Rachel Hilliard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rachel Hilliard has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Thomas P. Schaer
Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, USA
6 shared publications - Axel C. Moore
Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, USA
3 shared publications - Dawn M. Elliott
Department of Biomedical Engineering University of Delaware Newark Delaware USA
3 shared publications - Kyle D. Meadows
Department of Biomedical Engineering University of Delaware Newark Delaware USA
3 shared publications - Madeline S. Boyes
Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, Pennsylvania, USA
3 shared publications B. Sinder
Children’s Hospital of Philadelphia, Philadelphia, PA, United States
2 shared publications
Latest Publications
- Open Access
- 22 September 2026
- Published by Wiley in Veterinary Surgery
- Vol. 55 (8) , 1366-1374
Comparison of blind end closure techniques in equine ileum
Objective: To determine the difference in bursting pressure (BP), bursting wall tension (BWT), and closure speed between commonly utilized methods of ileal stump closure. Study design: Randomized experimental study. Sample population: A total of 71 ileal segments from 18 healthy horses. Methods: Ileum was collected postmortem from 18 horses and divided into four segments. One end of each segment was closed using one of three techniques: Parker‐Kerr (PK), gastrointestinal staples (ST), or gastrointestinal staples with a Lembert staple oversew (SO). Closure time was recorded. Control (C) segments were not altered. Segments were distended until failure. BP and infusion volume were documented, and BWT was calculated. Results: BP and BWT were higher for controls compared to all closure methods ( p < .001). No differences in BP ( p > .999) or BWT ( p > .77) were found between closure methods. ST technique was 27.1 times faster than PK ( p < .001) and 23.4 times faster than SO ( p < .001). SO was 1.2 times faster than PK ( p < .001). Mechanisms of failure were predictable within each technique. Conclusion: No difference in BP or BWT was observed between closure techniques in healthy ileum. ST and SO were significantly faster than PK. Clinical significance: The similarity in bursting strength across techniques suggests that closure method should be chosen based on other factors. The ST closure was faster compared to other techniques, and the addition of an oversewing pattern did not improve security of closure.
- 22 September 2026
- Published by Wiley in Veterinary Surgery
- Vol. 55 (8) , 1366-1374
Open AccessComparison of blind end closure techniques in equine ileum
Objective: To determine the difference in bursting pressure (BP), bursting wall tension (BWT), and closure speed between commonly utilized methods of ileal stump closure. Study design: Randomized experimental study. Sample population: A total of 71 ileal segments from 18 healthy horses. Methods: Ileum was collected postmortem from 18 horses and divided into four segments. One end of each segment was closed using one of three techniques: Parker‐Kerr (PK), gastrointestinal staples (ST), or gastrointestinal staples with a Lembert staple oversew (SO). Closure time was recorded. Control (C) segments were not altered. Segments were distended until failure. BP and infusion volume were documented, and BWT was calculated. Results: BP and BWT were higher for controls compared to all closure methods ( p < .001). No differences in BP ( p > .999) or BWT ( p > .77) were found between closure methods. ST technique was 27.1 times faster than PK ( p < .001) and 23.4 times faster than SO ( p < .001). SO was 1.2 times faster than PK ( p < .001). Mechanisms of failure were predictable within each technique. Conclusion: No difference in BP or BWT was observed between closure techniques in healthy ileum. ST and SO were significantly faster than PK. Clinical significance: The similarity in bursting strength across techniques suggests that closure method should be chosen based on other factors. The ST closure was faster compared to other techniques, and the addition of an oversewing pattern did not improve security of closure.
