Emma Margaretha Teunissen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Emma Margaretha Teunissen has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Myrthe Karianne Sophie Hol
Department of Otorhinolaryngology/Head and Neck Surgery, University Medical Center Groningen, Groningen, The Netherlands
5 shared publications - Coosje Jacoba Isabella Caspers
Department of Otorhinolaryngology, Radboud university medical center, Nijmegen, The Netherlands
3 shared publications - Emmanuel Antonius Maria Mylanus
Department of Otorhinolaryngology and Head and Neck Surgery, Radboud University Medical Centre for Brain and Senses, 6525 Nijmegen, The Netherlands
3 shared publications Myrthe K. S. Hol
Department of Otorhinolaryngology, Donders Center for Neurosciences, Radboud University Medical Centre
3 shared publications- Arno M. Janssen
Department of Otorhinolaryngology Donders Center for Neurosciences, Radboud University Medical Center Nijmegen The Netherlands
2 shared publications Kim H. E. Bakkum
Department of Otorhinolaryngology, Donders Center for Neurosciences, Radboud University Medical Centre
2 shared publications
Latest Publications
- Open Access
- 11 September 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Long-Term Clinical Performance of a Wide-Diameter Bone-Anchored Hearing Implant: Over 10 Years of Follow-up
Objective: To investigate long-term survival and stability of a wide-diameter bone-anchored hearing implant, soft tissue reactions, and quality of life at least 10 years after implantation. Study design: This study is a continuation of previously published single-center trials with 6-month, 3-year, and 5-year results, adding one follow-up visit at least 10 years postimplantation. Patients and main outcome measures: A total of 48 patients (49 implants) from 63 participants in previous trials, all of whom received the Ponto Wide implant, were included. Implant survival was evaluated for all 63 patients (65 implants). Most patients attended the outpatient clinic, where implant stability was measured and soft tissue reactions around the abutment were assessed using the Holgers classification and IPS scale. In addition, quality of life was evaluated using the International Outcome Inventory for Hearing Aids (IOI-HA) and the Glasgow Benefit Inventory (GBI) questionnaires. Results: The 10-year implant survival rate was 95.4%, including explantations. At the ≥10-year follow-up visit, ISQ values were higher compared to baseline at surgery, and minor skin reactions were observed in only 3 patients. No adverse skin reactions occurred. Hearing-related quality of life improved in 92.1% of patients (GBI) compared to before the intervention, and the median IOI-HA score was 4.3 (IQR: 3.7-4.6), indicating a high level of satisfaction. Conclusion: The Ponto Wide implant shows excellent long-term outcomes with high implant survival, sustained stability, very low soft tissue complications, and high patient-reported satisfaction. These results confirm that the early advantages of this wide implant persist over time.
- 11 September 2026
- Published by Wolters Kluwer Health in Otology & Neurotology
Open AccessLong-Term Clinical Performance of a Wide-Diameter Bone-Anchored Hearing Implant: Over 10 Years of Follow-up
Objective: To investigate long-term survival and stability of a wide-diameter bone-anchored hearing implant, soft tissue reactions, and quality of life at least 10 years after implantation. Study design: This study is a continuation of previously published single-center trials with 6-month, 3-year, and 5-year results, adding one follow-up visit at least 10 years postimplantation. Patients and main outcome measures: A total of 48 patients (49 implants) from 63 participants in previous trials, all of whom received the Ponto Wide implant, were included. Implant survival was evaluated for all 63 patients (65 implants). Most patients attended the outpatient clinic, where implant stability was measured and soft tissue reactions around the abutment were assessed using the Holgers classification and IPS scale. In addition, quality of life was evaluated using the International Outcome Inventory for Hearing Aids (IOI-HA) and the Glasgow Benefit Inventory (GBI) questionnaires. Results: The 10-year implant survival rate was 95.4%, including explantations. At the ≥10-year follow-up visit, ISQ values were higher compared to baseline at surgery, and minor skin reactions were observed in only 3 patients. No adverse skin reactions occurred. Hearing-related quality of life improved in 92.1% of patients (GBI) compared to before the intervention, and the median IOI-HA score was 4.3 (IQR: 3.7-4.6), indicating a high level of satisfaction. Conclusion: The Ponto Wide implant shows excellent long-term outcomes with high implant survival, sustained stability, very low soft tissue complications, and high patient-reported satisfaction. These results confirm that the early advantages of this wide implant persist over time.
