Zeeshan Zaheer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Zeeshan Zaheer has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Aiman Mohammed
Faculty of Civil Engineering and Built Environment, University Tun Hussein Onn Malaysia, Parit Raja 86400, Malaysia
1 shared publication - Anne Wai Man Ng
College of Engineering, Information Technology and Environment, Charles Darwin University, Brinkin, Australia
1 shared publication - Hooman Mehdizadeh-Rad
Faculty of Science and Technology Charles Darwin University Darwin Australia
1 shared publication - Mahmood Mohammed
Faculty of Engineering, University Putra Malaysia, Seri Kembangan 43400, Malaysia
1 shared publication - Muhammad Atiq Ur Rehman Tariq
Centre of Excellence in Water Resources Engineering, University of Engineering and Technology, Lahore, Pakistan
1 shared publication - Safwan Sadeq
Department of Mechanical Engineering Universiti Teknologi Petronas Perak Malaysia
1 shared publication
Latest Publications
- Open Access
- 23 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 3775
Reducing the Cooling Loads of Buildings Using Shading Devices: A Case Study in Darwin
It is estimated that almost 40% of the world’s energy is consumed by buildings’ heating, ventilation, and air conditioning systems. This consumption increases by 3% every year and will reach 70% by 2050 due to rapid urbanisation and population growth. In Darwin, building energy consumption is even higher and accounts for up to 55% due to the hot and humid weather conditions. Singapore has the same weather conditions but less energy consumption, with only 38% compared to Darwin. Solar radiation can be defined as electromagnetic radiation emitted by the Sun and the Darwin area receives a large amount of solar radiation; building energy consumption can be reduced hugely if this radiation is blocked effectively by analysing appropriate shading devices. This study investigated the influence of different types of shading devices on the cooling load of a town hall building located in Darwin, Australia, and proposed the optimal shading device. The results showed that the horizontal fins led to a 5% reduction in the cooling load of the building. In contrast, adding a variation to the device angles and length increased the savings to 8%. The results demonstrated that the overhangs were more efficient than the fins, contributing 9.2% energy savings, and the cooling reduction savings were increased to 15.5% with design and length variations.
- 23 March 2022
- Published by MDPI AG in Sustainability
- Vol. 14 (7) , 3775
Open AccessReducing the Cooling Loads of Buildings Using Shading Devices: A Case Study in Darwin
It is estimated that almost 40% of the world’s energy is consumed by buildings’ heating, ventilation, and air conditioning systems. This consumption increases by 3% every year and will reach 70% by 2050 due to rapid urbanisation and population growth. In Darwin, building energy consumption is even higher and accounts for up to 55% due to the hot and humid weather conditions. Singapore has the same weather conditions but less energy consumption, with only 38% compared to Darwin. Solar radiation can be defined as electromagnetic radiation emitted by the Sun and the Darwin area receives a large amount of solar radiation; building energy consumption can be reduced hugely if this radiation is blocked effectively by analysing appropriate shading devices. This study investigated the influence of different types of shading devices on the cooling load of a town hall building located in Darwin, Australia, and proposed the optimal shading device. The results showed that the horizontal fins led to a 5% reduction in the cooling load of the building. In contrast, adding a variation to the device angles and length increased the savings to 8%. The results demonstrated that the overhangs were more efficient than the fins, contributing 9.2% energy savings, and the cooling reduction savings were increased to 15.5% with design and length variations.