- Open Access
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-28
Two-phase radial endobronchial ultrasound bronchoscopy registration
PurposeLung cancer remains the leading cause of cancer death. This has brought about a critical need for managing peripheral regions of interest (ROIs) in the lungs, be it for cancer diagnosis, staging, or treatment. The state-of-the-art approach for assessing peripheral ROIs involves bronchoscopy. To perform the procedure, the physician first navigates the bronchoscope to a preplanned airway, aided by an assisted bronchoscopy system. They then confirm an ROI’s specific location and perform the requisite clinical task. Many ROIs, however, are extraluminal and invisible to the bronchoscope’s field of view. For such ROIs, current practice dictates using a supplemental imaging method, such as fluoroscopy, cone-beam computed tomography (CT), or radial endobronchial ultrasound (R-EBUS), to gather additional ROI location information. Unfortunately, fluoroscopy and cone-beam CT require substantial radiation and lengthen procedure time. As an alternative, R-EBUS is a safer real-time option involving no radiation. Regrettably, existing assisted bronchoscopy systems offer no guidance for R-EBUS confirmation, forcing the physician to resort to an unguided guess-and-check approach for R-EBUS probe placement—an approach that can produce R-EBUS placement errors exceeding 30 deg, an error that can result in missing many ROIs. Thus, because of physician skill variations, biopsy success rates using R-EBUS for ROI confirmation have varied greatly from 31% to 80%. This situation obliges the physician to turn to a radiation-based modality to gather sufficient information for ROI confirmation. We propose a two-phase registration method that provides guidance for R-EBUS probe placement.ApproachAfter the physician navigates the bronchoscope to the airway near a target ROI, the two-phase registration method begins by registering a virtual bronchoscope to the real bronchoscope. A virtual 3D R-EBUS probe model is then registered to the real R-EBUS probe shape depicted in the bronchoscopic video using an iterative region-based alignment method drawing on a level-set-based optimization. This synchronizes the guidance system to the target ROI site. The physician can now perform the R-EBUS scan to confirm the ROI.ResultsWe validated the method’s efficacy for localizing extraluminal ROIs with a series of three studies. First, for a controlled phantom study, we observed that the mean accumulated position and direction errors (accounting for both registration phases) were 1.94 mm and 3.74 deg (equivalent to 1.30 mm position error for a 20 mm biopsy needle), respectively. Next, for a live animal study, these errors were 2.81 mm and 4.79 deg (2.41 mm biopsy needle error), respectively. For 100% of the ROIs considered in these two studies, the method enabled visualization of an ROI via R-EBUS in under 3 min per ROI. Finally, initial operating-room tests on lung cancer patients indicated the method’s efficacy, functionality, efficiency, and safety under standard clinical conditions.ConclusionsThe method offers a quick, low-cost, radiation-free approach for examining peripheral extraluminal ROIs using R-EBUS. Although our studies focused on R-EBUS as the supplemental working channel instrument, the proposed method has general applicability to any clinical bronchoscopic task requiring a working channel instrument. Thus, the method has the potential to improve the efficiency and efficacy of bronchoscopic procedures for lung cancer patients.
- 1 March 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (02) , 1-28
Open AccessTwo-phase radial endobronchial ultrasound bronchoscopy registration
PurposeLung cancer remains the leading cause of cancer death. This has brought about a critical need for managing peripheral regions of interest (ROIs) in the lungs, be it for cancer diagnosis, staging, or treatment. The state-of-the-art approach for assessing peripheral ROIs involves bronchoscopy. To perform the procedure, the physician first navigates the bronchoscope to a preplanned airway, aided by an assisted bronchoscopy system. They then confirm an ROI’s specific location and perform the requisite clinical task. Many ROIs, however, are extraluminal and invisible to the bronchoscope’s field of view. For such ROIs, current practice dictates using a supplemental imaging method, such as fluoroscopy, cone-beam computed tomography (CT), or radial endobronchial ultrasound (R-EBUS), to gather additional ROI location information. Unfortunately, fluoroscopy and cone-beam CT require substantial radiation and lengthen procedure