Outcomes of the Gore Excluder Iliac Branch Endoprosthesis for Japanese Patients With Aortoiliac Aneurysms: A Study Based on J-Preserve Registry
- 11 July 2022
- journal article
- research article
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 31 (1) , 55-61
Abstract
Purpose: To evaluate the clinical utility of the Gore Excluder iliac branch endoprosthesis (IBE) for Japanese patients with aortoiliac aneurysms. Materials and Methods: This was a multicenter retrospective cohort study (J-Preserve Registry). Patients undergoing endovascular aortic repair using the Gore Excluder IBE for aortoiliac aneurysms between August 2017 and June 2020 were enrolled. Data pertaining to the baseline and anatomical characteristics, technical details, and clinical outcomes were collected from each institution. The primary endpoints were technical success, IBE-related complications, and reinterventions. Secondary endpoints were mortality, aneurysm size change, and reintervention during follow-up. Technical success was defined as accurate deployment of the IBE without type Ib, Ic, or III endoleaks on the IBE sides on completion angiography. A change in aneurysm size of 5 mm or more was taken to be a significant change. Results: We included 141 patients with 151 IBE implantations. Sixty-five IBE implantations (43.0%) had at least one instruction for use violation. Twenty-two patients (15.6%) required internal iliac artery (IIA) embolization for external iliac artery extension on the contralateral side. Of 151 IBE implantations, 19 exhibited IIA branch landing zones due to IIA aneurysms. Mean maximum and proximal common iliac artery (CIA) diameters were 32.9±9.9 mm and 20.5±6.9 mm, respectively. The mean CIA length was 59.1±17.1 mm. The IIA landing diameter and length were 9.0±2.3 mm and 33.8±14.6 mm. The overall technical success rate was 96.7%. There were no significant differences in IBE-related complications (2.3% vs 5.3%, p=0.86) or IBE-related reinterventions (1.5% vs 5.3%, p=0.33) between the IIA trunk and IIA branch landing groups. The mean follow-up period was 635±341 days. The all-cause mortality rate was 5.0%. There were no aneurysm-related deaths or ruptures during the follow-up. Most patients (95.7%) had sac stability or shrinkage. Conclusion: The Gore Excluder IBE was safe and effective for Japanese patients in the midterm. Extending the IIA device into the distal branches of the IIA was acceptable, which may permit extending indications for endovascular aortic aneurysm repair of aortoiliac aneurysms to more complex lesions. Clinical Impact: This study suggests clinical benefits of the Gore Excluder IBE for Japanese patients, despite 43% of the IBE implantations having at least one IFU violation.Keywords
This publication has 20 references indexed in Scilit:
- Outcomes of Endovascular Repair for Abdominal Aortic AneurysmsAnnals of Surgery, 2019
- The Society for Vascular Surgery practice guidelines on the care of patients with an abdominal aortic aneurysmJournal of Vascular Surgery, 2018
- Prospective, multicenter study of endovascular repair of aortoiliac and iliac aneurysms using the Gore Iliac Branch EndoprosthesisJournal of Vascular Surgery, 2017
- Zenith Bifurcated Iliac Side Branch Device: Mid-term Results and Assessment of Risk Factors for Intraoperative ThrombosisAnnals of Vascular Surgery, 2017
- Outcomes of Endovascular Repair of Aortoiliac Aneurysms and Analyses of Anatomic Suitability for Internal Iliac Artery Preserving Devices in Japanese PatientsCirculation Journal, 2017
- Use of Iliac Branch Devices for Endovascular Repair of Aneurysmal Distal Seal Zones After EVARJournal of Endovascular Therapy, 2014
- Hypogastric and subclavian artery patency affects onset and recovery of spinal cord ischemia associated with aortic endograftingJournal of Vascular Surgery, 2014
- Family history of aortic disease predicts disease patterns and progression and is a significant influence on management strategies for patients and their relativesJournal of Vascular Surgery, 2013
- Technical Considerations and Performance of Bridging Stent-Grafts for Iliac Side Branched Devices Based on a Pooled Analysis of Single-Center ExperiencesJournal of Endovascular Therapy, 2012
- Solitary aneurysms of the iliac arterial system: An estimate of their frequency of occurrenceJournal of Vascular Surgery, 1989