Mengze Yu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mengze Yu has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Feng Li
Grid Planning and Research Centre, Guangdong Power Grid Co., Ltd., Guangzhou 510000, China
1 shared publication - Jiajun Mei
School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
1 shared publication - Jiaxin Yuan
Wuhan University
1 shared publication - Jinchao Chen
State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University, Xi’an 710049, China
1 shared publication - Shunkai Xu
School of Electrical and Automation, Wuhan University, No. 299, Bayi Street, Wuchang District, Wuhan 430072, China
1 shared publication - Siyuan Liu
Xi’an Jiaotong University
1 shared publication
Latest Publications
- Open Access
- 16 May 2024
- Published by MDPI AG in Electronics
- Vol. 13 (10) , 1948
A Cost-Effective Current-Limiting Hybrid DC Circuit Breaker Based on Hybrid Semiconductors
DC circuit breakers (DCCBs) are the key equipment to rapidly interrupt the fault current in high-voltage DC power grids and ensure the safe operation of the system. However, most DCCBs do not take current-limiting measures and rely solely on current-limiting reactors in the system to limit the rate of current rise during the interruption process. The extensive use of fully controlled power electronic devices in circuit breakers (CBs) results in high costs. To address the issues above, this paper proposes a DCCB topology with a current-limiting function based on thyristors and diodes, which can reduce the cost of CB while ensuring reliable interruption. The impact of various parameters on CB performance is analyzed using numerical calculations to optimize the parameters. Then, a simulation model of a 500 kV/16 kA DCCB is built in PSCAD/EMTDC, and the performance of the proposed CB topology is compared with the other CB topologies. By comparison, the proposed DCCB topology can reliably isolate fault currents and reduce the amplitude of fault currents and the cost of CBs. Significantly, the energy absorbed by the metal oxide varistor (MOV) during the interruption process decreases by 64.2%, reducing the cost and volume of the MOV. Finally, the feasibility of the CB is further verified in the ±500 kV 4-terminal high-voltage DC power grid simulation model. The results show that the proposed DCCB topology can limit the fault current rise rate, interrupt and isolate the fault reliably, and reduce the cost.
- 16 May 2024
- Published by MDPI AG in Electronics
- Vol. 13 (10) , 1948
Open AccessA Cost-Effective Current-Limiting Hybrid DC Circuit Breaker Based on Hybrid Semiconductors
DC circuit breakers (DCCBs) are the key equipment to rapidly interrupt the fault current in high-voltage DC power grids and ensure the safe operation of the system. However, most DCCBs do not take current-limiting measures and rely solely on current-limiting reactors in the system to limit the rate of current rise during the interruption process. The extensive use of fully controlled power electronic devices in circuit breakers (CBs) results in high costs. To address the issues above, this paper proposes a DCCB topology with a current-limiting function based on thyristors and diodes, which can reduce the cost of CB while ensuring reliable interruption. The impact of various parameters on CB performance is analyzed using numerical calculations to optimize the parameters. Then, a simulation model of a 500 kV/16 kA DCCB is built in PSCAD/EMTDC, and the performance of the proposed CB topology is compared with the other CB topologies. By comparison, the proposed DCCB topology can reliably isolate fault currents and reduce the amplitude of fault currents and the cost of CBs. Significantly, the energy absorbed by the metal oxide varistor (MOV) during the interruption process decreases by 64.2%, reducing the cost and volume of the MOV. Finally, the feasibility of the CB is further verified in the ±500 kV 4-terminal high-voltage DC power grid simulation model. The results show that the proposed DCCB topology can limit the fault current rise rate, interrupt and isolate the fault reliably, and reduce the cost.
- Open Access
Power Flow Optimization and Economic Analysis Based on High Voltage Phase Shifting Transformer
With the development of power systems, the power flow problem of transmission line is becoming more and more prominent. This paper presents a power flow regulation method based on phase shifting transformer (PST). Firstly, the working principle and performance of PST are analyzed. Then, the simulation model of BPA multi node system is established. PST access reduces the line imbalance to less than 8%. On this basis, considering the influence of saturation effect and leakage reactance, a PST suitable for 220 kV power grid is designed. Three different working conditions are simulated by PSCAD software. Under normal working conditions and N-1 conditions, PST can increase the transmission limit of the ring network section by more than 20%. When a short-circuit fault occurs, PST can also suppress the fault current. For 220 kV practical projects, unified power flow controller (UPFC) has faster response speed and stronger performance, but PST is more economical and reliable, and the equipment cost is 49.86% lower than that of UPFC. The power flow regulation method based on PST has good steady-state effect. It can improve the utilization efficiency of power grid assets and optimize the power flow distribution in a short time and at low cost.
Open AccessPower Flow Optimization and Economic Analysis Based on High Voltage Phase Shifting Transformer
With the development of power systems, the power flow problem of transmission line is becoming more and more prominent. This paper presents a power flow regulation method based on phase shifting transformer (PST). Firstly, the working principle and performance of PST are analyzed. Then, the simulation model of BPA multi node system is established. PST access reduces the line imbalance to less than 8%. On this basis, considering the influence of saturation effect and leakage reactance, a PST suitable for 220 kV power grid is designed. Three different working conditions are simulated by PSCAD software. Under normal working conditions and N-1 conditions, PST can increase the transmission limit of the ring network section by more than 20%. When a short-circuit fault occurs, PST can also suppress the fault current. For 220 kV practical projects, unified power flow controller (UPFC) has faster response speed and stronger performance, but PST is more economical and reliable, and the equipment cost is 49.86% lower than that of UPFC. The power flow regulation method based on PST has good steady-state effect. It can improve the utilization efficiency of power grid assets and optimize the power flow distribution in a short time and at low cost.