- 8 April 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (6) , 491-498
Single-stage bone-anchored hearing implant surgery in children: a prospective comparative study
- 8 April 2025
- Published by Taylor & Francis in Acta Oto-Laryngologica
- Vol. 145 (6) , 491-498
Single-stage bone-anchored hearing implant surgery in children: a prospective comparative study
- Open Access
- 1 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (2) , 161-169
Long-Term Clinical Outcomes for Bone-Anchored Hearing Implants: 3-Year Comparison Between Minimally Invasive Ponto Surgery and the Linear Incision Technique With Tissue Preservation
Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs). Study design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP. Setting: Tertiary referral center. Patients: In the m-MIPS group, 24 patients with 25 implants were enrolled. The o-MIPS and LIT-TP groups included 25 patients (25 implants) each. Interventions: The patients underwent BAHI surgery using m-MIPS, o-MIPS, or LIT-TP. Main outcome measures: Implant survival and implant stability were compared between all groups. Soft tissue status, skin sensibility, subjective numbness, and hearing-related quality of life (HRQoL) were compared between m-MIPS and LIT-TP and o-MIPS and LIT-TP, respectively. Results: Implant survival was comparable between m-MIPS and LIT-TP (96 versus 100%), with o-MIPS showing nonsignificant lower survival (88%). Both MIPS groups exhibited fewer (adverse) skin reactions, better skin sensibility, and less subjective numbness than LIT-TP throughout visits. At 3 years, soft tissue status, sensibility, and numbness were comparable between groups. Device use was consistent among groups (83–86% daily users). All groups demonstrated significant improvement in HRQoL post-surgery based on GBI, GHSI, and APHAB total scores. Conclusions: Compared with LIT-TP, m-MIPS showed comparable long-term implant survival, fewer (adverse) skin reactions, and earlier sensibility and numbness recovery. M-MIPS resulted in favorable clinical and QoL outcomes with low intra- and postoperative complication rates until 3 years after surgery. It is therefore considered a safe technique for BAHI insertion. Moreover, with a shorter surgery time and the ability to operate under local anesthesia in a controlled outpatient setting, m-MIPS appears to be a more efficient alternative to LIT-TP.
- 1 February 2025
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 46 (2) , 161-169
Open AccessLong-Term Clinical Outcomes for Bone-Anchored Hearing Implants: 3-Year Comparison Between Minimally Invasive Ponto Surgery and the Linear Incision Technique With Tissue Preservation
Objective: To compare the 3-year outcomes of the modified minimally invasive Ponto surgery (m-MIPS) to both the original MIPS (o-MIPS) and linear incision technique with soft tissue preservation (LIT-TP) for inserting bone-anchored hearing implants (BAHIs). Study design: Prospective study with three patient groups: m-MIPS, o-MIPS, and LIT-TP. Setting: Tertiary referral center. Patients: In the m-MIPS group, 24 patients with 25 implants were enrolled. The o-MIPS and LIT-TP groups included 25 patients (25 implants) each. Interventions: The patients underwent BAHI surgery using m-MIPS, o-MIPS, or LIT-TP. Main outcome measures: Implant survival and implant stability were compared between all groups. Soft tissue status, skin sensibility, subjective numbness, and hearing-related quality of life (HRQoL) were compared between m-MIPS and LIT-TP and o-MIPS and LIT-TP, respectively. Results: Implant survival was comparable between m-MIPS and LIT-TP (96 versus 100%), with o-MIPS showing nonsignificant lower survival (88%). Both MIPS groups exhibited fewer (adverse) skin reactions, better skin sensibility, and less subjective numbness than LIT-TP throughout visits. At 3 years, soft tissue status, sensibility, and numbness were comparable between groups. Device use was consistent among groups (83–86% daily users). All groups demonstrated significant improvement in HRQoL post-surgery based on GBI, GHSI, and APHAB total scores. Conclusions: Compared with LIT-TP, m-MIPS showed comparable long-term implant survival, fewer (adverse) skin reactions, and earlier sensibility and numbness recovery. M-MIPS resulted in favorable clinical and QoL outcomes with low intra- and postoperative complication rates until 3 years after surgery. It is therefore considered a safe technique for BAHI insertion. Moreover, with a shorter surgery time and the ability to operate under local anesthesia in a controlled outpatient setting, m-MIPS appears to be a more efficient alternative to LIT-TP.
