Shiyou Xu
Research Subjects
Shiyou Xu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
Long Pan
Colgate Technology Center , Piscataway, NJ , USA
9 shared publicationsKe Du
Department of Chemical and Environmental Engineering, University of California - Riverside , Riverside, CA , USA
5 shared publicationsDeon Hines
Colgate Technology Center, Piscataway, USA
4 shared publicationsMichael Stranick
Colgate-Palmolive Technology Center, Piscataway, USA
2 shared publications- Xinye Chen
Department of Chemical and Environmental Engineering, University of California 2 , Riverside, California 92521
2 shared publications Yuxin Liu
Colgate-Palmolive Technology Center, Piscataway, USA
2 shared publications
Latest Publications
- Open Access
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Three-Dimensional (3D) FIB-SEM Topography of Porous Particles
Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) is a sophisticated technique that etches off nanometer-thick layers from a sample while capturing images at each etching step. This approach facilitates comprehensive visualization of both internal and external features of the sample and allows for the assembly of image stacks to generate accurate 3D representations. The capability for 3D reconstruction offered by FIB-SEM is invaluable for elucidating intricate details of the subject under study [ 1]. Porous particles play pivotal roles across a spectrum of applications including dental care [ 2], drug delivery [ 3], and diagnostics [ 4], etc. Their unique morphology and porosity are paramount for their functional efficacy. Hence, there exists a pressing demand for precise and accessible methods to visualize 3D structures of porous particles. In this paper, we introduce a novel methodology reliant on 3D FIB-SEM tomography for visualizing porous silica shells. Our proposed method promises to offer novel insights into the evaluation of porous materials.
- 24 July 2024
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 30 (Supplement)
Open AccessThree-Dimensional (3D) FIB-SEM Topography of Porous Particles
Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM) is a sophisticated technique that etches off nanometer-thick layers from a sample while capturing images at each etching step. This approach facilitates comprehensive visualization of both internal and external features of the sample and allows for the assembly of image stacks to generate accurate 3D representations. The capability for 3D reconstruction offered by FIB-SEM is invaluable for elucidating intricate details of the subject under study [ 1]. Porous particles play pivotal roles across a spectrum of applications including dental care [ 2], drug delivery [ 3], and diagnostics [ 4], etc. Their unique morphology and porosity are paramount for their functional efficacy. Hence, there exists a pressing demand for precise and accessible methods to visualize 3D structures of porous particles. In this paper, we introduce a novel methodology reliant on 3D FIB-SEM tomography for visualizing porous silica shells. Our proposed method promises to offer novel insights into the evaluation of porous materials.
- Open Access
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1228-1229
Applications of SEM/FIB to Drive Development and Innovation in the Oral Care Industry
Scanning electron microscopy (SEM) and focused ion beam (FIB) technology have been becoming increasingly important for the oral care industry due to their abilities to obtain high-resolution images from top surfaces, cross-sectional surfaces, and even in three dimensions, of hard tissues, soft tissues, biofilms, and bacteria [ 1–3]. They have been playing important roles in driving the development and innovation in the oral care industry. In this talk, we will present the applications of SEM/FIB for analyzing the etching of enamel, dentine occlusion, and bacteria attachment on oral tissue.
- 22 July 2023
- Published by Oxford University Press (OUP) in Microscopy and Microanalysis
- Vol. 29 (Supplement) , 1228-1229
Open AccessApplications of SEM/FIB to Drive Development and Innovation in the Oral Care Industry
Scanning electron microscopy (SEM) and focused ion beam (FIB) technology have been becoming increasingly important for the oral care industry due to their abilities to obtain high-resolution images from top surfaces, cross-sectional surfaces, and even in three dimensions, of hard tissues, soft tissues, biofilms, and bacteria [ 1–3]. They have been playing important roles in driving the development and innovation in the oral care industry. In this talk, we will present the applications of SEM/FIB for analyzing the etching of enamel, dentine occlusion, and bacteria attachment on oral tissue.