time. As an alternative, R-EBUS is a safer real-time option involving no radiation. Regrettably, existing assisted bronchoscopy systems offer no guidance for R-EBUS confirmation, forcing the physician to resort to an unguided guess-and-check approach for R-EBUS probe placement—an approach that can produce R-EBUS placement errors exceeding 30 deg, an error that can result in missing many ROIs. Thus, because of physician skill variations, biopsy success rates using R-EBUS for ROI confirmation have varied greatly from 31% to 80%. This situation obliges the physician to turn to a radiation-based modality to gather sufficient information for ROI confirmation. We propose a two-phase registration method that provides guidance for R-EBUS probe placement.ApproachAfter the physician navigates the bronchoscope to the airway near a target ROI, the two-phase registration method begins by registering a virtual bronchoscope to the real bronchoscope. A virtual 3D R-EBUS probe model is then registered to the real R-EBUS probe shape depicted in the bronchoscopic video using an iterative region-based alignment method drawing on a level-set-based optimization. This synchronizes the guidance system to the target ROI site. The physician can now perform the R-EBUS scan to confirm the ROI.ResultsWe validated the method’s efficacy for localizing extraluminal ROIs with a series of three studies. First, for a controlled phantom study, we observed that the mean accumulated position and direction errors (accounting for both registration phases) were 1.94 mm and 3.74 deg (equivalent to 1.30 mm position error for a 20 mm biopsy needle), respectively. Next, for a live animal study, these errors were 2.81 mm and 4.79 deg (2.41 mm biopsy needle error), respectively. For 100% of the ROIs considered in these two studies, the method enabled visualization of an ROI via R-EBUS in under 3 min per ROI. Finally, initial operating-room tests on lung cancer patients indicated the method’s efficacy, functionality, efficiency, and safety under standard clinical conditions.ConclusionsThe method offers a quick, low-cost, radiation-free approach for examining peripheral extraluminal ROIs using R-EBUS. Although our studies focused on R-EBUS as the supplemental working channel instrument, the proposed method has general applicability to any clinical bronchoscopic task requiring a working channel instrument. Thus, the method has the potential to improve the efficiency and efficacy of bronchoscopic procedures for lung cancer patients.
- 9 December 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 192, 128-139
Restoration of physiologic loading after engineered disc implantation mitigates immobilization-induced facet joint and paraspinal muscle degeneration
- 9 December 2024
- Published by Elsevier in Acta Biomaterialia
- Vol. 192, 128-139
Restoration of physiologic loading after engineered disc implantation mitigates immobilization-induced facet joint and paraspinal muscle degeneration
- Open Access
Can axial loading restore in vivo disc geometry, opening pressure, and T2 relaxation time?
Background: Cadaveric intervertebral discs are often studied for a variety of research questions, and outcomes are interpreted in the in vivo context. Unfortunately, the cadaveric disc does not inherently represent the LIVE condition, such that the disc structure (geometry), composition (T2 relaxation time), and mechanical function (opening pressure, OP) measured in the cadaver do not necessarily represent the in vivo disc.Methods: We conducted serial evaluations in the Yucatan minipig of disc geometry, T2 relaxation time, and OP to quantify the changes that occur with progressive dissection and used axial loading to restore the in vivo condition.Results: We found no difference in any parameter from LIVE to TORSO; thus, within 2 h of sacrifice, the TORSO disc can represent the LIVE condition. With serial dissection and sample preparation the disc height increased (SEGMENT height 18% higher than TORSO), OP decreased (POTTED was 67% lower than TORSO), and T2 time was unchanged. With axial loading, an imposed stress of 0.20–0.33 MPa returned the disc to in vivo, LIVE disc geometry and OP, although T2 time was decreased. There was a linear correlation between applied stress and OP, and this was conserved across multiple studies and species.Conclusion: To restore the LIVE disc state in human studies or other animal models, we recommend measuring the OP/stress relationship and using this relationship to select the applied stress necessary to recover the in vivo condition.
Open AccessCan axial loading restore in vivo disc geometry, opening pressure, and T2 relaxation time?
