Kiyotoshi Oishi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kiyotoshi Oishi has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Hirokuni Arai
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University, Tokyo, Japan
5 shared publications Keiji Oi
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University , Tokyo, Japan
5 shared publications- Tomohiro Mizuno
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University , Tokyo, Japan
5 shared publications - Tatsuki Fujiwara
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University , Tokyo, Japan
4 shared publications - Eiki Nagaoka
Department of Cardiovascular Surgery Institute of Science Tokyo Tokyo Japan
3 shared publications Masafumi Yashima
Department of Cardiovascular Surgery, Graduate School of Medical and Dental Science, Tokyo Medical and Dental University , Tokyo, Japan
2 shared publications
Latest Publications
- 10 September 2026
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- p. 1-4
A punch-assisted unroofing technique for anomalous aortic origin of coronary arteries
We describe a punch-assisted unroofing technique for anomalous aortic origin of coronary arteries (AAOCA) with an intramural course. Conventional unroofing can be technically demanding because the extent of resection must balance adequate relief of stenosis against the risk of aortic wall or valvular injury. A 4-mm aortic punch, selected based on the long-axis diameter of the slit-like coronary orifice, was used to create stepwise, controlled resection of the common wall between the aorta and the intramural coronary artery. The punch provided a predefined resection width and facilitated enlargement of the neo-ostium. Four overlapping punch applications achieved approximately 4–5 mm of unroofing, and the resection margin was reinforced with continuous 7-0 monofilament sutures. Postoperative computed tomography confirmed enlargement of the coronary orifice and resolution of stenosis. This technique provides a simple and reproducible method for unroofing that may reduce operator-dependent variability and facilitate standardized surgical management in selected patients with AAOCA.
- 10 September 2026
- Published by Springer Nature in General Thoracic and Cardiovascular Surgery
- p. 1-4
A punch-assisted unroofing technique for anomalous aortic origin of coronary arteries
We describe a punch-assisted unroofing technique for anomalous aortic origin of coronary arteries (AAOCA) with an intramural course. Conventional unroofing can be technically demanding because the extent of resection must balance adequate relief of stenosis against the risk of aortic wall or valvular injury. A 4-mm aortic punch, selected based on the long-axis diameter of the slit-like coronary orifice, was used to create stepwise, controlled resection of the common wall between the aorta and the intramural coronary artery. The punch provided a predefined resection width and facilitated enlargement of the neo-ostium. Four overlapping punch applications achieved approximately 4–5 mm of unroofing, and the resection margin was reinforced with continuous 7-0 monofilament sutures. Postoperative computed tomography confirmed enlargement of the coronary orifice and resolution of stenosis. This technique provides a simple and reproducible method for unroofing that may reduce operator-dependent variability and facilitate standardized surgical management in selected patients with AAOCA.
- 23 March 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 63 (6)
Ring annuloplasty, optionally combined with edge-to-edge leaflet plications, should be amended with subvalvular repair techniques to efficaciously treat tricuspid regurgitation with severe tethering
This study aimed to evaluate the outcomes of tricuspid annuloplasty with/without additional edge-to-edge plications in patients with functional tricuspid regurgitation and to clarify the impact of tethering on surgical outcomes. This retrospective observational study included patients with moderate or greater functional tricuspid regurgitation who underwent initial tricuspid valve repair between January 2008 and December 2021. The patients were divided into two groups based on whether they had tethering (preoperative tethering area ≥0.75 cm2). All patients underwent annuloplasty, and edge-to-edge plications were added at the regurgitant leakage site identified by saline tests. The surgical outcomes of each group, and the effect of tethering on recurrent moderate or greater tricuspid regurgitation were evaluated. One-hundred and thirty-three patients were included in this study. During the follow-up period of 55.3 (standard deviation: 44.9) months, the 5-year survival rates were 78.4% in patients without tethering and 76.1% in patients with tethering (P = 0.78). The 5-year cumulative incidence rates of readmission for heart failure and recurrent tricuspid regurgitation were 10.8% and 1.3% in patients without tethering and 23.0% and 29.5% in patients with tethering, respectively (P = 0.12 and <0.001). Multivariable analyses revealed that the preoperative and predischarge tethering areas predicted recurrent tricuspid regurgitation. A large tethering area remained postoperatively in patients with tethering. In patients without tethering, annuloplasty and additional edge-to-edge plications are effective in avoiding recurrent tricuspid regurgitation with satisfactory midterm clinical outcomes. However, in patients with tethering, these procedures resulted in residual tethering, which could be leading to recurrent tricuspid regurgitation.