- Open Access
- 8 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Three-dimensional visualization of dentine occlusion based on FIB-SEM tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- 8 February 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Open AccessThree-dimensional visualization of dentine occlusion based on FIB-SEM tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- Open Access
- 27 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Understanding the dynamics of fluid–structure interaction with an Air Deflected Microfluidic Chip (ADMC)
A deformable microfluidic system and a fluidic dynamic model have been successfully coupled to understand the dynamic fluid–structure interaction in transient flow, designed to understand the dentine hypersensitivity caused by hydrodynamic theory. The Polydimethylsiloxane thin sidewalls of the microfluidic chip are deformed with air pressure ranging from 50 to 500 mbar to move the liquid meniscus in the central liquid channel. The experiments show that the meniscus sharply increased in the first 10th of second and the increase is nonlinearly proportional to the applied pressure. A theoretical model is developed based on the unsteady Bernoulli equation and can well predict the ending point of the liquid displacement as well as the dynamics process, regardless of the wall thickness. Moreover, an overshooting and oscillation phenomenon is observed by reducing the head loss coefficient by a few orders which could be the key to explain the dentine hypersensitivity caused by the liquid movement in the dentine tubules.
- 27 November 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-9
Open AccessUnderstanding the dynamics of fluid–structure interaction with an Air Deflected Microfluidic Chip (ADMC)
A deformable microfluidic system and a fluidic dynamic model have been successfully coupled to understand the dynamic fluid–structure interaction in transient flow, designed to understand the dentine hypersensitivity caused by hydrodynamic theory. The Polydimethylsiloxane thin sidewalls of the microfluidic chip are deformed with air pressure ranging from 50 to 500 mbar to move the liquid meniscus in the central liquid channel. The experiments show that the meniscus sharply increased in the first 10th of second and the increase is nonlinearly proportional to the applied pressure. A theoretical model is developed based on the unsteady Bernoulli equation and can well predict the ending point of the liquid displacement as well as the dynamics process, regardless of the wall thickness. Moreover, an overshooting and oscillation phenomenon is observed by reducing the head loss coefficient by a few orders which could be the key to explain the dentine hypersensitivity caused by the liquid movement in the dentine tubules.
- Open Access
- 29 September 2022
- Published by Springer Nature in Research Square
Three-Dimensional Visualization of Dentine Occlusion Based on FIB-SEM Tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- 29 September 2022
- Published by Springer Nature in Research Square
Open AccessThree-Dimensional Visualization of Dentine Occlusion Based on FIB-SEM Tomography
The occlusion of dentinal tubules has become a rapid and effective method for treating dentin hypersensitivity. Accurate evaluation of dentin occlusion is critical to illustrate the efficacy of oral care products and to optimize dental therapy in the clinics, which is limited by the conventional two-dimensional (2-D) characterization methods. Here, we demonstrate the visualization of the dentin occlusion via three-dimensional (3-D) characterization using a focused ion beam-scanning electron microscopy (FIB-SEM) tomography. Using the “Slice and View” approach, the material used for occluding dentin tubules is imaged with a very high-resolution voxel (10 nm × 10 nm × 20 nm) from 2-D SEM images and then reconstructed into a 3-D volume, which presents the mode of action of toothpaste for treating dentin hypersensitivity. Meanwhile, quantitative analysis of the depth of occlusion is successfully obtained. This work validates the feasibility of FIB-SEM tomography in the analysis of dentin occlusion within the complicated networks of dentine tubules at the nanoscale, and provides a novel approach to facilitate the research and development of oral care products.
- 14 March 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (2) , e12853
Applications of scanning electron microscopy and focused ion beam milling in dental research
The abilities of scanning electron microscopy (SEM) and focused ion beam (FIB) milling for obtaining high‐resolution images from top surfaces, cross‐sectional surfaces, and even in three dimensions, are becoming increasingly important for imaging and analyzing tooth structures such as enamel and dentin. FIB was originally developed for material research in the semiconductor industry. However, use of SEM/FIB has been growing recently in dental research due to the versatility of dual platform instruments that can be used as a milling device to obtain low‐artifact cross‐sections of samples combined with high‐resolution images. The advent of the SEM/FIB system and accessories may offer access to previously inaccessible length scales for characterizing tooth structures for dental research, opening exciting opportunities to address many central questions in dental research. New discoveries and fundamental breakthroughs in understanding are likely to follow. This review covers the applications, key findings, and future direction of SEM/FIB in dental research in morphology imaging, specimen preparation for transmission electron microscopy (TEM) analysis, and three‐dimensional volume imaging using SEM/FIB tomography.
