Long-Term Clinical Performance of a Wide-Diameter Bone-Anchored Hearing Implant: Over 10 Years of Follow-up
Open Access
- 11 September 2026
- journal article
- research article
- Published by Wolters Kluwer Health in Otology & Neurotology
Abstract
Objective: To investigate long-term survival and stability of a wide-diameter bone-anchored hearing implant, soft tissue reactions, and quality of life at least 10 years after implantation. Study design: This study is a continuation of previously published single-center trials with 6-month, 3-year, and 5-year results, adding one follow-up visit at least 10 years postimplantation. Patients and main outcome measures: A total of 48 patients (49 implants) from 63 participants in previous trials, all of whom received the Ponto Wide implant, were included. Implant survival was evaluated for all 63 patients (65 implants). Most patients attended the outpatient clinic, where implant stability was measured and soft tissue reactions around the abutment were assessed using the Holgers classification and IPS scale. In addition, quality of life was evaluated using the International Outcome Inventory for Hearing Aids (IOI-HA) and the Glasgow Benefit Inventory (GBI) questionnaires. Results: The 10-year implant survival rate was 95.4%, including explantations. At the ≥10-year follow-up visit, ISQ values were higher compared to baseline at surgery, and minor skin reactions were observed in only 3 patients. No adverse skin reactions occurred. Hearing-related quality of life improved in 92.1% of patients (GBI) compared to before the intervention, and the median IOI-HA score was 4.3 (IQR: 3.7-4.6), indicating a high level of satisfaction. Conclusion: The Ponto Wide implant shows excellent long-term outcomes with high implant survival, sustained stability, very low soft tissue complications, and high patient-reported satisfaction. These results confirm that the early advantages of this wide implant persist over time.Keywords
This publication has 39 references indexed in Scilit:
- Clinical and surgical safety in patients transitioning from percutaneous to transcutaneous active bone conduction implantsEuropean Archives of Oto-Rhino-Laryngology, 2025
- Wide diameter bone-anchored hearing system implants: a comparison of long-term follow-up data between tissue reduction and tissue preservation techniquesEuropean Archives of Oto-Rhino-Laryngology, 2018
- Bone anchored hearing implants without skin thinning: the Gruppo Otologico surgical and audiological experienceEuropean Archives of Oto-Rhino-Laryngology, 2016
- Three-week loading of the 4.5 mm wide titanium implant in bone anchored hearing systemsAmerican Journal of Otolaryngology, 2016
- Loading of osseointegrated implants for bone conduction hearing at 3 weeks: 3-year stability, survival, and tolerabilityEuropean Archives of Oto-Rhino-Laryngology, 2015
- Stability, survival, and tolerability of a 4.5-mm-wide bone-anchored hearing implant: 6-month data from a randomized controlled clinical trialEuropean Archives of Oto-Rhino-Laryngology, 2015
- Three week loading for the Baha BI-300® implant systemAmerican Journal of Otolaryngology, 2015
- A systematic review on skin complications of bone-anchored hearing aids in relation to surgical techniquesEuropean Archives of Oto-Rhino-Laryngology, 2014
- World Medical Association Declaration of HelsinkiJAMA, 2013
- Effect of implant size and shape on implant success rates: A literature reviewThe Journal of Prosthetic Dentistry, 2005