- 23 March 2023
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 63 (6)
Ring annuloplasty, optionally combined with edge-to-edge leaflet plications, should be amended with subvalvular repair techniques to efficaciously treat tricuspid regurgitation with severe tethering
This study aimed to evaluate the outcomes of tricuspid annuloplasty with/without additional edge-to-edge plications in patients with functional tricuspid regurgitation and to clarify the impact of tethering on surgical outcomes. This retrospective observational study included patients with moderate or greater functional tricuspid regurgitation who underwent initial tricuspid valve repair between January 2008 and December 2021. The patients were divided into two groups based on whether they had tethering (preoperative tethering area ≥0.75 cm2). All patients underwent annuloplasty, and edge-to-edge plications were added at the regurgitant leakage site identified by saline tests. The surgical outcomes of each group, and the effect of tethering on recurrent moderate or greater tricuspid regurgitation were evaluated. One-hundred and thirty-three patients were included in this study. During the follow-up period of 55.3 (standard deviation: 44.9) months, the 5-year survival rates were 78.4% in patients without tethering and 76.1% in patients with tethering (P = 0.78). The 5-year cumulative incidence rates of readmission for heart failure and recurrent tricuspid regurgitation were 10.8% and 1.3% in patients without tethering and 23.0% and 29.5% in patients with tethering, respectively (P = 0.12 and <0.001). Multivariable analyses revealed that the preoperative and predischarge tethering areas predicted recurrent tricuspid regurgitation. A large tethering area remained postoperatively in patients with tethering. In patients without tethering, annuloplasty and additional edge-to-edge plications are effective in avoiding recurrent tricuspid regurgitation with satisfactory midterm clinical outcomes. However, in patients with tethering, these procedures resulted in residual tethering, which could be leading to recurrent tricuspid regurgitation.
- Open Access
- 21 September 2022
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 35 (6)
Long-term outcomes of papillary muscle relocation anteriorly for functional mitral regurgitation
This study aimed to evaluate the outcomes of the patients who underwent restrictive annuloplasty (RA) plus papillary muscle relocation anteriorly (PMR-A) with the risk factors in mitral valve repair for functional mitral regurgitation (FMR). Eighty-six patients underwent mitral valve repair with RA for FMR. Thirty-five of them received additional bilateral papillary muscle relocation for severe leaflet tethering. The papillary muscles were relocated posteriorly (PMR-P) early in the study. Then, in the later period, the technique was modified to PMR-A, in which the papillary muscles were relocated anteriorly for 24 cases. The survival of the patients undergoing RA + PMR-A was examined retrospectively, adjusting for differences in patient background. Twenty-three deaths were observed during the follow-up period out of the 86 cases. Independent preoperative risk factors for survival were left ventricular ejection fraction, patient age and B-type natriuretic peptide (BNP) level. Among the patients with BNP P = 0.011), while the hazard ratio of RA alone to RA + PMR-A was not significantly different. Furthermore, reverse remodelling of the left ventricle was observed for 3 years only in RA + PMR-A. Long-term survival for patients who underwent RA plus bilateral PMR-A was promising. Patients with significantly higher BNP had lower survival after valve repair for FMR.
- 21 September 2022
- Published by Oxford University Press (OUP) in Interactive CardioVascular and Thoracic Surgery
- Vol. 35 (6)
Open AccessLong-term outcomes of papillary muscle relocation anteriorly for functional mitral regurgitation
This study aimed to evaluate the outcomes of the patients who underwent restrictive annuloplasty (RA) plus papillary muscle relocation anteriorly (PMR-A) with the risk factors in mitral valve repair for functional mitral regurgitation (FMR). Eighty-six patients underwent mitral valve repair with RA for FMR. Thirty-five of them received additional bilateral papillary muscle relocation for severe leaflet tethering. The papillary muscles were relocated posteriorly (PMR-P) early in the study. Then, in the later period, the technique was modified to PMR-A, in which the papillary muscles were relocated anteriorly for 24 cases. The survival of the patients undergoing RA + PMR-A was examined retrospectively, adjusting for differences in patient background. Twenty-three deaths were observed during the follow-up period out of the 86 cases. Independent preoperative risk factors for survival were left ventricular ejection fraction, patient age and B-type natriuretic peptide (BNP) level. Among the patients with BNP P = 0.011), while the hazard ratio of RA alone to RA + PMR-A was not significantly different. Furthermore, reverse remodelling of the left ventricle was observed for 3 years only in RA + PMR-A. Long-term survival for patients who underwent RA plus bilateral PMR-A was promising. Patients with significantly higher BNP had lower survival after valve repair for FMR.
