Tessa Kvist Hansen
Tessa Kvist Hansen has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ruut Peuhkuri
Aalborg University
5 shared publications - Søren Peter Bjarløv
DTU Civil Engineering, Department of Civil Engineering, Technical University of Denmark (DTU), Brovej Building 118, DK-2800 Kgs. Lyngby, Denmark
4 shared publications - Eva Møller
Technical University of Denmark
2 shared publications - Ernst Jan de Place Hansen
Aalborg University
1 shared publication - Eva Birgit Møller
Technical University of Denmark, Brovej 118, 2800, Kgs. Lyngby, Denmark
1 shared publication - Frederik R. Steenstrup
Department of Plastics and Packaging Technology, Danish Technical Institute, 2630 Taastrup, Denmark
1 shared publication
Latest Publications
- 14 December 2024
- Published by Springer Nature
- p. 311-317
CLT Walls: Role of Vapour Barriers and Smart Vapour Retarders for Enhanced Durability
- 14 December 2024
- Published by Springer Nature
- p. 311-317
CLT Walls: Role of Vapour Barriers and Smart Vapour Retarders for Enhanced Durability
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2948 (1) , 020047
Hygrothermal measurements in internally insulated solid masonry wall before and after hydrophobization
Constructions built between 1850 and 1960 comprise a remarkable percentage of the total European building stock and are from a time when there was very little f
- 1 January 2023
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 2948 (1) , 020047
Open AccessHygrothermal measurements in internally insulated solid masonry wall before and after hydrophobization
Constructions built between 1850 and 1960 comprise a remarkable percentage of the total European building stock and are from a time when there was very little f
- Open Access
Performance of Polyethylene Vapor Barrier Systems in Temperate Climates
The performance of nine different vapor barrier systems comprising polyethylene (PE) membranes were assessed. The vapor barrier systems comprised membranes of virgin PE, 100% new PE, regenerated PE and multilayered virgin and regenerated PE. Membranes were joined either with tape suited to the individual system or an adhesive base on butyl rubber. The vapor barrier systems were evaluated and compared using standard laboratory tests. Chemical analytical techniques and physicomechanical tests were used. Mechanical properties were assessed using laboratory tests recommended by the harmonized standard EN 1385. Chemical analyses followed standard laboratory protocols performed with specialized equipment and visual examination. Chemical and mechanical properties were determined before and after exposure to an aging regime comprising 168 days at 70 °C in total. The chemical stability of the plastic present in each membrane was further evaluated after an additional exposure to an aging regime comprising 50 days followed by another 30 days at 70 °C. Additional aging indicated chemical changes in the membrane material with time. However, it was not possible to distinguish between aging properties for membranes containing virgin PE, 100% new PE, regenerated PE or multilayered virgin and regenerated PE.
Open AccessPerformance of Polyethylene Vapor Barrier Systems in Temperate Climates
The performance of nine different vapor barrier systems comprising polyethylene (PE) membranes were assessed. The vapor barrier systems comprised membranes of virgin PE, 100% new PE, regenerated PE and multilayered virgin and regenerated PE. Membranes were joined either with tape suited to the individual system or an adhesive base on butyl rubber. The vapor barrier systems were evaluated and compared using standard laboratory tests. Chemical analytical techniques and physicomechanical tests were used. Mechanical properties were assessed using laboratory tests recommended by the harmonized standard EN 1385. Chemical analyses followed standard laboratory protocols performed with specialized equipment and visual examination. Chemical and mechanical properties were determined before and after exposure to an aging regime comprising 168 days at 70 °C in total. The chemical stability of the plastic present in each membrane was further evaluated after an additional exposure to an aging regime comprising 50 days followed by another 30 days at 70 °C. Additional aging indicated chemical changes in the membrane material with time. However, it was not possible to distinguish between aging properties for membranes containing virgin PE, 100% new PE, regenerated PE or multilayered virgin and regenerated PE.
- Open Access
Danish Dwellings with Cold Attics—Ventilation Rates and Air Exchange between Attic and Dwelling
Naturally ventilated cold attics are traditional in many Danish single-family homes. The moisture balance of these attics is dependent on sufficient ventilation for removal of excess moisture. Moisture is generated in the dwelling below, and transported to attic spaces through convection and diffusion. Therefore, airtight ceilings are vital for reduction of excess moisture, which may yield mould growth in the attic. If mould spores migrate to the dwelling it can cause risk of health concerns for occupants. The presents study includes analysis of tracer gas and temperature/relative humidity measurements, in 30 dwellings/attics. The measurements yielded results of both air change rates in attics and dwellings, as well as air exchange between the two zones. Four of 30 houses, met the recommended air change rate of 0.5 h−1, and only in summer. The air change rate in the attics was found to be higher, and with larger variation compared to the dwelling. Visible mould growth was found in three attics, which all exhibited low air change rates. Air exchange between zones occurred in houses both with and without vapour barriers. The downward air exchange in summer, was however slightly larger in cases without vapour barriers. These results highlight the importance of airtight ceilings for both dwelling and attic performance.
