Marvin Reimold
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Marvin Reimold has a total of 106 co-authors. Here are the top co-authors by number of shared publications:
- Ulrich Schramm
Helmholtz-Zentrum Dresden-Rossendorf
13 shared publications - Josefine Metzkes-Ng
Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
12 shared publications - Florian Kroll
Helmholtz-Zentrum Dresden - Rossendorf, Dresden, 01328, Germany
10 shared publications - Florian-Emanuel Brack
Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
10 shared publications - Karl Zeil
Helmholtz-Zentrum Dresden-Rossendorf, Dresden, Germany
10 shared publications - Jörg Pawelke
OncoRay - National Center for Radiation Research in Oncology, Medical Faculty and University Hospital Carl Gustav Carus, Technische Universität Dresden
7 shared publications
Latest Publications
- Open Access
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Publisher’s Note: “Absolute energy-dependent scintillating screen calibration for real-time detection of laser-accelerated proton bunches” [Rev. Sci. Instrum. 95, 073303 (2024)]
This article was originally published online on 26 July 2024 with missing affiliations for several authors. All author affiliations appear correctly above. AIP This article was originally published online on 26 July 2024 with missing affiliations for several authors. All author affiliations appear correctly above. AIP
- 1 September 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (9)
Open AccessPublisher’s Note: “Absolute energy-dependent scintillating screen calibration for real-time detection of laser-accelerated proton bunches” [Rev. Sci. Instrum. 95, 073303 (2024)]
This article was originally published online on 26 July 2024 with missing affiliations for several authors. All author affiliations appear correctly above. AIP This article was originally published online on 26 July 2024 with missing affiliations for several authors. All author affiliations appear correctly above. AIP
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Scintillator Detector for Spatiospectral Characterization of Proton Beams at High Repetition Rate
We present the experimental results of a 2-D scintillator-based detector developed at the Centro de Laseres Pulsados (CLPU) aiming at the spatiospectral characterization of proton beams driven by ultrarelativistic laser pulses at a high repetition rate (HRR). We report its implementation in laser-driven proton acceleration at the VEGA (CLPU) laser facility to demonstrate its operation. The analysis of the obtained results shows the relevance of the presented diagnostic for HRR acquisition of laser-driven proton sources promoting it as an essential tool for large parametric studies in the emerging field of laser-driven accelerators. A validation of the spectral and divergence reconstruction method is also presented together with the scintillator calibration performed at the conventional accelerator Centro de Micro-Análisis de Materiales (CMAM) in Madrid, Spain.
- 23 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-12
A Scintillator Detector for Spatiospectral Characterization of Proton Beams at High Repetition Rate
We present the experimental results of a 2-D scintillator-based detector developed at the Centro de Laseres Pulsados (CLPU) aiming at the spatiospectral characterization of proton beams driven by ultrarelativistic laser pulses at a high repetition rate (HRR). We report its implementation in laser-driven proton acceleration at the VEGA (CLPU) laser facility to demonstrate its operation. The analysis of the obtained results shows the relevance of the presented diagnostic for HRR acquisition of laser-driven proton sources promoting it as an essential tool for large parametric studies in the emerging field of laser-driven accelerators. A validation of the spectral and divergence reconstruction method is also presented together with the scintillator calibration performed at the conventional accelerator Centro de Micro-Análisis de Materiales (CMAM) in Madrid, Spain.
- Open Access
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Absolute energy-dependent scintillating screen calibration for real-time detection of laser-accelerated proton bunches
Laser-plasma accelerators (LPAs) can deliver pico- to nanosecond long proton bunches with ≳100 nC of charge dispersed over a broad energy spectrum. Increasing the repetition rates of today’s LPAs is a necessity for their practical application. This, however, creates a need for real-time proton bunch diagnostics. Scintillating screens are one detector solution commonly applied in the field of electron LPAs for spatially resolved particle and radiation detection. Yet their establishment for LPA proton detection is only slowly taking off, also due to the lack of available calibrations. In this paper, we present an absolute proton number calibration for the scintillating screen type DRZ High (Mitsubishi Chemical Corporation, Düsseldorf, Germany), one of the most sensitive screens according to calibrations for relativistic electrons and x rays. The presented absolute light yield calibration shows an uncertainty of the proton number of 10% and can seamlessly be applied at other LPA facilities. For proton irradiation of the DRZ High screen, we find an increase in light yield of >60% compared to reference calibration data for relativistic electrons. Moreover, we investigate the scintillating screen light yield dependence on proton energy since many types of scintillators (e.g., plastic, liquid, and inorganic) show a reduced light yield for increased local energy deposition densities, an effect termed ionization quenching. The ionization quenching can reduce the light yield for low-energy protons by up to ∼20%. This work provides all necessary data for absolute spectral measurements of LPA protons with DRZ High scintillating screens, e.g., when used in the commonly applied Thomson parabola spectrometers.