- 16 March 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (3)
The rotational position of the aortic valve: implications for valve-sparing aortic root replacement
OBJECTIVES: There are few reports on the rotational position of the aortic valve relative to the base of the left ventricle, and its influence on valve-sparing aortic root replacement (VSRR) has not been reported. Based on our experience with complications such as right atrial perforation and tricuspid valve injury, we investigated the cause of these complications in terms of morphological variations in the aortic root and its surrounding structures. METHODS: The aortic valve rotation relative to the base of the left ventricle was assessed in 30 patients with tri-leaflet aortic valves who underwent VSRR. The influence of such anatomical variations on surgical procedures was investigated. RESULTS: The aortic valve was positioned normally in 25 patients (83.3%), rotated counterclockwise in 4 (13.3%), and rotated clockwise in 1 patient (3.3%). In patients with a counterclockwise rotated aortic valve, the non-coronary sinus was the largest compared with other sinuses. This aortic valve rotation could be diagnosed by multidetector row computed tomography. In all patients who had difficulty in the external dissection of the right sinus of Valsalva, the aortic valve was counterclockwise rotated and forcible dissection had a risk of right atrial perforation and tricuspid valve injury. CONCLUSIONS: Aortic valve rotation is an element that complicates VSRR. The rotational position of the aortic valve can be diagnosed preoperatively using multidetector row computed tomography and understanding the anatomy of the aortic valve related to rotational position help decide proper surgical decision-making in performing aortic root reconstruction procedure.
- 16 March 2022
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 62 (3)
The rotational position of the aortic valve: implications for valve-sparing aortic root replacement
OBJECTIVES: There are few reports on the rotational position of the aortic valve relative to the base of the left ventricle, and its influence on valve-sparing aortic root replacement (VSRR) has not been reported. Based on our experience with complications such as right atrial perforation and tricuspid valve injury, we investigated the cause of these complications in terms of morphological variations in the aortic root and its surrounding structures. METHODS: The aortic valve rotation relative to the base of the left ventricle was assessed in 30 patients with tri-leaflet aortic valves who underwent VSRR. The influence of such anatomical variations on surgical procedures was investigated. RESULTS: The aortic valve was positioned normally in 25 patients (83.3%), rotated counterclockwise in 4 (13.3%), and rotated clockwise in 1 patient (3.3%). In patients with a counterclockwise rotated aortic valve, the non-coronary sinus was the largest compared with other sinuses. This aortic valve rotation could be diagnosed by multidetector row computed tomography. In all patients who had difficulty in the external dissection of the right sinus of Valsalva, the aortic valve was counterclockwise rotated and forcible dissection had a risk of right atrial perforation and tricuspid valve injury. CONCLUSIONS: Aortic valve rotation is an element that complicates VSRR. The rotational position of the aortic valve can be diagnosed preoperatively using multidetector row computed tomography and understanding the anatomy of the aortic valve related to rotational position help decide proper surgical decision-making in performing aortic root reconstruction procedure.
