JWJingru Wang

Jingru Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jingru Wang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Genyuan Xing

    Key Laboratory of Geophysical Exploration Equipment, College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China

    1 shared publication
  • Guangda Liu

    College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China

    1 shared publication
  • Jie Liu

    College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China

    1 shared publication
  • Xuan Cao

    Department of Ocean Observation and Detection, Laoshan Laboratory, Qingdao, China

    1 shared publication
  • Xufei Ji

    College of Instrumentation and Electrical Engineering, Jilin University, 130021 Changchun, China

    1 shared publication
  • Yan Liu

    Institute of Oceanographic Instrumentation, Qilu University of Technology (Shandong Academy of Sciences), Qingdao, China

    1 shared publication

Latest Publications

  • A Novel Measurement Method of Electromechanical Coupling in Portable Electromagnetic Vibroseis

    by Yuda Chen, Jingru Wang, Xuan Cao, Genyuan Xing, Yan Liu

    Developing electromagnetic vibroseis is an important approach to achieving portable seismic sources for shallow seismic exploration. As an electromechanical device, the performance of the portable electromagnetic vibroseis is determined by its internal electromechanical coupling. Obtaining the force factor distribution curve BL(x) is the basis of studying the electromechanical coupling. Existing methods, such as finite element method and quasi-static method, suffer from reliance on prior information, operational complexity, or limited accuracy. Aiming at these disadvantages in the process of obtaining the BL(x), a novel indirect measurement method is proposed. The proposed method relies solely on acquisition data, including acceleration, displacement, and induced electromotive force (EMF) of the internal driving coils moving in the air gap magnetic field. This approach enables the acquisition of the full-stroke BL(x) in a single, rapid measurement, offering advantages in operational convenience and measurement accuracy. To suppress the noise in motion signals and induced EMF signal, Kalman and Savitzky-Golay (S-G) filtering methods were respectively used. The motion velocity was obtained by integrating filtered acceleration signal, followed by a two-stage calibration process. The BL(t) was obtained by solving the motion velocity and induced EMF. The filtered displacement signal was used to map the BL(t) to full-stroke BL(x). Experiments were carried out based on a portable electromagnetic vibroseis platform. The experimental results show that the average root mean square error (RMSE) of the 12 repeated experiments is 0.3139. Compared to other measurement methods, the proposed method achieves both accuracy and operational convenience in portable electromagnetic vibroseis.


  • A simplified digital lock-in amplifier for the scanning grating spectrometer

    by Jingru Wang, Zhihong Wang, Xufei Ji, Jie Liu, Guangda Liu

    For the common measurement and control system of a scanning grating spectrometer, the use of an analog lock-in amplifier requires complex circuitry and sophisticated debugging, whereas the use of a digital lock-in amplifier places a high demand on the calculation capability and storage space. In this paper, a simplified digital lock-in amplifier based on averaging the absolute values within a complete period is presented and applied to a scanning grating spectrometer. The simplified digital lock-in amplifier was implemented on a low-cost microcontroller without multipliers, and got rid of the reference signal and specific configuration of the sampling frequency. Two positive zero-crossing detections were used to lock the phase of the measured signal. However, measurement method errors were introduced by the following factors: frequency fluctuation, sampling interval, and integer restriction of the sampling number. The theoretical calculation and experimental results of the signal-to-noise ratio of the proposed measurement method were 2055 and 2403, respectively.