SSSteven Seeger

Steven Seeger

*This is an algorithmically generated author record based on publicly available information.

Steven Seeger has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Inclusion of Inter-crystal Scattering in PET: Analytical Models and Dedicated Reconstruction

    by Jorge Roser, Hong Phuc Vo, Rebecca Kantorek, Steven Seeger, Magdalena Rafecas

    Inter-crystal scattering (ICS) in Positron Emission Tomography (PET) is commonly regarded as a degradation effect that might compromise the image spatial resolution. In parallel, the inclusion of ICS events has also been recognized as a potential approach to increase PET sensitivity, which could be especially beneficial in scenarios where the latter is a limiting factor, such as very small animal imaging. Several methods for the recovery of ICS events have been proposed, many of which aim to locate the first interaction, i.e., the Compton scattering site, usually limited by their success rate, computational burden or data and training dependency. Conversely, this work proposes a physics-based model for ICS events, leading to analytical expressions of the sensitivity image and the system matrix (required by statistical reconstruction algorithms), without the need to identify the original line of response. After validating the model, the work shows how ICS events can be integrated into a joint image reconstruction algorithm (based on list-mode MLEM) together with conventional PET events, for which dedicated analytical models are also developed. To assess the performance of the proposed approach, Monte-Carlo simulated and experimental data of an image quality phantom were obtained with the MERMAID small-fish PET scanner prototype. Both simulation and experimental results indicate that, while slightly decreasing the recovery coefficient values, the inclusion of ICS clearly reduces statistical noise and improves uniformity.

  • Open Access

    Dedicated 3D-Printed Radioactive Phantoms With ¹⁸F-FDG for Ultrahigh-Resolution PET

    by Ezzat Elmoujarkach, Steven Seeger, Luise Morgner, Fabian Schmidt, Julia G. Mannheim, Christian L. Schmidt, Magdalena Rafecas

    This study explores the potential of digital light processing to 3D print radioactive phantoms for high-resolution positron emission tomography (PET). Using a slightly modified desktop 3D printer and mixtures of 18F-FDG (T1/2: 109.8 minutes) and photopolymer resin, we have printed standardized and custom radioactive objects designed for ultra-high-resolution PET, also as a first step toward complex geometries. The phantoms were: a flood source to assess uniformity, a two-point phantom for spatial resolution assessment, a multi-line phantom for validating submillimeter printing resolution, a fish-like phantom with different activity concentrations, and a 50%-downscaled micro-PET image quality phantom (NEMA NU 4-2008). Positron range effects were examined on the latter using a removable cover. The evaluation relied on planar images from a phosphor imager and tomographic images from a commercial small animal PET scanner. We were able to print radioactive uniform distributions with relative standard deviation below 4.5% and structures as small as 0.3 mm. Our two-point phantom outperformed a commercial one in terms of peak difference (6% vs. 72%) and peak-to-valley ratio (75.3 vs. 14.1). The fish-like phantom shows that printing hot regions and air cavities onto a uniform background is feasible. Future steps include using longer-lived radionuclides like 89Zr and 22Na.


  • Open Access

    Development of a digital zebrafish phantom and its application to dedicated small-fish PET

    by M Zvolský, M Schaar, S Seeger, S Rakers, M Rafecas

    Objective . We are developing a small-fish positron emission tomography (PET) scanner dedicated to small aquatic animals relevant for biomedical and biological research, e.g. zebrafish. We plan to use Monte Carlo simulations to optimize its configuration and the required water-filled imaging chambers. Our objectives were: (1) to create a digital 3D zebrafish phantom using conventional micro-CT, (2) include the phantom into a simulated PET environment based on the framework GATE, and (3) investigate the effects of the water environment on the reconstructed images. Approach . To create the phantom, we performed ex vivo measurements of zebrafish specimen using a tabletop micro-CT and compared three methods to fixate the specimen. From segmented micro-CT images we created digital emission and transmission phantoms which were incorporated in GATE via tessellated volumes. Two chamber sizes were considered. For reference, a simulation with the zebrafish in air was implemented. The simulated data were reconstructed using CASToR. For attenuation correction, we used the exact attenuation information or a uniform distribution (only water). Several realizations of each scenario were performed; the reconstructed images were quantitatively evaluated. Main results . Fixation in formalin led to the best soft-tissue contrast at the cost of some specimen deformation. After attenuation correction, no significant differences were found between the reconstructed images. The PET images reflected well the higher uptake simulated in the brain and heart, despite their small size and surrounding background activity; the swim bladder (no activity) was clearly identified. The simplified attenuation map, consisting only of water, slightly worsened the images. Significance . A conventional micro-CT can provide sufficient image quality to generate numerical phantoms of small fish without contrast media. Such phantoms are useful to evaluate in-silico small aquatic animal imaging concepts and develop imaging protocols. Our results support the feasibility of zebrafish PET with an aqueous environment.


  • Dedicated Chamber for Multimodal In Vivo Imaging of Adult Zebrafish

    by Steven Seeger, Milan Zvolský, Salim Melikov, Maja Frerkes, Magdalena Rafecas

    In vivo imaging of adult zebrafish is challenging, particularly for dynamic or long acquisitions when using, for example, positron emission tomography, single photon emission computed tomography, computed tomography (CT), or magnetic resonance imaging (MRI). An aqueous environment is indispensable to ensure animal welfare, but commercial small-animal imaging chambers do not provide such conditions, as they are designed for rodents. In this study we present a dedicated flow-through chamber that includes fish immobilization and allows for the continuous supply of fresh water and anesthetics, as well as the removal of excretions. Both flow simulations and experiments, as well as first scans with MRI and CT, support the suitability of the chamber.