- 14 March 2022
- Published by Wiley in European Journal of Oral Sciences
- Vol. 130 (2) , e12853
Applications of scanning electron microscopy and focused ion beam milling in dental research
The abilities of scanning electron microscopy (SEM) and focused ion beam (FIB) milling for obtaining high‐resolution images from top surfaces, cross‐sectional surfaces, and even in three dimensions, are becoming increasingly important for imaging and analyzing tooth structures such as enamel and dentin. FIB was originally developed for material research in the semiconductor industry. However, use of SEM/FIB has been growing recently in dental research due to the versatility of dual platform instruments that can be used as a milling device to obtain low‐artifact cross‐sections of samples combined with high‐resolution images. The advent of the SEM/FIB system and accessories may offer access to previously inaccessible length scales for characterizing tooth structures for dental research, opening exciting opportunities to address many central questions in dental research. New discoveries and fundamental breakthroughs in understanding are likely to follow. This review covers the applications, key findings, and future direction of SEM/FIB in dental research in morphology imaging, specimen preparation for transmission electron microscopy (TEM) analysis, and three‐dimensional volume imaging using SEM/FIB tomography.
- Open Access
- 11 February 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-8
Super high-quality SEM/FIB imaging of dentine structures without collagen fiber loss through a metal staining process
Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system has become valuable and popular tool for the analysis of biological materials such as dentine structures. According to physiological and anatomical studies, dentine structures are a complicated system containing collagen fibers, nanocrystalline hydroxyapatite, and numerous networks of tubular pores. During a routine FIB milling process, collagen fibers and other organic structures are vaporized, which increases the number of pores on the milled surface of the dentine. This causes the final cross-section to be more porous than the pristine sample. Unfortunately, little attention has been paid to the collagen fiber loss and how to preserve them during a FIB milling process. In this work, we present a novel and simple approach to preserve the organic portions of the dentine structure through metal staining. By using this method, the porosity of the dentine structure after the FIB milling process is significantly reduced similar to the pristine sample. This indicates that the organic portion of the dentine structure is well protected by the metal staining. This approach enables the SEM/FIB system to generate super-high quality SEM images with less ion beam damage; and the SEM images can better reflect the original condition of the dentine structure. Further, serial energy-dispersive X-ray spectroscopy (EDS) mapping of the stained dentine structure is achieved without an additional metal coating; and three-dimensional (3-D) elemental mapping of an occluded dentine is achieved with a significantly reduced data acquisition time.
- 11 February 2022
- Published by Springer Nature in Scientific Reports
- Vol. 12 (1) , 1-8
Open AccessSuper high-quality SEM/FIB imaging of dentine structures without collagen fiber loss through a metal staining process
Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system has become valuable and popular tool for the analysis of biological materials such as dentine structures. According to physiological and anatomical studies, dentine structures are a complicated system containing collagen fibers, nanocrystalline hydroxyapatite, and numerous networks of tubular pores. During a routine FIB milling process, collagen fibers and other organic structures are vaporized, which increases the number of pores on the milled surface of the dentine. This causes the final cross-section to be more porous than the pristine sample. Unfortunately, little attention has been paid to the collagen fiber loss and how to preserve them during a FIB milling process. In this work, we present a novel and simple approach to preserve the organic portions of the dentine structure through metal staining. By using this method, the porosity of the dentine structure after the FIB milling process is significantly reduced similar to the pristine sample. This indicates that the organic portion of the dentine structure is well protected by the metal staining. This approach enables the SEM/FIB system to generate super-high quality SEM images with less ion beam damage; and the SEM images can better reflect the original condition of the dentine structure. Further, serial energy-dispersive X-ray spectroscopy (EDS) mapping of the stained dentine structure is achieved without an additional metal coating; and three-dimensional (3-D) elemental mapping of an occluded dentine is achieved with a significantly reduced data acquisition time.
