Wentong Yi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wentong Yi has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Wenzhong Liu
Huazhong University of Science and Technology
5 shared publications Tao Jiang
School of Artificial Intelligence and Automation, Huazhong University of Science and Technology, Wuhan 430074, People’s Republic of China
2 shared publicationsZhongzhou Du
School of Computer and Communication Engineering, Zhengzhou University of Light Industry, Zhengzhou 450001, People’s Republic of China
2 shared publications- Zhongzhou Du
School of Computer Science and Technology, ZhengZhou University of Light Industry, ZhengZhou, China
2 shared publications De Hou
Anhui Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, HFIPS, Anhui, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
1 shared publicationGuoqiang Ning
Anhui Key Laboratory of Condensed Matter Physics at Extreme Conditions, High Magnetic Field Laboratory, HFIPS, Anhui, Chinese Academy of Sciences, Hefei 230031, People’s Republic of China
1 shared publication
Latest Publications
- 29 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075112
Remote measurement of transient heat flux based on the thermomagnetic effect
Heat flux is a physical quantity that characterises the strength of heat transfer per unit area. Heat transfer occurs with a temperature difference. Herein, a remote heat flux measurement method based on the thermomagnetic effect is proposed. Using Bloch’s law, Faraday’s law of electromagnetic induction, and Fourier’s law, a temperature measurement model from heat flux to magnetisation of the magnetic film and finally to the induced electromotive force in the Helmholtz coil is established. A compression corner was fabricated, and the heat flux measurement method was experimentally verified in a Mach 6 shock tube wind tunnel. In addition, a Schlieren experiment was performed for comparison. In the experiments, the temperature resolution of the magnetic film reached 0.36 K, and the temperature response reached 100 kHz. The range of the proposed heat flux measurement method is up to 5 MW m m − 2 , and the measurement error is less than 10%. At a resolution of 10 μs, the change in heat flow is mapped when there is a transition for the magnetic film from flat to turbulent flow, which shows the different effects of hypersonic heat flux on the boundary layer and attachment position. The magnetic thin film shows the potential for heat flux estimation in our experiment.
- 29 April 2024
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 35 (7) , 075112
Remote measurement of transient heat flux based on the thermomagnetic effect
Heat flux is a physical quantity that characterises the strength of heat transfer per unit area. Heat transfer occurs with a temperature difference. Herein, a remote heat flux measurement method based on the thermomagnetic effect is proposed. Using Bloch’s law, Faraday’s law of electromagnetic induction, and Fourier’s law, a temperature measurement model from heat flux to magnetisation of the magnetic film and finally to the induced electromotive force in the Helmholtz coil is established. A compression corner was fabricated, and the heat flux measurement method was experimentally verified in a Mach 6 shock tube wind tunnel. In addition, a Schlieren experiment was performed for comparison. In the experiments, the temperature resolution of the magnetic film reached 0.36 K, and the temperature response reached 100 kHz. The range of the proposed heat flux measurement method is up to 5 MW m m − 2 , and the measurement error is less than 10%. At a resolution of 10 μs, the change in heat flow is mapped when there is a transition for the magnetic film from flat to turbulent flow, which shows the different effects of hypersonic heat flux on the boundary layer and attachment position. The magnetic thin film shows the potential for heat flux estimation in our experiment.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Rapid and High Sensitivity Temperature Measurement Based on Near-Extinction Photoelastic Modulated Magneto-Optical Kerr Effect of Fe-Gd Nanofilm
In this study, we demonstrate a novel magneto-optical thermometer using a Magneto-optical Kerr Effect (MOKE) system optimally configured with a photoelastic modulator (PEM) that combines the optical and pyro effects of Fe-Gd nanofilm to detect transient surface temperatures with high sensitivity and temporal resolution. The AC-DC harmonic ratio of the modulating frequency senses the temperature-induced Kerr signal of the metal film. In previous MOKE systems using a PEM, the optical axis of the analyzer was configured at 45° to maximize the harmonic amplitude. However, the decreased sensitivity of the harmonic ratio in this conventional configuration leads to lower signal-to-noise ratios (SNRs). By configuring the analyzer axis at a near-extinction position close to 0°, the signal gain of the harmonic ratio can be increased, thus significantly improving the SNRs of the temperature measurement. Experimental results based on near-extinction photoelastic modulated MOKE (NEPEM MOKE) of Fe-Gd nanofilm show that the harmonic ratio achieves a resolution better than 0.02 K over a wide range, from room temperature to the Curie temperature of Fe-Gd nanofilm. On this basis, the magneto-optical thermometer can capture thermal pulses with a pulse width of no less than 80 μs. The proposed method combines the high spatial and temporal resolution of the MOKE, which converts temperature changes into magneto-optical signal changes. Therefore, this noninvasive magneto-optical thermometer provides a possible method for temperature measurements on the micro- and nanometer scales.