- Open Access
- 26 August 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (9) , 1037-1044
Evaluation of Clinical Performance of Ponto Implantation Using a Minimally Invasive Surgical Technique—A Prospective Multicenter Study
Objective: To investigate the clinical outcomes of bone-anchored hearing implant surgery using the MONO procedure. Study Design: Multicenter, multinational, single-arm, prospective trial with a 12-month follow-up. Setting: Seven European university hospitals from the United Kingdom, Sweden, Denmark, and The Netherlands. Patients: Fifty-one adult patients requiring surgical intervention for bone conduction hearing. Intervention: Bone-anchored hearing implant surgery using the MONO procedure. Main Outcome Measures: The primary endpoint assessed implant usability 3 months after surgery. Implant status, soft tissue reactions, pain and numbness, postoperative events, and sound processor usage were assessed at all follow-up visits. Hearing-related quality of life was evaluated using the Glasgow Benefit Inventory (GBI). Results: At 3 months, 94.2% of the implant/abutment complexes provided reliable anchorage for sound processor usage. No severe intraoperative complications occurred. Sixty-nine percent of surgeries were performed under local anesthesia, with surgery lasting 10 minutes on average. Four implants were lost due to trauma (n = 2), spontaneous loss of osseointegration (n = 1), or incomplete insertion (n = 1). Adverse soft tissue reactions occurred in 2.6% of visits, with a maximum Holgers grade of 3 (n = 1) and grade 2 (n = 5) across patients. Hearing-related quality of life at 3 months improved in 96% of patients. Conclusion: The MONO procedure provides a safe and efficient surgical technique for inserting bone-anchored hearing implants with few and minor intra- and postoperative complications.
- 26 August 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (9) , 1037-1044
Open AccessEvaluation of Clinical Performance of Ponto Implantation Using a Minimally Invasive Surgical Technique—A Prospective Multicenter Study
Objective: To investigate the clinical outcomes of bone-anchored hearing implant surgery using the MONO procedure. Study Design: Multicenter, multinational, single-arm, prospective trial with a 12-month follow-up. Setting: Seven European university hospitals from the United Kingdom, Sweden, Denmark, and The Netherlands. Patients: Fifty-one adult patients requiring surgical intervention for bone conduction hearing. Intervention: Bone-anchored hearing implant surgery using the MONO procedure. Main Outcome Measures: The primary endpoint assessed implant usability 3 months after surgery. Implant status, soft tissue reactions, pain and numbness, postoperative events, and sound processor usage were assessed at all follow-up visits. Hearing-related quality of life was evaluated using the Glasgow Benefit Inventory (GBI). Results: At 3 months, 94.2% of the implant/abutment complexes provided reliable anchorage for sound processor usage. No severe intraoperative complications occurred. Sixty-nine percent of surgeries were performed under local anesthesia, with surgery lasting 10 minutes on average. Four implants were lost due to trauma (n = 2), spontaneous loss of osseointegration (n = 1), or incomplete insertion (n = 1). Adverse soft tissue reactions occurred in 2.6% of visits, with a maximum Holgers grade of 3 (n = 1) and grade 2 (n = 5) across patients. Hearing-related quality of life at 3 months improved in 96% of patients. Conclusion: The MONO procedure provides a safe and efficient surgical technique for inserting bone-anchored hearing implants with few and minor intra- and postoperative complications.