- Open Access
- 9 December 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
The integrity of synthetic magnesium silicate in charged compounds
Magnesium silicate is an inorganic compound used as an ingredient in product formulations for many different purposes. Since its compatibility with other components is critical for product quality and stability, it is essential to characterize the integrity of magnesium silicate in different solutions used for formulations. In this paper, we have determined the magnitude of dissociation of synthetic magnesium silicate in solution with positively charged, neutral, and negatively charged compounds using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), and Liquid Chromatography-High Resolution Mass Spectrometry (LC-HRMS). The EDS results were verified through Monte Carlo simulations of electron-sample interactions. The compounds chosen for this study were positively charged cetylpyridinium chloride (CPC), neutral lauryl glucoside, and negatively charged sodium cocoyl glutamate and sodium cocoyl glycinate since these are common compounds used in personal care and oral care formulations. Negatively charged compounds significantly impacted magnesium silicate dissociation, resulting in physio-chemical separation between magnesium and silicate ions. In contrast, the positively charged compound had a minor effect on dissociation due to ion competition, and the neutral compound did not have such an impact on magnesium silicate dissociation. Further, when the magnesium ions are dissociated from the synthetic magnesium silicate, the morphology is changed accordingly, and the structural integrity of the synthetic magnesium silicate is damaged. The results provide scientific confidence and guidance for product development using synthetic magnesium silicate.
- 9 December 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-11
Open AccessThe integrity of synthetic magnesium silicate in charged compounds
Magnesium silicate is an inorganic compound used as an ingredient in product formulations for many different purposes. Since its compatibility with other components is critical for product quality and stability, it is essential to characterize the integrity of magnesium silicate in different solutions used for formulations. In this paper, we have determined the magnitude of dissociation of synthetic magnesium silicate in solution with positively charged, neutral, and negatively charged compounds using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), and Liquid Chromatography-High Resolution Mass Spectrometry (LC-HRMS). The EDS results were verified through Monte Carlo simulations of electron-sample interactions. The compounds chosen for this study were positively charged cetylpyridinium chloride (CPC), neutral lauryl glucoside, and negatively charged sodium cocoyl glutamate and sodium cocoyl glycinate since these are common compounds used in personal care and oral care formulations. Negatively charged compounds significantly impacted magnesium silicate dissociation, resulting in physio-chemical separation between magnesium and silicate ions. In contrast, the positively charged compound had a minor effect on dissociation due to ion competition, and the neutral compound did not have such an impact on magnesium silicate dissociation. Further, when the magnesium ions are dissociated from the synthetic magnesium silicate, the morphology is changed accordingly, and the structural integrity of the synthetic magnesium silicate is damaged. The results provide scientific confidence and guidance for product development using synthetic magnesium silicate.
- Open Access
- 30 September 2021
- Published by Springer Nature in Research Square
The Integrity of Synthetic Magnesium Silicate in Charged Compounds
Magnesium silicate is an inorganic compound which can be used as an ingredient in product formulations for many different purposes. Since its compatibility with other ingredients is critical for product quality and stability, it is essential to characterize the integrity of magnesium silicate in different solutions used for various product formulations. In this paper, we have determined the magnitude of dissociation of synthetic magnesium silicate in positive, neutral, and negative charged compounds using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), and verified the results using Liquid Chromatography-High Resolution Mass Spectrometry (LC-HRMS). Negatively charged compounds were found to significantly impact magnesium silicate dissociation, resulting in physio-chemical separation between magnesium and silicate ions while the positively charged compound had a minor effect on dissociation due to ion competition, and the neutral compound did not have such an impact on magnesium silicate dissociation. Further, when the magnesium ions are dissociated from the synthetic magnesium silicate, the morphology is changed accordingly, and the structural integrity of the synthetic magnesium silicate is damaged. The results provide a scientific confidence and guidance for product development using the synthetic magnesium silicate.
