Kashish Kumar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kashish Kumar has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
Alok Singh
2 shared publications- Alok Singh
Maulana Azad National Institute of Technology Department of Mechanical Engineering
2 shared publications - Alok Singh
Mechanical Engineering Department, MANIT, Bhopal, India
2 shared publications Gurubalan Annadurai
2 shared publications- Abdul Aabid
Department of Engineering Management, College of Engineering, Prince Sultan University, Riyadh, Saudi Arabia
1 shared publication - Chanduveetil Ahamed Saleel
Department of Mechanical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia
1 shared publication
Latest Publications
- 27 May 2025
- Published by Elsevier in Renewable Energy
- Vol. 252
Methodology to analyze the feasibility of deep seawater cooling systems
- 27 May 2025
- Published by Elsevier in Renewable Energy
- Vol. 252
Methodology to analyze the feasibility of deep seawater cooling systems
- Open Access
- 27 May 2025
- Published by Elsevier in Solar Compass
- Vol. 15
Experimental investigation on LiCl-KCOOH blend for enhancing hybrid liquid desiccant–vapour compression system performance
- 27 May 2025
- Published by Elsevier in Solar Compass
- Vol. 15
Open AccessExperimental investigation on LiCl-KCOOH blend for enhancing hybrid liquid desiccant–vapour compression system performance
- 27 December 2022
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 55, 102960
Progressive development in hybrid liquid desiccant-vapour compression cooling system: A review
- 27 December 2022
- Published by Elsevier in Sustainable Energy Technologies and Assessments
- Vol. 55, 102960
Progressive development in hybrid liquid desiccant-vapour compression cooling system: A review
- Open Access
- 29 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 15917
Economic and Experimental Assessment of KCOOH Hybrid Liquid Desiccant-Vapor Compression System
A liquid desiccant dehumidification cooling system is a promising, energy-saving, high-efficiency, environmentally friendly technology that maintains thermal comfort effectively indoors by utilizing renewable energy sources or waste heat to enhance system efficiency. In this research, a small-scale (6 kW cooling capacity) hybrid liquid desiccant air-conditioning system (HLDAC) is proposed to evaluate the dehumidification performance of a non-corrosive potassium formate (KCOOH) solution. For this, four input parameters, namely, inlet air flow rate, inlet desiccant temperature, inlet desiccant concentration, and inlet specific air humidity, were selected. Moreover, the different combinations of experiments were designed by employing response surface methodology (RSM) to evaluate the dehumidification performance parameters, namely, dehumidifier latent heat load, coefficient of performance of hybrid system, and moisture removal rate (MRR). Further, a comparative performance analysis between the hybrid system and a standalone vapor compression system (VCS) unit was carried out. The result showed a remarkable increase in coefficient of performance, which was observed at about 28.48% over the standalone VCS unit. Furthermore, the economic assessment of the proposed hybrid system is presented in this paper. Finally, from the economic analysis, it was concluded that the hybrid system had a payback time of 2.65 years compared to the VCS unit.
- 29 November 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (23) , 15917
Open AccessEconomic and Experimental Assessment of KCOOH Hybrid Liquid Desiccant-Vapor Compression System
A liquid desiccant dehumidification cooling system is a promising, energy-saving, high-efficiency, environmentally friendly technology that maintains thermal comfort effectively indoors by utilizing renewable energy sources or waste heat to enhance system efficiency. In this research, a small-scale (6 kW cooling capacity) hybrid liquid desiccant air-conditioning system (HLDAC) is proposed to evaluate the dehumidification performance of a non-corrosive potassium formate (KCOOH) solution. For this, four input parameters, namely, inlet air flow rate, inlet desiccant temperature, inlet desiccant concentration, and inlet specific air humidity, were selected. Moreover, the different combinations of experiments were designed by employing response surface methodology (RSM) to evaluate the dehumidification performance parameters, namely, dehumidifier latent heat load, coefficient of performance of hybrid system, and moisture removal rate (MRR). Further, a comparative performance analysis between the hybrid system and a standalone vapor compression system (VCS) unit was carried out. The result showed a remarkable increase in coefficient of performance, which was observed at about 28.48% over the standalone VCS unit. Furthermore, the economic assessment of the proposed hybrid system is presented in this paper. Finally, from the economic analysis, it was concluded that the hybrid system had a payback time of 2.65 years compared to the VCS unit.