- 1 July 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (7)
Open AccessAbsolute energy-dependent scintillating screen calibration for real-time detection of laser-accelerated proton bunches
Laser-plasma accelerators (LPAs) can deliver pico- to nanosecond long proton bunches with ≳100 nC of charge dispersed over a broad energy spectrum. Increasing the repetition rates of today’s LPAs is a necessity for their practical application. This, however, creates a need for real-time proton bunch diagnostics. Scintillating screens are one detector solution commonly applied in the field of electron LPAs for spatially resolved particle and radiation detection. Yet their establishment for LPA proton detection is only slowly taking off, also due to the lack of available calibrations. In this paper, we present an absolute proton number calibration for the scintillating screen type DRZ High (Mitsubishi Chemical Corporation, Düsseldorf, Germany), one of the most sensitive screens according to calibrations for relativistic electrons and x rays. The presented absolute light yield calibration shows an uncertainty of the proton number of 10% and can seamlessly be applied at other LPA facilities. For proton irradiation of the DRZ High screen, we find an increase in light yield of >60% compared to reference calibration data for relativistic electrons. Moreover, we investigate the scintillating screen light yield dependence on proton energy since many types of scintillators (e.g., plastic, liquid, and inorganic) show a reduced light yield for increased local energy deposition densities, an effect termed ionization quenching. The ionization quenching can reduce the light yield for low-energy protons by up to ∼20%. This work provides all necessary data for absolute spectral measurements of LPA protons with DRZ High scintillating screens, e.g., when used in the commonly applied Thomson parabola spectrometers.
- Top Cited PapersOpen Access
- 13 May 2024
- Published by Springer Nature in Nature Physics
- Vol. 20 (7) , 1211-1216
Laser-driven high-energy proton beams from cascaded acceleration regimes
Laser-driven ion accelerators can deliver high-energy, high-peak current beams and are thus attracting attention as a compact alternative to conventional accelerators. However, achieving sufficiently high energy levels suitable for applications such as radiation therapy remains a challenge for laser-driven ion accelerators. Here we generate proton beams with a spectrally separated high-energy component of up to 150 MeV by irradiating solid-density plastic foil targets with ultrashort laser pulses from a repetitive petawatt laser. The preceding laser light heats the target, leading to the onset of relativistically induced transparency upon main pulse arrival. The laser peak then penetrates the initially opaque target and triggers proton acceleration through a cascade of different mechanisms, as revealed by three-dimensional particle-in-cell simulations. The transparency of the target can be used to identify the high-performance domain, making it a suitable feedback parameter for automated laser and target optimization to enhance stability of plasma accelerators in the future.
- 13 May 2024
- Published by Springer Nature in Nature Physics
- Vol. 20 (7) , 1211-1216
Top Cited PapersOpen AccessLaser-driven high-energy proton beams from cascaded acceleration regimes
Laser-driven ion accelerators can deliver high-energy, high-peak current beams and are thus attracting attention as a compact alternative to conventional accelerators. However, achieving sufficiently high energy levels suitable for applications such as radiation therapy remains a challenge for laser-driven ion accelerators. Here we generate proton beams with a spectrally separated high-energy component of up to 150 MeV by irradiating solid-density plastic foil targets with ultrashort laser pulses from a repetitive petawatt laser. The preceding laser light heats the target, leading to the onset of relativistically induced transparency upon main pulse arrival. The laser peak then penetrates the initially opaque target and triggers proton acceleration through a cascade of different mechanisms, as revealed by three-dimensional particle-in-cell simulations. The transparency of the target can be used to identify the high-performance domain, making it a suitable feedback parameter for automated laser and target optimization to enhance stability of plasma accelerators in the future.