- 30 September 2021
- Published by Springer Nature in Research Square
Open AccessThe Integrity of Synthetic Magnesium Silicate in Charged Compounds
Magnesium silicate is an inorganic compound which can be used as an ingredient in product formulations for many different purposes. Since its compatibility with other ingredients is critical for product quality and stability, it is essential to characterize the integrity of magnesium silicate in different solutions used for various product formulations. In this paper, we have determined the magnitude of dissociation of synthetic magnesium silicate in positive, neutral, and negative charged compounds using Scanning Electron Microscopy (SEM), Energy Dispersive X-ray Spectroscopy (EDS), and verified the results using Liquid Chromatography-High Resolution Mass Spectrometry (LC-HRMS). Negatively charged compounds were found to significantly impact magnesium silicate dissociation, resulting in physio-chemical separation between magnesium and silicate ions while the positively charged compound had a minor effect on dissociation due to ion competition, and the neutral compound did not have such an impact on magnesium silicate dissociation. Further, when the magnesium ions are dissociated from the synthetic magnesium silicate, the morphology is changed accordingly, and the structural integrity of the synthetic magnesium silicate is damaged. The results provide a scientific confidence and guidance for product development using the synthetic magnesium silicate.
- Open Access
- 21 July 2021
- Published by Springer Nature in Research Square
Super High-Quality SEM/FIB Imaging of Dentine Structures Without Collagen Fiber Loss Through a Metal Staining Process
Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system has become a valuable and popular tool for the analysis of biological materials such as dentine structures. According to physiological and anatomical studies, dentine structures are a complicated system containing collagen fibers, nanocrystalline hydroxyapatite, and numerous networks of tubular pores. During a routine FIB milling process, collagen fibers and other organic structures are vaporized, while the number of tubular pores remaining is increased. This causes the final cross-section to be more porous than the real sample. Unfortunately, little attention has been paid to the collagen fiber loss and how to preserve them during a FIB milling process. In this work, we present a novel and simple approach to preserve the organic portions of the dentine structure through metal staining. By using this method, the porosity of the dentine structure after the FIB milling process is significantly reduced similar to the real sample. This indicates that the organic portion of the dentine structure is well protected by the metal staining. This approach enables the SEM/FIB system to generate super-high quality SEM images with less ion beam damage; and the SEM images can better reflect the original condition of the dentine structure. Further, serial energy-dispersive X-ray spectroscopy (EDS) mapping of the stained dentine structure is achieved without an additional metal coating; and three-dimensional (3-D) elemental mapping of an occluded dentine is achieved with a significantly reduced data acquisition time.
- 21 July 2021
- Published by Springer Nature in Research Square
Open AccessSuper High-Quality SEM/FIB Imaging of Dentine Structures Without Collagen Fiber Loss Through a Metal Staining Process
Scanning Electron Microscope/Focused Ion Beam (SEM/FIB) system has become a valuable and popular tool for the analysis of biological materials such as dentine structures. According to physiological and anatomical studies, dentine structures are a complicated system containing collagen fibers, nanocrystalline hydroxyapatite, and numerous networks of tubular pores. During a routine FIB milling process, collagen fibers and other organic structures are vaporized, while the number of tubular pores remaining is increased. This causes the final cross-section to be more porous than the real sample. Unfortunately, little attention has been paid to the collagen fiber loss and how to preserve them during a FIB milling process. In this work, we present a novel and simple approach to preserve the organic portions of the dentine structure through metal staining. By using this method, the porosity of the dentine structure after the FIB milling process is significantly reduced similar to the real sample. This indicates that the organic portion of the dentine structure is well protected by the metal staining. This approach enables the SEM/FIB system to generate super-high quality SEM images with less ion beam damage; and the SEM images can better reflect the original condition of the dentine structure. Further, serial energy-dispersive X-ray spectroscopy (EDS) mapping of the stained dentine structure is achieved without an additional metal coating; and three-dimensional (3-D) elemental mapping of an occluded dentine is achieved with a significantly reduced data acquisition time.