Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Seiji Onitsuka has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    General Information and Applications of Najuta Fenestrated Stent Grafts for Aortic Arch Aneurysms

    by Seiji Onitsuka, Atsuhisa Tanaka, Hiroyuki Otsuka, Yusuke Shintani, Ryo Kanamoto, Shinya Negoto, Eiki Tayama

    Endovascular stent graft repair was developed to minimize the invasiveness of open surgery for thoracic and abdominal aortic diseases. This approach involves covering the diseased segment with a stented artificial graft. However, in thoracic endovascular aortic repair (TEVAR) for aortic arch diseases, special consideration is needed to preserve the aortic arch vessels. Standard stent grafts often require additional procedures, such as bypass surgery, to reconstruct the arch vessels. The semi-custom-made Najuta fenestrated stent graft was developed to address this issue. It is a three-dimensional patient-specific stent graft with fenestrations that allow for the preservation of the arch vessels. This study discusses the unique features of the Najuta stent graft and the techniques for its deployment, and it provides an analysis of treatment outcomes based on the current literature.


  • Open Access

    Efficacy and Clinical Application of Najuta Fenestrated Stent Grafts in Aortic Arch Aneurysm Repair

    by Seiji Onitsuka, Atsuhisa Tanaka, Hiroyuki Otsuka, Yusuke Shintani, Ryo Kanamoto, Shinya Negoto, Eiki Tayama

    Endovascular stent graft repair was developed to minimize the invasiveness of open surgery for thoracic and abdominal aortic diseases. This approach involves covering the diseased segment with a stented artificial graft. However, in thoracic endovascular aortic repair (TEVAR) for aortic arch diseases, special consideration is needed to preserve the aortic arch vessels. Traditional stent grafts often require additional procedures, such as bypass surgery, to reconstruct the arch vessels. The semi-custom-made Najuta fenestrated stent graft was developed to address this issue. It is a three-dimensional patient-specific stent graft with fenestrations that allow for the preservation of the arch vessels. This study discusses the unique features of the Najuta stent graft and the techniques for its deployment and provides an analysis of treatment outcomes based on the current literature.


  • Open Access

    Surgical Treatment of Sac Enlargement Due to Type II Endoleaks Following Endovascular Aneurysm Repair

    by Seiji Onitsuka, Hiroyuki Ito

    An aneurysm sac enlargement caused by type II endoleak (T2EL) following endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms may cause serious complications such as rupture. Consequently, methods that preoperatively prevent or postoperatively treat T2EL have been employed. When significant aneurysm enlargement occurs due to persistent T2EL, embolization is first performed through several access points. However, although these endovascular reinterventions have a high technical success rate and are safe, their effectiveness remains questionable. When such endovascular procedures fail to stabilize sac enlargement, open surgical conversion (OSC) becomes the last-resort treatment option. We review several strategies of OSC for the repair of T2EL following EVAR. Among the three main OSC procedures, namely, complete endograft removal, partial endograft removal, and complete endograft preservation, partial endograft removal under infrarenal clamping was considered the most appropriate owing to its less invasiveness and durability.


  • Outcomes of the Gore Excluder Iliac Branch Endoprosthesis for Japanese Patients With Aortoiliac Aneurysms: A Study Based on J-Preserve Registry

    by Yukihisa Ogawa, Naoki Fujimura, Masato Yamaguchi, Hiroshi Banno, Tadashi Furuyama, Terutoshi Yamaoka, Makoto Sumi, Tetsuya Fukuda, Noriyasu Morikage, Etsuji Sohgawa, et al.