- Open Access
- 26 June 2024
- Published by Wiley in Clinical Otolaryngology
- Vol. 49 (5) , 670-676
Evaluation of a super powerful bone‐anchored hearing system and its users: A retrospective study
Introduction: Although the Baha 5SP has been commercially available for six years, very few studies have been performed on the device's efficacy. The current study aims to evaluate the characteristics and audiological results in patients with severe‐to‐profound mixed hearing loss fitted with this superpower sound processor.Methods: This retrospective evaluation was conducted at a tertiary referral centre where a series of 82 adult patients with severe‐to‐profound mixed hearing loss were implanted with a percutaneous bone‐anchored hearing system and fitted with a superpower sound processor between 2016 and 2019. Patients with incomplete or unreliable audiological data (n = 24) were excluded, resulting in 58 data sets for analysis. The main outcome measures were unaided and aided pure‐tone thresholds and aided free‐field speech perception in quiet.Results: The median unaided air conduction (AC) threshold averaged across 0.5, 1 and 2 kHz (PTA0.5–2kHz) of all patients was 75 dB hearing loss (HL); the median unaided AC averaged across 1, 2 and 4 kHz (PTA1–4kHz) was 84 dB HL. For bone conduction and direct bone conduction, the median PTA0.5–2kHz was 52 and 47 dB HL, respectively. With the superpower device, the median free‐field speech reception threshold was 54 dB sound pressure level (SPL), and the median speech perception score at 65 dB SPL was 80%.Conclusions: At least 75% of the patients reached a maximum phoneme score of 70%. For patients with lower scores, the superpower device still provides a substantial hearing benefit. This makes the superpower device particularly suitable for patients with severe‐to‐profound mixed hearing loss with a contraindication for conventional hearing aids and/or cochlear implants.
- 26 June 2024
- Published by Wiley in Clinical Otolaryngology
- Vol. 49 (5) , 670-676
Open AccessEvaluation of a super powerful bone‐anchored hearing system and its users: A retrospective study
Introduction: Although the Baha 5SP has been commercially available for six years, very few studies have been performed on the device's efficacy. The current study aims to evaluate the characteristics and audiological results in patients with severe‐to‐profound mixed hearing loss fitted with this superpower sound processor.Methods: This retrospective evaluation was conducted at a tertiary referral centre where a series of 82 adult patients with severe‐to‐profound mixed hearing loss were implanted with a percutaneous bone‐anchored hearing system and fitted with a superpower sound processor between 2016 and 2019. Patients with incomplete or unreliable audiological data (n = 24) were excluded, resulting in 58 data sets for analysis. The main outcome measures were unaided and aided pure‐tone thresholds and aided free‐field speech perception in quiet.Results: The median unaided air conduction (AC) threshold averaged across 0.5, 1 and 2 kHz (PTA0.5–2kHz) of all patients was 75 dB hearing loss (HL); the median unaided AC averaged across 1, 2 and 4 kHz (PTA1–4kHz) was 84 dB HL. For bone conduction and direct bone conduction, the median PTA0.5–2kHz was 52 and 47 dB HL, respectively. With the superpower device, the median free‐field speech reception threshold was 54 dB sound pressure level (SPL), and the median speech perception score at 65 dB SPL was 80%.Conclusions: At least 75% of the patients reached a maximum phoneme score of 70%. For patients with lower scores, the superpower device still provides a substantial hearing benefit. This makes the superpower device particularly suitable for patients with severe‐to‐profound mixed hearing loss with a contraindication for conventional hearing aids and/or cochlear implants.
- Open Access
- 1 June 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (5) , e435-e442
Long-Term Outcomes of a Percutaneous Wide-Diameter Bone-Anchored Hearing Implant: A Clinical Evaluation of More than 800 Implants
Objective: This study evaluates the clinical outcomes of 807 percutaneous wide-diameter bone-anchored hearing implants (BAHIs) in 701 patients. In addition, it compares patient groups and examines bone conduction device (BCD) usage. Study design: Retrospective cohort study. Mean follow-up period of 3.8 years. Setting: Tertiary referral center. Patients: All patients implanted with a percutaneous wide-diameter BAHI until December 2020 were included. Patients were divided into age groups, “loading-time” groups, and, if applicable, specific subgroups thought to be at risk for complications postsurgery, e.g., intellectual disability and comorbidities. Main outcome measures: Soft tissue reaction, implant survival, revision surgery, and BCD usage. Results: In 9.1% of the 5,188 observations of 807 implants, an adverse soft tissue reaction was reported according to the Holgers’ scale. Significantly more (adverse) soft tissue reactions were observed in children and intellectually disabled (ID) patients (p < 0.05). Comorbidity subgroups showed no significant differences in soft tissue reactions. Implant loss percentage, including explantations, was 6.2%. Implant survival was significantly worse in patients with ID (14.1%; p = 0.021). Pediatric age, early loading, or comorbidities did not significantly influence implant survival. At least 592 implants (73.4%) were used for bone conduction hearing, of which 65.4% were used daily. Conclusion: Both children and ID patients are more prone to (adverse) soft tissue reactions, ID patients only have a higher risk of implant loss. The rate of implant loss in children seemed to be reduced compared to previous studies and thus more comparable to adults since using wide-diameter implants.