- Open Access
- 23 January 2024
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 12, 1-11
miniSCIDOM: a scintillator-based tomograph for volumetric dose reconstruction of single laser-driven proton bunches
Laser plasma accelerators (LPAs) enable the generation of intense and short proton bunches on a micrometre scale, thus offering new experimental capabilities to research fields such as ultra-high dose rate radiobiology or material analysis. Being spectrally broadband, laser-accelerated proton bunches allow for tailored volumetric dose deposition in a sample via single bunches to excite or probe specific sample properties. The rising number of such experiments indicates a need for diagnostics providing spatially resolved characterization of dose distributions with volumes of approximately 1 cm ${}^3$ for single proton bunches to allow for fast online feedback. Here we present the scintillator-based miniSCIDOM detector for online single-bunch tomographic reconstruction of dose distributions in volumes of up to approximately 1 cm ${}^3$ . The detector achieves a spatial resolution below 500 $\unicode{x3bc}$ m and a sensitivity of 100 mGy. The detector performance is tested at a proton therapy cyclotron and an LPA proton source. The experiments’ primary focus is the characterization of the scintillator’s ionization quenching behaviour.- 23 January 2024
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 12, 1-11
Open AccessminiSCIDOM: a scintillator-based tomograph for volumetric dose reconstruction of single laser-driven proton bunches
Laser plasma accelerators (LPAs) enable the generation of intense and short proton bunches on a micrometre scale, thus offering new experimental capabilities to research fields such as ultra-high dose rate radiobiology or material analysis. Being spectrally broadband, laser-accelerated proton bunches allow for tailored volumetric dose deposition in a sample via single bunches to excite or probe specific sample properties. The rising number of such experiments indicates a need for diagnostics providing spatially resolved characterization of dose distributions with volumes of approximately 1 cm ${}^3$ for single proton bunches to allow for fast online feedback. Here we present the scintillator-based miniSCIDOM detector for online single-bunch tomographic reconstruction of dose distributions in volumes of up to approximately 1 cm ${}^3$ . The detector achieves a spatial resolution below 500 $\unicode{x3bc}$ m and a sensitivity of 100 mGy. The detector performance is tested at a proton therapy cyclotron and an LPA proton source. The experiments’ primary focus is the characterization of the scintillator’s ionization quenching behaviour. - Open Access
- 8 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (18) , 185009
Dosimetry for radiobiological in vivo experiments at laser plasma-based proton accelerators
Objective. Laser plasma-based accelerators (LPAs) of protons can contribute to research of ultra-high dose rate radiobiology as they provide pulse dose rates unprecedented at medical proton sources. Yet, LPAs pose challenges regarding precise and accurate dosimetry due to the high pulse dose rates, but also due to the sources’ lower spectral stability and pulsed operation mode. For in vivo models, further challenges arise from the necessary small field dosimetry for volumetric dose distributions. For these novel source parameters and intended applications, a dosimetric standard needs to be established. Approach. In this work, we present a dosimetry and beam monitoring framework for in vivo irradiations of small target volumes with LPA protons, solving aforementioned challenges. The volumetric dose distribution in a sample (mean dose value and lateral/depth dose inhomogeneity) is provided by combining two independent dose measurements using radiochromic films (dose rate-independent) and ionization chambers (dose rate-dependent), respectively. The unique feature of the dosimetric setup is beam monitoring with a transmission time-of-flight spectrometer to quantify spectral fluctuations of the irradiating proton pulses. The resulting changes in the depth dose profile during irradiation of an in vivo sample are hence accessible and enable pulse-resolved depth dose correction for each dose measurement. Main results. A first successful small animal pilot study using an LPA proton source serves as a testcase for the presented dosimetry approach and proves its performance in a realistic setting. Significance. With several facilities worldwide either setting up or already using LPA infrastructure for radiobiological studies with protons, the importance of LPA-adapted dosimetric frameworks as presented in this work is clearly underlined.
- 8 September 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 68 (18) , 185009
Open AccessDosimetry for radiobiological in vivo experiments at laser plasma-based proton accelerators
Objective. Laser plasma-based accelerators (LPAs) of protons can contribute to research of ultra-high dose rate radiobiology as they provide pulse dose rates unprecedented at medical proton sources. Yet, LPAs pose challenges regarding precise and accurate dosimetry due to the high pulse dose rates, but also due to the sources’ lower spectral stability and pulsed operation mode. For in vivo models, further challenges arise from the necessary small field dosimetry for volumetric dose distributions. For these novel source parameters and intended applications, a dosimetric standard needs to be established. Approach. In this work, we present a dosimetry and beam monitoring framework for in vivo irradiations of small target volumes with LPA protons, solving aforementioned challenges. The volumetric dose distribution in a sample (mean dose value and lateral/depth dose inhomogeneity) is provided by combining two independent dose measurements using radiochromic films (dose rate-independent) and ionization chambers (dose rate-dependent), respectively. The unique feature of the dosimetric setup is beam monitoring with a transmission time-of-flight spectrometer to quantify spectral fluctuations of the irradiating proton pulses. The resulting changes in the depth dose profile during irradiation of an in vivo sample are hence accessible and enable pulse-resolved depth dose correction for each dose measurement. Main results. A first successful small animal pilot study using an LPA proton source serves as a testcase for the presented dosimetry approach and proves its performance in a realistic setting. Significance. With several facilities worldwide either setting up or already using LPA infrastructure for radiobiological studies with protons, the importance of LPA-adapted dosimetric frameworks as presented in this work is clearly underlined.