- 9 October 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-8
Rapid and High Sensitivity Temperature Measurement Based on Near-Extinction Photoelastic Modulated Magneto-Optical Kerr Effect of Fe-Gd Nanofilm
In this study, we demonstrate a novel magneto-optical thermometer using a Magneto-optical Kerr Effect (MOKE) system optimally configured with a photoelastic modulator (PEM) that combines the optical and pyro effects of Fe-Gd nanofilm to detect transient surface temperatures with high sensitivity and temporal resolution. The AC-DC harmonic ratio of the modulating frequency senses the temperature-induced Kerr signal of the metal film. In previous MOKE systems using a PEM, the optical axis of the analyzer was configured at 45° to maximize the harmonic amplitude. However, the decreased sensitivity of the harmonic ratio in this conventional configuration leads to lower signal-to-noise ratios (SNRs). By configuring the analyzer axis at a near-extinction position close to 0°, the signal gain of the harmonic ratio can be increased, thus significantly improving the SNRs of the temperature measurement. Experimental results based on near-extinction photoelastic modulated MOKE (NEPEM MOKE) of Fe-Gd nanofilm show that the harmonic ratio achieves a resolution better than 0.02 K over a wide range, from room temperature to the Curie temperature of Fe-Gd nanofilm. On this basis, the magneto-optical thermometer can capture thermal pulses with a pulse width of no less than 80 μs. The proposed method combines the high spatial and temporal resolution of the MOKE, which converts temperature changes into magneto-optical signal changes. Therefore, this noninvasive magneto-optical thermometer provides a possible method for temperature measurements on the micro- and nanometer scales.
- 11 April 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (7) , 079601
Erratum: An improved point spread function for complex susceptibility-based magnetic particle imaging (2022 Meas. Sci. Technol. 33 095402)
- 11 April 2023
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 34 (7) , 079601
Erratum: An improved point spread function for complex susceptibility-based magnetic particle imaging (2022 Meas. Sci. Technol. 33 095402)
- 6 June 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (9) , 095402
An improved point spread function for complex susceptibility-based magnetic particle imaging
Spatial resolution is a key metric for characterizing magnetic particle imaging (MPI), and magnetic relaxation is a critical factor affecting the spatial resolution. This study investigates the point spread functions (PSFs) of MPI and analyzes the potential of breaking through the spatial resolution limit, which equals the full width at half maximum (FWHM) of the Langevin function derivative. In this work, different PSFs of MPI were built based on the magnitude and real and imaginary parts of complex susceptibility. The imaging performance was evaluated using the FWHM and a self-defined convergence parameter. The results show that image reconstruction can achieve a narrower PSF based on the imaginary part of complex susceptibility, and the heavy-tailed distribution of the derivative of the Langevin curve can be optimized. This suggests that there is scope to improve the spatial resolution and image contrast of MPI.
- 6 June 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (9) , 095402
An improved point spread function for complex susceptibility-based magnetic particle imaging
Spatial resolution is a key metric for characterizing magnetic particle imaging (MPI), and magnetic relaxation is a critical factor affecting the spatial resolution. This study investigates the point spread functions (PSFs) of MPI and analyzes the potential of breaking through the spatial resolution limit, which equals the full width at half maximum (FWHM) of the Langevin function derivative. In this work, different PSFs of MPI were built based on the magnitude and real and imaginary parts of complex susceptibility. The imaging performance was evaluated using the FWHM and a self-defined convergence parameter. The results show that image reconstruction can achieve a narrower PSF based on the imaginary part of complex susceptibility, and the heavy-tailed distribution of the derivative of the Langevin curve can be optimized. This suggests that there is scope to improve the spatial resolution and image contrast of MPI.
- 28 March 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (6) , 065110
Temperature measurement based on the magneto-optic Kerr effect in Ni nanofilms
Thermometry is essential in laboratory and industry settings. We propose a noninvasive temperature measurement method based on the superparamagnetic properties of nickel-plated films. When the nickel (Ni) film is uniformly heated from 100 K to 300 K, we observe that the polarization angle of the reflected polarized light decreases correspondingly. Compared with optical temperature measurement, this method introduces magnetic physical quantity, which increases the penetration of temperature measurement. Compared with magnetic temperature measurement, this method introduces optical physical quantity, which greatly increases the amount of information contained in the measurement channel. On this basis, we introduce the characteristic matrix of membrane system, and the improved the mean field theory which can interpret superparamagnetism. Our experiment has demonstrated that the above theoretical model is feasible from low temperature to normal temperature. The thin film sensor element provides the necessary temperature information for cryogenic wind tunnel design and hypersonic vehicle surface model design in real time
- 28 March 2022
- Published by IOP Publishing in Measurement Science and Technology
- Vol. 33 (6) , 065110
Temperature measurement based on the magneto-optic Kerr effect in Ni nanofilms
Thermometry is essential in laboratory and industry settings. We propose a noninvasive temperature measurement method based on the superparamagnetic properties of nickel-plated films. When the nickel (Ni) film is uniformly heated from 100 K to 300 K, we observe that the polarization angle of the reflected polarized light decreases correspondingly. Compared with optical temperature measurement, this method introduces magnetic physical quantity, which increases the penetration of temperature measurement. Compared with magnetic temperature measurement, this method introduces optical physical quantity, which greatly increases the amount of information contained in the measurement channel. On this basis, we introduce the characteristic matrix of membrane system, and the improved the mean field theory which can interpret superparamagnetism. Our experiment has demonstrated that the above theoretical model is feasible from low temperature to normal temperature. The thin film sensor element provides the necessary temperature information for cryogenic wind tunnel design and hypersonic vehicle surface model design in real time