- Open Access
- 1 September 2020
- Published by Elsevier in JTCVS Techniques
- Vol. 3, 176-178
Coronary ostial plasty using femoral artery patch in Takayasu aortitis: A 15-year follow-up study
- 1 September 2020
- Published by Elsevier in JTCVS Techniques
- Vol. 3, 176-178
Open AccessCoronary ostial plasty using femoral artery patch in Takayasu aortitis: A 15-year follow-up study
- Open Access
- 1 December 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (6) , e369-e371
Safe and Effective Ultrasound-guided Myectomy and Mitral Valve Repair for HCM
- 1 December 2019
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 108 (6) , e369-e371
Open AccessSafe and Effective Ultrasound-guided Myectomy and Mitral Valve Repair for HCM
- 26 October 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (3) , 233-241
Minimally Circulatory-Assisted On-Pump Beating Coronary Artery Bypass Grafting for Patients With Complex Conditions for Off-Pump Surgery
Off‐pump coronary artery bypass grafting (OPCAB) in patients with acute myocardial infarction (AMI) is difficult because of circulatory deterioration during displacement of the heart. At our institution, we performed minimally circulatory‐assisted on‐pump beating coronary artery bypass grafting (MICAB) in these patients. During MICAB, support flow was controlled at a minimal level to maintain a systemic blood pressure of approximately 100 mm Hg and a pulmonary arterial systolic pressure of 2, 1.32 ± 0.53 L/min/m2, and 1.15 ± 0.47 L/min/m2, respectively, in the emergent and urgent patients following AMI, and 0.44 ± 0.39 L/min/m2, 1.25 ± 0.39 L/min/m2, and 1.14 ± 0.43 L/min/m2, respectively, in the elective patients with either dilated LVs or small target vessels. The lowest mixed venous oxygen saturation during pump support in the MICAB group was significantly higher than that in the OPCAB group (83.8 ± 10.8%, 71.6 ± 7.5%, P < 0.001). Comparing MICAB and OPCAB, the median number of distal bypass grafts for both groups was 4 (25th, 75th percentile: 3, 4) (P = 0.558); the complete revascularization rates were 94.6 and 97.3%, respectively (not significant [NS]); the acute patency rates were 98.9 and 99.2%, respectively (NS); and the 30‐day mortality rates were 2.7 and 0%, respectively (NS). No instances of either cerebrovascular complications or newly occurring postoperative renal failure were noted in either group. There were no statistically significant differences between the groups with respect to early and mid‐term results (freedom from all‐cause death: 82.9 vs. 86.5%, respectively, and freedom from cardiac events at 3 years: 96.4 vs. 96.4%, respectively). MICAB is a safe alternative to OPCAB, particularly in patients with AMI and dilated LV. MICAB is associated with high rates of complete revascularization and acute graft patency, adequate preservation of end‐organ function, and early and mid‐term results comparable with those observed following OPCAB.
- 26 October 2016
- Published by Wiley in Artificial Organs
- Vol. 41 (3) , 233-241
Minimally Circulatory-Assisted On-Pump Beating Coronary Artery Bypass Grafting for Patients With Complex Conditions for Off-Pump Surgery
Off‐pump coronary artery bypass grafting (OPCAB) in patients with acute myocardial infarction (AMI) is difficult because of circulatory deterioration during displacement of the heart. At our institution, we performed minimally circulatory‐assisted on‐pump beating coronary artery bypass grafting (MICAB) in these patients. During MICAB, support flow was controlled at a minimal level to maintain a systemic blood pressure of approximately 100 mm Hg and a pulmonary arterial systolic pressure of 2, 1.32 ± 0.53 L/min/m2, and 1.15 ± 0.47 L/min/m2, respectively, in the emergent and urgent patients following AMI, and 0.44 ± 0.39 L/min/m2, 1.25 ± 0.39 L/min/m2, and 1.14 ± 0.43 L/min/m2, respectively, in the elective patients with either dilated LVs or small target vessels. The lowest mixed venous oxygen saturation during pump support in the MICAB group was significantly higher than that in the OPCAB group (83.8 ± 10.8%, 71.6 ± 7.5%, P < 0.001). Comparing MICAB and OPCAB, the median number of distal bypass grafts for both groups was 4 (25th, 75th percentile: 3, 4) (P = 0.558); the complete revascularization rates were 94.6 and 97.3%, respectively (not significant [NS]); the acute patency rates were 98.9 and 99.2%, respectively (NS); and the 30‐day mortality rates were 2.7 and 0%, respectively (NS). No instances of either cerebrovascular complications or newly occurring postoperative renal failure were noted in either group. There were no statistically significant differences between the groups with respect to early and mid‐term results (freedom from all‐cause death: 82.9 vs. 86.5%, respectively, and freedom from cardiac events at 3 years: 96.4 vs. 96.4%, respectively). MICAB is a safe alternative to OPCAB, particularly in patients with AMI and dilated LV. MICAB is associated with high rates of complete revascularization and acute graft patency, adequate preservation of end‐organ function, and early and mid‐term results comparable with those observed following OPCAB.