- Open Access
- 7 July 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-11
Ultra-short pulse laser acceleration of protons to 80 MeV from cryogenic hydrogen jets tailored to near-critical density
Laser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes. Here, we demonstrate that the interaction of petawatt-class laser pulses with a pre-formed micrometer-sized cryogenic hydrogen jet plasma overcomes these limitations enabling tailored density scans from the solid to the underdense regime. Our proof-of-concept experiment demonstrates that the near-critical plasma density profile produces proton energies of up to 80 MeV. Based on hydrodynamic and three-dimensional particle in cell simulations, transition between different acceleration schemes are shown, suggesting enhanced proton acceleration at the relativistic transparency front for the optimal case.
- 7 July 2023
- Published by Springer Nature in Nature Communications
- Vol. 14 (1) , 1-11
Open AccessUltra-short pulse laser acceleration of protons to 80 MeV from cryogenic hydrogen jets tailored to near-critical density
Laser plasma-based particle accelerators attract great interest in fields where conventional accelerators reach limits based on size, cost or beam parameters. Despite the fact that particle in cell simulations have predicted several advantageous ion acceleration schemes, laser accelerators have not yet reached their full potential in producing simultaneous high-radiation doses at high particle energies. The most stringent limitation is the lack of a suitable high-repetition rate target that also provides a high degree of control of the plasma conditions required to access these advanced regimes. Here, we demonstrate that the interaction of petawatt-class laser pulses with a pre-formed micrometer-sized cryogenic hydrogen jet plasma overcomes these limitations enabling tailored density scans from the solid to the underdense regime. Our proof-of-concept experiment demonstrates that the near-critical plasma density profile produces proton energies of up to 80 MeV. Based on hydrodynamic and three-dimensional particle in cell simulations, transition between different acceleration schemes are shown, suggesting enhanced proton acceleration at the relativistic transparency front for the optimal case.
- Open Access
- 4 July 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-15
OCTOPOD: single-bunch tomography for angular-spectral characterization of laser-driven protons
Laser–plasma accelerated (LPA) proton bunches are now applied for research fields ranging from ultra-high-dose-rate radiobiology to material science. Yet, the capabilities to characterize the spectrally and angularly broad LPA bunches lag behind the rapidly evolving applications. The OCTOPOD translates the angularly resolved spectral characterization of LPA proton bunches into the spatially resolved detection of the volumetric dose distribution deposited in a liquid scintillator. Up to 24 multi-pinhole arrays record projections of the scintillation light distribution and allow for tomographic reconstruction of the volumetric dose deposition pattern, from which proton spectra may be retrieved. Applying the OCTOPOD at a cyclotron, we show the reliable retrieval of various spatial dose deposition patterns and detector sensitivity over a broad dose range. Moreover, the OCTOPOD was installed at an LPA proton source, providing real-time data on proton acceleration performance and attesting the system optimal performance in the harsh laser–plasma environment.
- 4 July 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-15
Open AccessOCTOPOD: single-bunch tomography for angular-spectral characterization of laser-driven protons
Laser–plasma accelerated (LPA) proton bunches are now applied for research fields ranging from ultra-high-dose-rate radiobiology to material science. Yet, the capabilities to characterize the spectrally and angularly broad LPA bunches lag behind the rapidly evolving applications. The OCTOPOD translates the angularly resolved spectral characterization of LPA proton bunches into the spatially resolved detection of the volumetric dose distribution deposited in a liquid scintillator. Up to 24 multi-pinhole arrays record projections of the scintillation light distribution and allow for tomographic reconstruction of the volumetric dose deposition pattern, from which proton spectra may be retrieved. Applying the OCTOPOD at a cyclotron, we show the reliable retrieval of various spatial dose deposition patterns and detector sensitivity over a broad dose range. Moreover, the OCTOPOD was installed at an LPA proton source, providing real-time data on proton acceleration performance and attesting the system optimal performance in the harsh laser–plasma environment.