- 1 June 2024
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 45 (5) , e435-e442
Open AccessLong-Term Outcomes of a Percutaneous Wide-Diameter Bone-Anchored Hearing Implant: A Clinical Evaluation of More than 800 Implants
Objective: This study evaluates the clinical outcomes of 807 percutaneous wide-diameter bone-anchored hearing implants (BAHIs) in 701 patients. In addition, it compares patient groups and examines bone conduction device (BCD) usage. Study design: Retrospective cohort study. Mean follow-up period of 3.8 years. Setting: Tertiary referral center. Patients: All patients implanted with a percutaneous wide-diameter BAHI until December 2020 were included. Patients were divided into age groups, “loading-time” groups, and, if applicable, specific subgroups thought to be at risk for complications postsurgery, e.g., intellectual disability and comorbidities. Main outcome measures: Soft tissue reaction, implant survival, revision surgery, and BCD usage. Results: In 9.1% of the 5,188 observations of 807 implants, an adverse soft tissue reaction was reported according to the Holgers’ scale. Significantly more (adverse) soft tissue reactions were observed in children and intellectually disabled (ID) patients (p < 0.05). Comorbidity subgroups showed no significant differences in soft tissue reactions. Implant loss percentage, including explantations, was 6.2%. Implant survival was significantly worse in patients with ID (14.1%; p = 0.021). Pediatric age, early loading, or comorbidities did not significantly influence implant survival. At least 592 implants (73.4%) were used for bone conduction hearing, of which 65.4% were used daily. Conclusion: Both children and ID patients are more prone to (adverse) soft tissue reactions, ID patients only have a higher risk of implant loss. The rate of implant loss in children seemed to be reduced compared to previous studies and thus more comparable to adults since using wide-diameter implants.
- Open Access
- 8 July 2023
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 281 (1) , 117-127
Post-implantation clinical cost analysis between transcutaneous and percutaneous bone conduction devices
Introduction: Bone conduction devices (BCD) are effective for hearing rehabilitation in patients with conductive and mixed hearing loss or single-sided deafness. Transcutaneous bone conduction devices (tBCD) seem to lead to fewer soft tissue complications than percutaneous BCDs (pBCD) but have other drawbacks such as MRI incompatibility and higher costs. Previous cost analyses have shown a cost advantage of tBCDs. The purpose of this study is to compare long-term post-implantations costs between percutaneous and transcutaneous BCDs. Materials and methods: Retrospective data from 77 patients implanted in a tertiary referral centre with a pBCD (n = 34), tBCD (n = 43; passive (tpasBCD; n = 34) and active (tactBCD; n = 9) and a reference group who underwent cochlear implantation (CI; n = 34), were included in a clinical cost analysis. Post-implantation costs were determined as the sum of consultation (medical and audiological) and additional (all post-operative care) costs. Median (cumulative) costs per device incurred for the different cohorts were compared at 1, 3 and 5 years after implantation. Results: After 5 years, the total post-implantation costs of the pBCD vs tpasBCD were not significantly different (€1550.7 [IQR 1174.6–2797.4] vs €2266.9 [IQR 1314.1–3535.3], p = 0.185), nor was there a significant difference between pBCD vs tactBCD (€1550.7 [1174.6–2797.4] vs €1428.8 [1277.3–1760.4], p = 0.550). Additional post-implantation costs were significantly highest in the tpasBCD cohort at all moments of follow-up. Conclusion: Total costs related to post-operative rehabilitation and treatments are comparable between percutaneous and transcutaneous BCDs up to 5 years after implantation. Complications related to passive transcutaneous bone conduction devices appeared significantly more expensive after implantation due to more frequent explantations.