- 24 November 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (9) , 11441-11456
Estimating the Power Saving of KCOOH Liquid Desiccant Dehumidification System Using a Statistical Method
- 24 November 2022
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 48 (9) , 11441-11456
Estimating the Power Saving of KCOOH Liquid Desiccant Dehumidification System Using a Statistical Method
- 7 August 2022
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (3) , 6909-6926
Assessment of dehumidification performance of non-corrosive desiccant in hybrid liquid desiccant-vapour compression system
Air-conditioning (AC) systems, which operate on traditional vapor compression refrigeration (VCR) systems, consume a substantial proportion of the world’s electricity consumed by the building industry. In the scope of decreasing greenhouse gas emissions, energy consumption, heating, ventilation, and air conditioning industries have focused on finding alternatives to electrically operated VCR systems. A combination of a liquid desiccant dehumidification system (LDDS) with a VCR system has been recommended as a superior substitute in warm and moist climates. The focus of this research article is to design and fabricate a small-scale 5 kW hybrid LDDS system by integrating the distinct technologies mentioned above. Additionally, data collected on the vapor pressure of potassium formate (KCOOH) at various solution concentrations and temperatures is being collected to assist in encouraging research and determine the optimal concentration range. In this study, experimental analysis and comparison of dehumidification performance was conducted between two desiccants by analyzing the effects of input variables ( , , and ) on the output response ( , , and ). The results showed that the solution with a 69.92% KCOOH concentration had nearly the same vapor pressure as a solution with a 35% LiCl concentration. Moreover, it was revealed that the lowest values of and and the highest value of yield maximum values of the output responses. At the same combination of input variables, the KCOOH desiccant has a much higher hybrid system coefficient of performance than the LiCl desiccant.- 7 August 2022
- Published by Taylor & Francis in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
- Vol. 44 (3) , 6909-6926
Assessment of dehumidification performance of non-corrosive desiccant in hybrid liquid desiccant-vapour compression system
Air-conditioning (AC) systems, which operate on traditional vapor compression refrigeration (VCR) systems, consume a substantial proportion of the world’s electricity consumed by the building industry. In the scope of decreasing greenhouse gas emissions, energy consumption, heating, ventilation, and air conditioning industries have focused on finding alternatives to electrically operated VCR systems. A combination of a liquid desiccant dehumidification system (LDDS) with a VCR system has been recommended as a superior substitute in warm and moist climates. The focus of this research article is to design and fabricate a small-scale 5 kW hybrid LDDS system by integrating the distinct technologies mentioned above. Additionally, data collected on the vapor pressure of potassium formate (KCOOH) at various solution concentrations and temperatures is being collected to assist in encouraging research and determine the optimal concentration range. In this study, experimental analysis and comparison of dehumidification performance was conducted between two desiccants by analyzing the effects of input variables ( , , and ) on the output response ( , , and ). The results showed that the solution with a 69.92% KCOOH concentration had nearly the same vapor pressure as a solution with a 35% LiCl concentration. Moreover, it was revealed that the lowest values of and and the highest value of yield maximum values of the output responses. At the same combination of input variables, the KCOOH desiccant has a much higher hybrid system coefficient of performance than the LiCl desiccant.- Open Access
- 16 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3441
Comparative Analysis on Dehumidification Performance of KCOOH–LiCl Hybrid Liquid Desiccant Air-Conditioning System: An Energy-Saving Approach
Conventional air conditioners (AC) operate on vapor compression refrigeration (VCR) technology, which is a heavy consumer of electricity, and the used refrigerants harm the environment. In humid and hot areas, a liquid desiccant AC system integrated with a VCR system has been proposed as a better alternative to traditional standalone VCR system, as it is an energy-efficient system that can remove latent air load, air pollutants from the processed air, and it is energy-saving. In this study, a hybrid liquid desiccant air conditioning (LDAC) system with a capacity of 5.5 kW was designed and developed by integrating these two different technologies, and the vapor pressure of potassium formate (KCOOH) solution at different solution temperatures and concentrations were monitored experimentally to determine the optimal concentration range. Moreover, a comparative study was conducted to analyze the dehumidification performance of lithium chloride (LiCl) and KCOOH solutions. Experiments are designed by using Minitab 19 software, which employs the design of an experimental technique through full factorial design by considering four variables, namely, type of desiccant, inlet air flow rate, inlet desiccant temperature, and inlet air humidity. To study and compare dehumidification characteristics of both solutions, three responses were considered, i.e., the coefficient of performance of a hybrid system, the heat load of dehumidifier, and specific humidity change. Experimental results revealed that 70% of KCOOH solution exhibited comparable vapor pressure to that of 36% LiCl solution. Additionally, the dehumidification ability of the KCOOH solution was better than that of the LiCl solutions.
- 16 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (6) , 3441
Open AccessComparative Analysis on Dehumidification Performance of KCOOH–LiCl Hybrid Liquid Desiccant Air-Conditioning System: An Energy-Saving Approach
Conventional air conditioners (AC) operate on vapor compression refrigeration (VCR) technology, which is a heavy consumer of electricity, and the used refrigerants harm the environment. In humid and hot areas, a liquid desiccant AC system integrated with a VCR system has been proposed as a better alternative to traditional standalone VCR system, as it is an energy-efficient system that can remove latent air load, air pollutants from the processed air, and it is energy-saving. In this study, a hybrid liquid desiccant air conditioning (LDAC) system with a capacity of 5.5 kW was designed and developed by integrating these two different technologies, and the vapor pressure of potassium formate (KCOOH) solution at different solution temperatures and concentrations were monitored experimentally to determine the optimal concentration range. Moreover, a comparative study was conducted to analyze the dehumidification performance of lithium chloride (LiCl) and KCOOH solutions. Experiments are designed by using Minitab 19 software, which employs the design of an experimental technique through full factorial design by considering four variables, namely, type of desiccant, inlet air flow rate, inlet desiccant temperature, and inlet air humidity. To study and compare dehumidification characteristics of both solutions, three responses were considered, i.e., the coefficient of performance of a hybrid system, the heat load of dehumidifier, and specific humidity change. Experimental results revealed that 70% of KCOOH solution exhibited comparable vapor pressure to that of 36% LiCl solution. Additionally, the dehumidification ability of the KCOOH solution was better than that of the LiCl solutions.