Aditi Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aditi Jain has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Drew A. Hall
University of California, San Diego
4 shared publications - Asish Koruprolu
Department of Electrical and Computer Engineering, University of California, San Diego, La Jolla, CA, USA
2 shared publications - An Huang
Graduate Institute of Communication Engineering, National Taiwan University, Taipei, Taiwan
1 shared publication Andrew Bourhis
Department of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA, USA
1 shared publication- Anushi Rajapaksa
New Vaccines, Murdoch Children’s Research Institute, Melbourne, Australia
1 shared publication Corentin Pochet
Department of Electrical and Computer Engineering, University of California at San Diego, La Jolla, CA, USA
1 shared publication
Latest Publications
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (5) , 852-875
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Continuous health monitoring by placing sensors onto and into the human body has emerged as a pivotal approach in healthcare. This paper delves into the vast array of opportunities presented by instrumenting the body using wearable, ingestible, injectable, and implantable sensors. These sensors enable the continuous monitoring of vital signs, biomarkers, and other crucial health metrics, thus assessing an individual’s physiological state. This comprehensive health data empowers healthcare providers and individuals alike to make informed decisions and take timely action. Moreover, integrating sensors into the human body enables personalized medicine, enhances disease detection and management, and offers possibilities for proactive health interventions and preventive care to improve overall well-being.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (5) , 852-875
From Wearables to Implantables: Harnessing Sensor Technologies for Continuous Health Monitoring
Continuous health monitoring by placing sensors onto and into the human body has emerged as a pivotal approach in healthcare. This paper delves into the vast array of opportunities presented by instrumenting the body using wearable, ingestible, injectable, and implantable sensors. These sensors enable the continuous monitoring of vital signs, biomarkers, and other crucial health metrics, thus assessing an individual’s physiological state. This comprehensive health data empowers healthcare providers and individuals alike to make informed decisions and take timely action. Moreover, integrating sensors into the human body enables personalized medicine, enhances disease detection and management, and offers possibilities for proactive health interventions and preventive care to improve overall well-being.
- 18 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (3) , 894-907
A 2.5–20 kS/s In-Pixel Direct Digitization ECoG Front End With Submillisecond Stimulation Artifact Recovery
Neural stimulation is used routinely to diagnose and treat neurological disorders. The stimulation artifacts are, however, problematic for closed-loop neuromodulation therapy, which dynamically adjusts the electrical stimulation parameters based on real-time feedback from the recorded neural activity because they can cause saturation or prolonged recovery times in traditional recording front ends. This article presents a per-pixel second-order$\Delta \Sigma $ analog-to-digital converter (ADC) for direct digitization of neural signals, which addresses the stimulation artifact recovery time in voltage-controlled oscillator (VCO)-based quantizers with a fast-recovery, overrange-detecting phase quantizer. The ADC uses a pseudo-virtual ground feedforwarding (PVG FF) technique and a complementary input${G} _{\text {m}}$ -C filter with per-pixel decimation. It supports four recording modes covering 2.5–20 kS/s through a power-efficient, bandwidth-scalable continuous time$\Delta \Sigma $ modulator. Fabricated in a 180-nm CMOS process, this$300\times 300~\mu $ m2 ADC achieves$\gt 250\times $ faster (0.05–0.4 ms) stimulation artifact recovery time, enabling in-stimulation recording. Recording with artifact tolerance was demonstrated through an in vivo whisker barrel rat experiment.- 18 December 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Solid-State Circuits
- Vol. 60 (3) , 894-907
A 2.5–20 kS/s In-Pixel Direct Digitization ECoG Front End With Submillisecond Stimulation Artifact Recovery
Neural stimulation is used routinely to diagnose and treat neurological disorders. The stimulation artifacts are, however, problematic for closed-loop neuromodulation therapy, which dynamically adjusts the electrical stimulation parameters based on real-time feedback from the recorded neural activity because they can cause saturation or prolonged recovery times in traditional recording front ends. This article presents a per-pixel second-order$\Delta \Sigma $ analog-to-digital converter (ADC) for direct digitization of neural signals, which addresses the stimulation artifact recovery time in voltage-controlled oscillator (VCO)-based quantizers with a fast-recovery, overrange-detecting phase quantizer. The ADC uses a pseudo-virtual ground feedforwarding (PVG FF) technique and a complementary input${G} _{\text {m}}$ -C filter with per-pixel decimation. It supports four recording modes covering 2.5–20 kS/s through a power-efficient, bandwidth-scalable continuous time$\Delta \Sigma $ modulator. Fabricated in a 180-nm CMOS process, this$300\times 300~\mu $ m2 ADC achieves$\gt 250\times $ faster (0.05–0.4 ms) stimulation artifact recovery time, enabling in-stimulation recording. Recording with artifact tolerance was demonstrated through an in vivo whisker barrel rat experiment.- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (2) , 416-427
An Electrochemical CMOS Biosensor Array Using Phase-Only Modulation With 0.035% Phase Error and In-Pixel Averaging
This paper presents a 16×20 CMOS biosensor array based on electrochemical impedance spectroscopy (EIS), a highly sensitive label-free technique for rapid disease detection at point-of-care. This high-density system implements a polar-mode detection with phase-only EIS measurement over a 5 kHz - 1 MHz frequency range. The design features predominantly digital readout circuitry, ensuring scalability with technology, along with a load-compensated transimpedance amplifier at the front, all within a 140×140 μm 2 ; pixel. The architecture enables in-pixel digitization and accumulation, which increases the SNR by 10 dB for each 10× increase in readout time. Implemented in a 180 nm CMOS process, the 3×4 mm 2 chip achieves state-of-the-art performance with an rms phase error of 0.035% at 100 kHz through a duty-cycle insensitive phase detector and one of the smallest per pixel areas with in-pixel quantization.
