method provides a way to simplify complex models of ion channels that improves parameter identifiability and will aid in future model development.
Open AccessIon channel model reduction using manifold boundaries
Mathematical models of voltage-gated ion channels are used in basic research, industrial and clinical settings. These models range in complexity, but typically contain numerous variables representing the proportion of channels in a given state, and parameters describing the voltage-dependent rates of transition between states. An open problem is selecting the appropriate degree of complexity and structure for an ion channel model given data availability. Here, we simplify a model of the cardiac human Ether-à-go-go Related Gene (hERG) potassium ion channel, which carries cardiac I Kr , using the manifold boundary approximation method (MBAM). The MBAM approximates high-dimensional model-output manifolds by reduced models describing their boundaries, resulting in models with fewer parameters (and often variables). We produced a series of models of reducing complexity starting from an established 5-state hERG model with 15 parameters. Models with up to 3 fewer states and 8 fewer parameters were shown to retain much of the predictive capability of the full model and were validated using experimental hERG1a data collected in HEK293 cells at 37°C. The method provides a way to simplify complex models of ion channels that improves parameter identifiability and will aid in future model development.