Open AccessDanish Dwellings with Cold Attics—Ventilation Rates and Air Exchange between Attic and Dwelling
Naturally ventilated cold attics are traditional in many Danish single-family homes. The moisture balance of these attics is dependent on sufficient ventilation for removal of excess moisture. Moisture is generated in the dwelling below, and transported to attic spaces through convection and diffusion. Therefore, airtight ceilings are vital for reduction of excess moisture, which may yield mould growth in the attic. If mould spores migrate to the dwelling it can cause risk of health concerns for occupants. The presents study includes analysis of tracer gas and temperature/relative humidity measurements, in 30 dwellings/attics. The measurements yielded results of both air change rates in attics and dwellings, as well as air exchange between the two zones. Four of 30 houses, met the recommended air change rate of 0.5 h−1, and only in summer. The air change rate in the attics was found to be higher, and with larger variation compared to the dwelling. Visible mould growth was found in three attics, which all exhibited low air change rates. Air exchange between zones occurred in houses both with and without vapour barriers. The downward air exchange in summer, was however slightly larger in cases without vapour barriers. These results highlight the importance of airtight ceilings for both dwelling and attic performance.
- Open Access
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 20004
Monitored conditions in wooden wall plates in relation to mold and wood decaying fungi
In historic masonry buildings, wood can be embedded in the walls as storey partition beams, or as supportive wall plates. Half-timbered masonry constructions, or wooden frames, e.g. combined with internal insulation, are other examples of wooden elements. Wood decaying fungi can cause serious damage to wood, which may lose mass and strength, ultimately yielding the risk of collapse. In addition, some fungal species may even be hazardous for occupants. All wood decaying fungi depend on favorable moisture and temperature conditions, although the threshold conditions may vary with various fungal species and types, and state of the wood. To predict the risk of occurrence of wood rot, several models have been developed, however most of these are based on a limited number of experiments, or very specific cases. For these reasons, the applicability of the models to other scenarios (fungal species, wood species) may not be appropriate. Furthermore, another failure mode for wood and moisture, is mold growth, which is initiated at lower moisture levels. An indication of risk of mold growth would indicate problems or risks before the initiation of wood rot. Mold growth does not deteriorate the wood, but is usually equally undesired due to health concerns of occupants. For this reason, there might be places where some mold growth would be acceptable, e.g. embedded beam ends if there is no transfer of air from the moldy area to the indoor air. Therefore, risk of rot could be important. The paper investigates models for mass loss due to wood decay and mold growth based on exposure time to favorable hygrothermal conditions. The investigation is based on inspection of wood samples (wall plates) from a full-scale experimental setup of masonry with embedded wood and monitored conditions, to which the prediction models will be applied. Monitored hygrothermal conditions were implemented in mold and wood decay models, and samples were removed from the test setup. The implemented models yielded high mold index and mass loss, whereas neither mold nor decay was observed in the physical samples. Results indicate that the implemented models, in these cases appear to overestimate the risks of mold and rot in the supportive lath behind the insulation.
- 30 June 2020
- Published by EDP Sciences
- Vol. 172, 20004
Open AccessMonitored conditions in wooden wall plates in relation to mold and wood decaying fungi
In historic masonry buildings, wood can be embedded in the walls as storey partition beams, or as supportive wall plates. Half-timbered masonry constructions, or wooden frames, e.g. combined with internal insulation, are other examples of wooden elements. Wood decaying fungi can cause serious damage to wood, which may lose mass and strength, ultimately yielding the risk of collapse. In addition, some fungal species may even be hazardous for occupants. All wood decaying fungi depend on favorable moisture and temperature conditions, although the threshold conditions may vary with various fungal species and types, and state of the wood. To predict the risk of occurrence of wood rot, several models have been developed, however most of these are based on a limited number of experiments, or very specific cases. For these reasons, the applicability of the models to other scenarios (fungal species, wood species) may not be appropriate. Furthermore, another failure mode for wood and moisture, is mold growth, which is initiated at lower moisture levels. An indication of risk of mold growth would indicate problems or risks before the initiation of wood rot. Mold growth does not deteriorate the wood, but is usually equally undesired due to health concerns of occupants. For this reason, there might be places where some mold growth would be acceptable, e.g. embedded beam ends if there is no transfer of air from the moldy area to the indoor air. Therefore, risk of rot could be important. The paper investigates models for mass loss due to wood decay and mold growth based on exposure time to favorable hygrothermal conditions. The investigation is based on inspection of wood samples (wall plates) from a full-scale experimental setup of masonry with embedded wood and monitored conditions, to which the prediction models will be applied. Monitored hygrothermal conditions were implemented in mold and wood decay models, and samples were removed from the test setup. The implemented models yielded high mold index and mass loss, whereas neither mold nor decay was observed in the physical samples. Results indicate that the implemented models, in these cases appear to overestimate the risks of mold and rot in the supportive lath behind the insulation.
- 1 August 2019
- Published by Elsevier in Energy and Buildings
- Vol. 196, 255-268
The effects of wind-driven rain on the hygrothermal conditions behind wooden beam ends and at the interfaces between internal insulation and existing solid masonry
- 1 August 2019
- Published by Elsevier in Energy and Buildings
- Vol. 196, 255-268
The effects of wind-driven rain on the hygrothermal conditions behind wooden beam ends and at the interfaces between internal insulation and existing solid masonry
- 1 November 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 188, 695-708
Performance of hydrophobized historic solid masonry – Experimental approach
- 1 November 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 188, 695-708
Performance of hydrophobized historic solid masonry – Experimental approach
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 172, 235-248
Long term in situ measurements of hygrothermal conditions at critical points in four cases of internally insulated historic solid masonry walls
- 1 August 2018
- Published by Elsevier in Energy and Buildings
- Vol. 172, 235-248
Long term in situ measurements of hygrothermal conditions at critical points in four cases of internally insulated historic solid masonry walls
- Open Access
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 315-320
Material characterization models and test methods for historic building materials
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 315-320
Open AccessMaterial characterization models and test methods for historic building materials