Xuan Cao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xuan Cao has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Genyuan Xing
Key Laboratory of Geophysical Exploration Equipment, College of Instrumentation and Electrical Engineering, Jilin University, Changchun, China
1 shared publication - Jingru Wang
Institute of Oceanographic Instrumentation, Qilu University of Technology (Shandong Academy of Sciences), Qingdao, China
1 shared publication - Yan Liu
Institute of Oceanographic Instrumentation, Qilu University of Technology (Shandong Academy of Sciences), Qingdao, China
1 shared publication - Yuda Chen
Department of Ocean Observation and Detection, Laoshan Laboratory, Qingdao, China
1 shared publication
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Novel Measurement Method of Electromechanical Coupling in Portable Electromagnetic Vibroseis
Developing electromagnetic vibroseis is an important approach to achieving portable seismic sources for shallow seismic exploration. As an electromechanical device, the performance of the portable electromagnetic vibroseis is determined by its internal electromechanical coupling. Obtaining the force factor distribution curve BL(x) is the basis of studying the electromechanical coupling. Existing methods, such as finite element method and quasi-static method, suffer from reliance on prior information, operational complexity, or limited accuracy. Aiming at these disadvantages in the process of obtaining the BL(x), a novel indirect measurement method is proposed. The proposed method relies solely on acquisition data, including acceleration, displacement, and induced electromotive force (EMF) of the internal driving coils moving in the air gap magnetic field. This approach enables the acquisition of the full-stroke BL(x) in a single, rapid measurement, offering advantages in operational convenience and measurement accuracy. To suppress the noise in motion signals and induced EMF signal, Kalman and Savitzky-Golay (S-G) filtering methods were respectively used. The motion velocity was obtained by integrating filtered acceleration signal, followed by a two-stage calibration process. The BL(t) was obtained by solving the motion velocity and induced EMF. The filtered displacement signal was used to map the BL(t) to full-stroke BL(x). Experiments were carried out based on a portable electromagnetic vibroseis platform. The experimental results show that the average root mean square error (RMSE) of the 12 repeated experiments is 0.3139. Compared to other measurement methods, the proposed method achieves both accuracy and operational convenience in portable electromagnetic vibroseis.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
A Novel Measurement Method of Electromechanical Coupling in Portable Electromagnetic Vibroseis
Developing electromagnetic vibroseis is an important approach to achieving portable seismic sources for shallow seismic exploration. As an electromechanical device, the performance of the portable electromagnetic vibroseis is determined by its internal electromechanical coupling. Obtaining the force factor distribution curve BL(x) is the basis of studying the electromechanical coupling. Existing methods, such as finite element method and quasi-static method, suffer from reliance on prior information, operational complexity, or limited accuracy. Aiming at these disadvantages in the process of obtaining the BL(x), a novel indirect measurement method is proposed. The proposed method relies solely on acquisition data, including acceleration, displacement, and induced electromotive force (EMF) of the internal driving coils moving in the air gap magnetic field. This approach enables the acquisition of the full-stroke BL(x) in a single, rapid measurement, offering advantages in operational convenience and measurement accuracy. To suppress the noise in motion signals and induced EMF signal, Kalman and Savitzky-Golay (S-G) filtering methods were respectively used. The motion velocity was obtained by integrating filtered acceleration signal, followed by a two-stage calibration process. The BL(t) was obtained by solving the motion velocity and induced EMF. The filtered displacement signal was used to map the BL(t) to full-stroke BL(x). Experiments were carried out based on a portable electromagnetic vibroseis platform. The experimental results show that the average root mean square error (RMSE) of the 12 repeated experiments is 0.3139. Compared to other measurement methods, the proposed method achieves both accuracy and operational convenience in portable electromagnetic vibroseis.