- 28 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Circuits and Systems
- Vol. 19 (2) , 416-427
An Electrochemical CMOS Biosensor Array Using Phase-Only Modulation With 0.035% Phase Error and In-Pixel Averaging
This paper presents a 16×20 CMOS biosensor array based on electrochemical impedance spectroscopy (EIS), a highly sensitive label-free technique for rapid disease detection at point-of-care. This high-density system implements a polar-mode detection with phase-only EIS measurement over a 5 kHz - 1 MHz frequency range. The design features predominantly digital readout circuitry, ensuring scalability with technology, along with a load-compensated transimpedance amplifier at the front, all within a 140×140 μm 2 ; pixel. The architecture enables in-pixel digitization and accumulation, which increases the SNR by 10 dB for each 10× increase in readout time. Implemented in a 180 nm CMOS process, the 3×4 mm 2 chip achieves state-of-the-art performance with an rms phase error of 0.035% at 100 kHz through a duty-cycle insensitive phase detector and one of the smallest per pixel areas with in-pixel quantization.
- 20 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 704-708
A 310 nW Temperature Sensor Achieving 9.8 mK Resolution Using a DFLL-Based Readout Circuit
This brief reports a high-performance, low-power temperature sensor suitable for wireless IoT devices/RFID tags. The system utilizes a mostly digital approach to achieve energy-efficient, sub- $\mu \text{W}$ operation with a resistor-based temperature sensor. A sampled, incomplete-settling, switched-capacitor-based Wheatstone bridge is read out using a digital frequency-locked loop (DFLL) while harnessing the quasi-periodic limit cycles to reduce in-band noise. Implemented in a 65 nm CMOS process, it consumes 310 nW and achieves 9.8 mK resolution in a 10 ms conversion time. This results in a 297 fJ ${\mathrm {\cdot }}\text{K}~^{2}$ figure-of-merit (FoM) and low energy (3.1 nJ/meas.).
- 20 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems II: Express Briefs
- Vol. 69 (3) , 704-708
A 310 nW Temperature Sensor Achieving 9.8 mK Resolution Using a DFLL-Based Readout Circuit
This brief reports a high-performance, low-power temperature sensor suitable for wireless IoT devices/RFID tags. The system utilizes a mostly digital approach to achieve energy-efficient, sub- $\mu \text{W}$ operation with a resistor-based temperature sensor. A sampled, incomplete-settling, switched-capacitor-based Wheatstone bridge is read out using a digital frequency-locked loop (DFLL) while harnessing the quasi-periodic limit cycles to reduce in-band noise. Implemented in a 65 nm CMOS process, it consumes 310 nW and achieves 9.8 mK resolution in a 10 ms conversion time. This results in a 297 fJ ${\mathrm {\cdot }}\text{K}~^{2}$ figure-of-merit (FoM) and low energy (3.1 nJ/meas.).
- Open Access
- 3 February 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (7) , 1352-1363
Practical microcircuits for handheld acoustofluidics
Practical acoustofluidics for lab-on-a-chip applications is now enabled by battery-powered handheld circuits.
- 3 February 2021
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 21 (7) , 1352-1363
Open AccessPractical microcircuits for handheld acoustofluidics
Practical acoustofluidics for lab-on-a-chip applications is now enabled by battery-powered handheld circuits.