Background: Cadaveric intervertebral discs are often studied for a variety of research questions, and outcomes are interpreted in the in vivo context. Unfortunately, the cadaveric disc does not inherently represent the LIVE condition, such that the disc structure (geometry), composition (T2 relaxation time), and mechanical function (opening pressure, OP) measured in the cadaver do not necessarily represent the in vivo disc.Methods: We conducted serial evaluations in the Yucatan minipig of disc geometry, T2 relaxation time, and OP to quantify the changes that occur with progressive dissection and used axial loading to restore the in vivo condition.Results: We found no difference in any parameter from LIVE to TORSO; thus, within 2 h of sacrifice, the TORSO disc can represent the LIVE condition. With serial dissection and sample preparation the disc height increased (SEGMENT height 18% higher than TORSO), OP decreased (POTTED was 67% lower than TORSO), and T2 time was unchanged. With axial loading, an imposed stress of 0.20–0.33 MPa returned the disc to in vivo, LIVE disc geometry and OP, although T2 time was decreased. There was a linear correlation between applied stress and OP, and this was conserved across multiple studies and species.Conclusion: To restore the LIVE disc state in human studies or other animal models, we recommend measuring the OP/stress relationship and using this relationship to select the applied stress necessary to recover the in vivo condition.
- 15 November 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 15 (722) , eadf1690
Tension-activated nanofiber patches delivering an anti-inflammatory drug improve repair in a goat intervertebral disc herniation model
Conventional microdiscectomy treatment for intervertebral disc herniation alleviates pain but does not repair the annulus fibrosus, resulting in a high incidence of recurrent herniation and persistent dysfunction. The lack of repair and the acute inflammation that arise after injury can further compromise the disc and result in disc-wide degeneration in the long term. To address this clinical need, we developed tension-activated repair patches (TARPs) for annulus fibrosus repair and local delivery of the anti-inflammatory factor anakinra (a recombinant interleukin-1 receptor antagonist). TARPs transmit physiologic strain to mechanically activated microcapsules embedded within the patch, which release encapsulated bioactive molecules in direct response to spinal loading. Mechanically activated microcapsules carrying anakinra were loaded into TARPs, and the effects of TARP-mediated annular repair and anakinra delivery were evaluated in a goat model of annular injury in the cervical spine. TARPs integrated with native tissue and provided structural reinforcement at the injury site that prevented aberrant disc-wide remodeling resulting from detensioning of the annular fibrosus. The delivery of anakinra by TARP implantation increased matrix deposition and retention at the injury site and improved maintenance of disc extracellular matrix. Anakinra delivery additionally attenuated the inflammatory response associated with TARP implantation, decreasing osteolysis in adjacent vertebrae and preserving disc cellularity and matrix organization throughout the annulus fibrosus. These results demonstrate the therapeutic potential of TARPs for the treatment of intervertebral disc herniation.
- 15 November 2023
- Published by American Association for the Advancement of Science (AAAS) in Science Translational Medicine
- Vol. 15 (722) , eadf1690
Tension-activated nanofiber patches delivering an anti-inflammatory drug improve repair in a goat intervertebral disc herniation model
Conventional microdiscectomy treatment for intervertebral disc herniation alleviates pain but does not repair the annulus fibrosus, resulting in a high incidence of recurrent herniation and persistent dysfunction. The lack of repair and the acute inflammation that arise after injury can further compromise the disc and result in disc-wide degeneration in the long term. To address this clinical need, we developed tension-activated repair patches (TARPs) for annulus fibrosus repair and local delivery of the anti-inflammatory factor anakinra (a recombinant interleukin-1 receptor antagonist). TARPs transmit physiologic strain to mechanically activated microcapsules embedded within the patch, which release encapsulated bioactive molecules in direct response to spinal loading. Mechanically activated microcapsules carrying anakinra were loaded into TARPs, and the effects of TARP-mediated annular repair and anakinra delivery were evaluated in a goat model of annular injury in the cervical spine. TARPs integrated with native tissue and provided structural reinforcement at the injury site that prevented aberrant disc-wide remodeling resulting from detensioning of the annular fibrosus. The delivery of anakinra by TARP implantation increased matrix deposition and retention at the injury site and improved maintenance of disc extracellular matrix. Anakinra delivery additionally attenuated the inflammatory response associated with TARP implantation, decreasing osteolysis in adjacent vertebrae and preserving disc cellularity and matrix organization throughout the annulus fibrosus. These results demonstrate the therapeutic potential of TARPs for the treatment of intervertebral disc herniation.