- 8 July 2023
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 281 (1) , 117-127
Open AccessPost-implantation clinical cost analysis between transcutaneous and percutaneous bone conduction devices
Introduction: Bone conduction devices (BCD) are effective for hearing rehabilitation in patients with conductive and mixed hearing loss or single-sided deafness. Transcutaneous bone conduction devices (tBCD) seem to lead to fewer soft tissue complications than percutaneous BCDs (pBCD) but have other drawbacks such as MRI incompatibility and higher costs. Previous cost analyses have shown a cost advantage of tBCDs. The purpose of this study is to compare long-term post-implantations costs between percutaneous and transcutaneous BCDs. Materials and methods: Retrospective data from 77 patients implanted in a tertiary referral centre with a pBCD (n = 34), tBCD (n = 43; passive (tpasBCD; n = 34) and active (tactBCD; n = 9) and a reference group who underwent cochlear implantation (CI; n = 34), were included in a clinical cost analysis. Post-implantation costs were determined as the sum of consultation (medical and audiological) and additional (all post-operative care) costs. Median (cumulative) costs per device incurred for the different cohorts were compared at 1, 3 and 5 years after implantation. Results: After 5 years, the total post-implantation costs of the pBCD vs tpasBCD were not significantly different (€1550.7 [IQR 1174.6–2797.4] vs €2266.9 [IQR 1314.1–3535.3], p = 0.185), nor was there a significant difference between pBCD vs tactBCD (€1550.7 [1174.6–2797.4] vs €1428.8 [1277.3–1760.4], p = 0.550). Additional post-implantation costs were significantly highest in the tpasBCD cohort at all moments of follow-up. Conclusion: Total costs related to post-operative rehabilitation and treatments are comparable between percutaneous and transcutaneous BCDs up to 5 years after implantation. Complications related to passive transcutaneous bone conduction devices appeared significantly more expensive after implantation due to more frequent explantations.
- Open Access
- 23 November 2022
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (1) , 40-46
Long-Term Follow-up of a Wide-Diameter Bone-Anchored Hearing Implant: 10-Year Experience on Stability, Survival, and Tolerability of an Implant-Abutment Combination
Objective: To compare stability, survival, and soft tissue reactions between a wide-diameter (test) and previous-generation small-diameter (control) bone-anchored hearing implant and to ascertain the safety of loading the test implant 3 weeks after surgery, at a long-term follow-up of 10 years. Study Design: This study is a continuation of two previously completed, multicenter, randomized, controlled trials and consisted of one to two additional follow-up visits until 10 years after surgery. Patients: Fifty-one of the 72 participants from the previous trials were included. Patients received a test or control implant. All control implants were loaded 6 weeks after surgery (group A). Test implants were loaded 3 (group B) or 6 weeks (group C) after surgery. Results: The test implant showed significantly higher implant stability quotient (ISQ) values than the control implant throughout the 10-year follow-up. At 10 years, the mean ISQ-high values for both implants were higher than at the first follow-up visit. No significant differences in change of ISQ-high from baseline to 10 years were noticed between both implants and loading groups. Soft tissue reactions were rarely seen. At 10-year follow-up, no patients presented with adverse soft tissue reactions. Excluding explantations, the implant survival rate was 78.6% (group A), 100% (group B), and 90.0% (group C). Conclusions: The test implant showed superior mean ISQ values and significantly better implant survival throughout 10-year follow-up. In addition, the current study concludes that it is safe to load the test implant at 3 weeks after surgery, as long-term results show high ISQ values and good implant survival.
- 23 November 2022
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 44 (1) , 40-46
Open AccessLong-Term Follow-up of a Wide-Diameter Bone-Anchored Hearing Implant: 10-Year Experience on Stability, Survival, and Tolerability of an Implant-Abutment Combination
Objective: To compare stability, survival, and soft tissue reactions between a wide-diameter (test) and previous-generation small-diameter (control) bone-anchored hearing implant and to ascertain the safety of loading the test implant 3 weeks after surgery, at a long-term follow-up of 10 years. Study Design: This study is a continuation of two previously completed, multicenter, randomized, controlled trials and consisted of one to two additional follow-up visits until 10 years after surgery. Patients: Fifty-one of the 72 participants from the previous trials were included. Patients received a test or control implant. All control implants were loaded 6 weeks after surgery (group A). Test implants were loaded 3 (group B) or 6 weeks (group C) after surgery. Results: The test implant showed significantly higher implant stability quotient (ISQ) values than the control implant throughout the 10-year follow-up. At 10 years, the mean ISQ-high values for both implants were higher than at the first follow-up visit. No significant differences in change of ISQ-high from baseline to 10 years were noticed between both implants and loading groups. Soft tissue reactions were rarely seen. At 10-year follow-up, no patients presented with adverse soft tissue reactions. Excluding explantations, the implant survival rate was 78.6% (group A), 100% (group B), and 90.0% (group C). Conclusions: The test implant showed superior mean ISQ values and significantly better implant survival throughout 10-year follow-up. In addition, the current study concludes that it is safe to load the test implant at 3 weeks after surgery, as long-term results show high ISQ values and good implant survival.
