CCCalvo-Vargas César

Calvo-Vargas César

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Calvo-Vargas César has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Loaned self-measurement equipment model compared with ambulatory blood pressure monitoring

    by Calvo-Vargas César, Padilla-Rios Victoria, Troyo-Sanromán Rogelio

    To compare the correspondence between the loaned self-measurement equipment model (LSEM), 24 h awake ambulatory blood pressure monitoring (ABPM) and clinic blood pressure (CBP). A cross-sectional study was carried out involving 90 hypertensive and normotensive subjects. We used a variation of home measurement, the loaned self-measurement equipment model (LSEM), that consisted of lending a number of sphygmomanometers, the property of the clinic, to patients for 3-day periods. The correspondence of results from LSEM was measured against the difference between the two averages, the correlation coefficients and the average unweighted absolute differences. The average difference between CBP and ABPM was 6.1/2.5 mmHg (P<0.001, r =0.54/0.63). Between CBP and LSEM, it was 6.6/1.4 mmHg (P<0.001/ 0.08, r =0.52/0.63), and between the ABPM and LSEM 0.5/−1.0 mmHg (P=0.70/0.14, r =0.71/0.75). The average unweighted absolute differences between LSEM and ABPM readings were 5.5 and 1.5 mmHg for systolic and diastolic blood pressure, respectively, whereas the average difference between CBP and ABPM means was much higher, at 6.8 mmHg for systolic and 2.7 mmHg for diastolic pressure. Agreement in the diagnosis of systolic hypertension between LSEM and ABPM was found in 78.8% of the individuals, and of diastolic hypertension in 76.7%. Blood pressure readings taken using LSEM have a better correspondence than CBP in predicting the awake ABPM value, although the disagreement in terms of diagnosing hypertension should be noted.


  • Reproducibility and cost of blood pressure self-measurement using the ‘Loaned Self-measurement Equipment Model’

    by César Calvo-Vargas, Victoria Padilla Rios, Rogelio Troyo-Sanromán, Fernando Grover-Paez

    To determine the reproducibility and the cost of the Loaned Self-measurement Equipment Model for blood pressure. Seventy-five subjects with non-complicated essential hypertension, having an average age of 56.2 +/- 11 years, were evaluated. The Loaned Self-measurement Equipment Model consists of a set of sphygmomanometers belonging to the clinic, loaned to patients for 3-day periods for them to carry out 27 readings, and then returned. Using a mercury sphygmomanometer, a nurse carried out office blood pressure readings during two visits. A month later, the same procedure was repeated under the same clinical conditions. The agreement between studies was assessed by correlation coefficients, coefficients of variation and standard deviation of the differences (SDD). The office blood pressure was 147 +/- 17/89 +/- 12 mmHg during visit A, and 145 +/- 16/88 +/- 11 mmHg during visit B. The self-measurement blood pressure was 139 +/- 16/84 +/- 10 mmHg during the first visit, and 136 +/- 15/84 +/- 11 mmHg during the second visit. In neither of the cases were the differences statistically significant. The correlation coefficients for the office and self-measurement systolic blood pressure were statistically significant (P = 0.018), while those for the diastolic blood pressure were not statistically significant. The SDD for self-measurement systolic blood pressure was 10.7, compared to 15.0 for the office blood pressure (P < 0.01). The comparison in the case of diastolic blood pressure was not significant. The cost of each loan was $5.85 (US dollars). The Loaned Self-measurement Equipment Model has a good short-term reproducibility, and the cost is reasonable.