- Open Access
- 19 May 2023
- Published by Springer Nature in Research Square
Laser-driven high-energy proton beams from cascaded acceleration regimes
Laser-driven ion accelerators can deliver high-energy, high peak current beams from relativistic laser plasmas formed in solid-density materials [1, 2]. This innovative concept attracts a lot of attention for various multidisciplinary applications as a compact alternative to conventional accelerators [3]. However, achieving energy levels suitable for applications such as radiation therapy remains a challenge for laser-driven ion accelerators. Here, we report on experimental generation of plasma-accelerated proton beams with a spectrally separated high-energy component of up to 150MeV by irradiating solid-density plastic foil targets with ultrashort laser pulses from a repetitive Petawatt laser. Three-dimensional particle-in-cell simulations reveal that the observed beam parameters result from cascaded acceleration regimes that occur at the onset of relativistically induced transparency. The ultrashort pulse duration allows a rapid sequence of these regimes at highest intensity, enabling proton acceleration to unprecedented energy levels. Target transparency was identified to discriminate the high-performance domain of the acquired data set, making it a suitable feedback parameter for automated laser and target optimisation to enhance stability of plasma accelerators in the future. Ultimately, our results encourage further exploration and application of laser-driven plasmas as compact proton accelerators in the multi-100MeV range.
- 19 May 2023
- Published by Springer Nature in Research Square
Open AccessLaser-driven high-energy proton beams from cascaded acceleration regimes
Laser-driven ion accelerators can deliver high-energy, high peak current beams from relativistic laser plasmas formed in solid-density materials [1, 2]. This innovative concept attracts a lot of attention for various multidisciplinary applications as a compact alternative to conventional accelerators [3]. However, achieving energy levels suitable for applications such as radiation therapy remains a challenge for laser-driven ion accelerators. Here, we report on experimental generation of plasma-accelerated proton beams with a spectrally separated high-energy component of up to 150MeV by irradiating solid-density plastic foil targets with ultrashort laser pulses from a repetitive Petawatt laser. Three-dimensional particle-in-cell simulations reveal that the observed beam parameters result from cascaded acceleration regimes that occur at the onset of relativistically induced transparency. The ultrashort pulse duration allows a rapid sequence of these regimes at highest intensity, enabling proton acceleration to unprecedented energy levels. Target transparency was identified to discriminate the high-performance domain of the acquired data set, making it a suitable feedback parameter for automated laser and target optimisation to enhance stability of plasma accelerators in the future. Ultimately, our results encourage further exploration and application of laser-driven plasmas as compact proton accelerators in the multi-100MeV range.
- Open Access
- 23 February 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-9
Three-dimensional acoustic monitoring of laser-accelerated protons in the focus of a pulsed-power solenoid lens
The acoustic pulse emitted from the Bragg peak of a laser-accelerated proton bunch focused into water has recently enabled the reconstruction of the bunch energy distribution. By adding three ultrasonic transducers and implementing a fast data analysis of the filtered raw signals, I-BEAT (Ion-Bunch Energy Acoustic Tracing) 3D now provides the mean bunch energy and absolute lateral bunch position in real-time and for individual bunches. Relative changes in energy spread and lateral bunch size can also be monitored. Our experiments at DRACO with proton bunch energies between 10 and 30 MeV reveal sub-MeV and sub-mm resolution. In addition to this 3D bunch information, the signal strength correlates also with the absolute bunch particle number.
- 23 February 2023
- Published by Cambridge University Press (CUP) in High Power Laser Science and Engineering
- Vol. 11, 1-9
Open AccessThree-dimensional acoustic monitoring of laser-accelerated protons in the focus of a pulsed-power solenoid lens
The acoustic pulse emitted from the Bragg peak of a laser-accelerated proton bunch focused into water has recently enabled the reconstruction of the bunch energy distribution. By adding three ultrasonic transducers and implementing a fast data analysis of the filtered raw signals, I-BEAT (Ion-Bunch Energy Acoustic Tracing) 3D now provides the mean bunch energy and absolute lateral bunch position in real-time and for individual bunches. Relative changes in energy spread and lateral bunch size can also be monitored. Our experiments at DRACO with proton bunch energies between 10 and 30 MeV reveal sub-MeV and sub-mm resolution. In addition to this 3D bunch information, the signal strength correlates also with the absolute bunch particle number.