Jingru Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jingru Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Genyuan Xing
Key Laboratory of Geophysical Exploration Equipment, College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
1 shared publication Guangda Liu
College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China
1 shared publicationJie Liu
College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China
1 shared publication- Xuan Cao
Department of Ocean Observation and Detection, Laoshan Laboratory, Qingdao, China
1 shared publication Xufei Ji
College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China
1 shared publication- Yan Liu
Institute of Oceanographic Instrumentation, Qilu University of Technology (Shandong Academy of Sciences), Qingdao, China
1 shared publication
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Novel Measurement Method of Electromechanical Coupling in Portable Electromagnetic Vibroseis
Developing electromagnetic vibroseis is an important approach to achieving portable seismic sources for shallow seismic exploration. As an electromechanical device, the performance of the portable electromagnetic vibroseis is determined by its internal electromechanical coupling. Obtaining the force factor distribution curve BL(x) is the basis of studying the electromechanical coupling. Existing methods, such as finite element method and quasi-static method, suffer from reliance on prior information, operational complexity, or limited accuracy. Aiming at these disadvantages in the process of obtaining the BL(x), a novel indirect measurement method is proposed. The proposed method relies solely on acquisition data, including acceleration, displacement, and induced electromotive force (EMF) of the internal driving coils moving in the air gap magnetic field. This approach enables the acquisition of the full-stroke BL(x) in a single, rapid measurement, offering advantages in operational convenience and measurement accuracy. To suppress the noise in motion signals and induced EMF signal, Kalman and Savitzky-Golay (S-G) filtering methods were respectively used. The motion velocity was obtained by integrating filtered acceleration signal, followed by a two-stage calibration process. The BL(t) was obtained by solving the motion velocity and induced EMF. The filtered displacement signal was used to map the BL(t) to full-stroke BL(x). Experiments were carried out based on a portable electromagnetic vibroseis platform. The experimental results show that the average root mean square error (RMSE) of the 12 repeated experiments is 0.3139. Compared to other measurement methods, the proposed method achieves both accuracy and operational convenience in portable electromagnetic vibroseis.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Novel Measurement Method of Electromechanical Coupling in Portable Electromagnetic Vibroseis
Developing electromagnetic vibroseis is an important approach to achieving portable seismic sources for shallow seismic exploration. As an electromechanical device, the performance of the portable electromagnetic vibroseis is determined by its internal electromechanical coupling. Obtaining the force factor distribution curve BL(x) is the basis of studying the electromechanical coupling. Existing methods, such as finite element method and quasi-static method, suffer from reliance on prior information, operational complexity, or limited accuracy. Aiming at these disadvantages in the process of obtaining the BL(x), a novel indirect measurement method is proposed. The proposed method relies solely on acquisition data, including acceleration, displacement, and induced electromotive force (EMF) of the internal driving coils moving in the air gap magnetic field. This approach enables the acquisition of the full-stroke BL(x) in a single, rapid measurement, offering advantages in operational convenience and measurement accuracy. To suppress the noise in motion signals and induced EMF signal, Kalman and Savitzky-Golay (S-G) filtering methods were respectively used. The motion velocity was obtained by integrating filtered acceleration signal, followed by a two-stage calibration process. The BL(t) was obtained by solving the motion velocity and induced EMF. The filtered displacement signal was used to map the BL(t) to full-stroke BL(x). Experiments were carried out based on a portable electromagnetic vibroseis platform. The experimental results show that the average root mean square error (RMSE) of the 12 repeated experiments is 0.3139. Compared to other measurement methods, the proposed method achieves both accuracy and operational convenience in portable electromagnetic vibroseis.
- 1 February 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (2) , 023101
A simplified digital lock-in amplifier for the scanning grating spectrometer
For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.
- 1 February 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (2) , 023101
A simplified digital lock-in amplifier for the scanning grating spectrometer
For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.