    Purpose: To evaluate the clinical utility of the Gore Excluder iliac branch endoprosthesis (IBE) for Japanese patients with aortoiliac aneurysms. Materials and Methods: This was a multicenter retrospective cohort study (J-Preserve Registry). Patients undergoing endovascular aortic repair using the Gore Excluder IBE for aortoiliac aneurysms between August 2017 and June 2020 were enrolled. Data pertaining to the baseline and anatomical characteristics, technical details, and clinical outcomes were collected from each institution. The primary endpoints were technical success, IBE-related complications, and reinterventions. Secondary endpoints were mortality, aneurysm size change, and reintervention during follow-up. Technical success was defined as accurate deployment of the IBE without type Ib, Ic, or III endoleaks on the IBE sides on completion angiography. A change in aneurysm size of 5 mm or more was taken to be a significant change. Results: We included 141 patients with 151 IBE implantations. Sixty-five IBE implantations (43.0%) had at least one instruction for use violation. Twenty-two patients (15.6%) required internal iliac artery (IIA) embolization for external iliac artery extension on the contralateral side. Of 151 IBE implantations, 19 exhibited IIA branch landing zones due to IIA aneurysms. Mean maximum and proximal common iliac artery (CIA) diameters were 32.9±9.9 mm and 20.5±6.9 mm, respectively. The mean CIA length was 59.1±17.1 mm. The IIA landing diameter and length were 9.0±2.3 mm and 33.8±14.6 mm. The overall technical success rate was 96.7%. There were no significant differences in IBE-related complications (2.3% vs 5.3%, p=0.86) or IBE-related reinterventions (1.5% vs 5.3%, p=0.33) between the IIA trunk and IIA branch landing groups. The mean follow-up period was 635±341 days. The all-cause mortality rate was 5.0%. There were no aneurysm-related deaths or ruptures during the follow-up. Most patients (95.7%) had sac stability or shrinkage. Conclusion: The Gore Excluder IBE was safe and effective for Japanese patients in the midterm. Extending the IIA device into the distal branches of the IIA was acceptable, which may permit extending indications for endovascular aortic aneurysm repair of aortoiliac aneurysms to more complex lesions. Clinical Impact: This study suggests clinical benefits of the Gore Excluder IBE for Japanese patients, despite 43% of the IBE implantations having at least one IFU violation.


  • Early Clinical Outcomes of Initial Launch of the Zenith Alpha Abdominal Endovascular Graft in Japan

    by Naoki Fujimura, Shigeo Ichihashi, Hideaki Obara, Toshihisa Asakura, Masatoshi Komooka, Seiji Onitsuka, Yoshihiko Kurimoto, Hiroaki Kato, Takao Ohki

    Purpose: This study retrospectively evaluated the 12-month outcomes of the Zenith Alpha Abdominal Endovascular graft (Zenith Alpha AAA, Cook, Inc, Bloomington, Indiana), which was launched partially in Japan in March 2019, starting with 9 selected sites. Methods: A retrospective analysis was performed of all endovascular aneurysm repairs (EVAR) for abdominal aortic aneurysms using the Zenith Alpha AAA. Late complications were defined as any aneurysm-related events occurring >30 days after EVAR, including an aneurysm sac enlargement of >5 mm and any reinterventions performed. Endoleaks without sac enlargement or reinterventions were excluded from late complications. Results: During the study period, 79 EVARs using the Zenith Alpha AAA were performed. The mean age was 76.6±6.9 years old, 91.1% of patients were male, and the mean aneurysm diameter was 51.1±7.5 mm. Instructions for use violation was observed in 27 patients (34.2%), most frequently being a severely angulated proximal neck (>60°). There were 4 intraoperative complications, including 2 unintentional partial renal artery coverages caused by the premature anchoring of the exposed suprarenal stent barb to the aortic wall, which was a result of the design change of the top cap deletion. Since it was a partial coverage without flow impairment and since renal stenting was unsuccessful, it was left untreated and had no subsequent renal function impairment. During the mean follow-up of 444±123 days, 74 patients completed 12 months of follow-up. Freedom from late complications at 12 months was 90.8%, which included 2 limb occlusions (2.5%). Of 71 patients with a 12-month computed tomography scan, there was only 1 type 1a endoleak (1.3%), 1 sac enlargement of >5 mm (1.3%), and an aneurysm sac shrinkage of >5 mm was observed in 42.2% of patients. There was no type 3 endoleak during the follow-up. Conclusions: This study demonstrated that the new generation of low-profile Zenith Alpha AAA has satisfactory early clinical outcomes, comparable to those obtained with the conventional Zenith endovascular graft. Long-term follow-up is needed to determine whether these favorable outcomes persist.