- Open Access
- 11 March 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (1) , 189-198
Subjective Fatigue in Children With Unaided and Aided Unilateral Hearing Loss
Objectives: Fatigue is frequently observed in children with chronic diseases and can affect the quality of life (QoL). However, research in children with unilateral hearing loss (UHL) is scarce. Subsequently, no studies investigated the effects of hearing aids on fatigue in children. This study investigates subjective fatigue and hearing‐related QoL in children with UHL. Furthermore, it evaluates the influence of hearing aids, subject‐specific factors, and respondent‐type on subjective fatigue.Study Design: A cross‐sectional study was conducted from June 2020 until September 2020 at the department of otorhinolaryngology in a tertiary referral center.Methods: The primary outcome was the difference in subjective fatigue and hearing‐related QoL between children with unaided UHL, aided UHL, and normal hearing. Subjective fatigue and hearing‐related QoL were measured using the Pediatric Quality of Life Inventory™ Multidimensional Fatigue Scale (PedsQL™‐MFS) and Hearing Environments and Reflection on Quality of Life (HEAR‐QL™) questionnaires.Results: Along with 36 aided children with UHL, 34 unaided and 36 normal‐hearing children were included. Child reports revealed significantly more cognitive fatigue in children with aided UHL than children with normal hearing (median difference 12.5, P = .013). Parents reported more fatigue in children with UHL compared to normal‐hearing siblings. Especially children with aided UHL seemed at increased risk for fatigue. Children with UHL scored lower on hearing‐related QoL than children with normal hearing. No apparent differences were found in fatigue and QoL between children with unaided and aided UHL.Conclusion: Children with unaided and even aided UHL seem to experience more subjective fatigue and lower hearing‐related QoL than children with normal hearing. Prospective longitudinal studies are required to investigate the influence of hearing aids on fatigue and QoL in individual patients.Level of Evidence: 3 Laryngoscope, 2021 Laryngoscope, 133:189–198, 2023
- 11 March 2022
- Published by Wiley in The Laryngoscope
- Vol. 133 (1) , 189-198
Open AccessSubjective Fatigue in Children With Unaided and Aided Unilateral Hearing Loss
Objectives: Fatigue is frequently observed in children with chronic diseases and can affect the quality of life (QoL). However, research in children with unilateral hearing loss (UHL) is scarce. Subsequently, no studies investigated the effects of hearing aids on fatigue in children. This study investigates subjective fatigue and hearing‐related QoL in children with UHL. Furthermore, it evaluates the influence of hearing aids, subject‐specific factors, and respondent‐type on subjective fatigue.Study Design: A cross‐sectional study was conducted from June 2020 until September 2020 at the department of otorhinolaryngology in a tertiary referral center.Methods: The primary outcome was the difference in subjective fatigue and hearing‐related QoL between children with unaided UHL, aided UHL, and normal hearing. Subjective fatigue and hearing‐related QoL were measured using the Pediatric Quality of Life Inventory™ Multidimensional Fatigue Scale (PedsQL™‐MFS) and Hearing Environments and Reflection on Quality of Life (HEAR‐QL™) questionnaires.Results: Along with 36 aided children with UHL, 34 unaided and 36 normal‐hearing children were included. Child reports revealed significantly more cognitive fatigue in children with aided UHL than children with normal hearing (median difference 12.5, P = .013). Parents reported more fatigue in children with UHL compared to normal‐hearing siblings. Especially children with aided UHL seemed at increased risk for fatigue. Children with UHL scored lower on hearing‐related QoL than children with normal hearing. No apparent differences were found in fatigue and QoL between children with unaided and aided UHL.Conclusion: Children with unaided and even aided UHL seem to experience more subjective fatigue and lower hearing‐related QoL than children with normal hearing. Prospective longitudinal studies are required to investigate the influence of hearing aids on fatigue and QoL in individual patients.Level of Evidence: 3 Laryngoscope, 2021 Laryngoscope, 133:189–198, 2023