- 18 July 2023
- Published by Wiley in Veterinary Surgery
- Vol. 52 (8) , 1091-1099
Repair of femoral fractures in calves via external skeletal fixator with intramedullary pin tie‐in
Objective: To describe the success rate and associated complications of external skeletal fixator/intramedullary pin tie‐in for calf femoral fracture fixation.Study Design: Clinical retrospective.Animals: Ten calves, less than 30 days old, with diaphyseal/metaphyseal femoral fractures.Methods: Medical records were reviewed from the University of Wisconsin from 2000 to 2020. Fractures were repaired using open reduction and fixation. An intramedullary Steinman pin was placed, exiting near the greater trochanter, and utilized for fracture reduction. Bicortical transfixation pins were placed distal and proximal to the fracture site. Poly(methyl methacrylate) (PMMA)‐filled tubing connected the transfixation pins and proximal intramedullary pin, creating a Type 1a external skeletal fixator (ESF) tie‐in. Follow up was obtained via medical records and phone interviews.Results: Short‐term survival rate was 7/10 (70%). Postanesthetic death occurred once. Postoperative complications occurred in all remaining cases. The most common findings were transfixation pin tract lucency and lameness (6/9 cases), implant dysfunction (5/9 cases), and infection (4/9 cases). Three of five cases with long‐term follow up survived; all went on to productive careers.Conclusion: Although patients were prone to postoperative complications, short‐term survival was comparable to previous reports.Clinical Significance: The external skeletal fixator/intramedullary (ESF/IM) pin tie‐in is less expensive and offers comparable success rates to other methods, providing a lower cost option for calf femoral fracture repair.
- 18 July 2023
- Published by Wiley in Veterinary Surgery
- Vol. 52 (8) , 1091-1099
Repair of femoral fractures in calves via external skeletal fixator with intramedullary pin tie‐in
Objective: To describe the success rate and associated complications of external skeletal fixator/intramedullary pin tie‐in for calf femoral fracture fixation.Study Design: Clinical retrospective.Animals: Ten calves, less than 30 days old, with diaphyseal/metaphyseal femoral fractures.Methods: Medical records were reviewed from the University of Wisconsin from 2000 to 2020. Fractures were repaired using open reduction and fixation. An intramedullary Steinman pin was placed, exiting near the greater trochanter, and utilized for fracture reduction. Bicortical transfixation pins were placed distal and proximal to the fracture site. Poly(methyl methacrylate) (PMMA)‐filled tubing connected the transfixation pins and proximal intramedullary pin, creating a Type 1a external skeletal fixator (ESF) tie‐in. Follow up was obtained via medical records and phone interviews.Results: Short‐term survival rate was 7/10 (70%). Postanesthetic death occurred once. Postoperative complications occurred in all remaining cases. The most common findings were transfixation pin tract lucency and lameness (6/9 cases), implant dysfunction (5/9 cases), and infection (4/9 cases). Three of five cases with long‐term follow up survived; all went on to productive careers.Conclusion: Although patients were prone to postoperative complications, short‐term survival was comparable to previous reports.Clinical Significance: The external skeletal fixator/intramedullary (ESF/IM) pin tie‐in is less expensive and offers comparable success rates to other methods, providing a lower cost option for calf femoral fracture repair.
- Open Access
- 30 May 2023
- Published by Wiley in Journal of Ultrasound in Medicine
In Vitro and In Vivo Evaluation of Ultrasound‐Triggered Release From Novel Spinal Device
Objectives-Bacterial infection following spinal fusion is a major clinical concern with up to 20% incidence. An ultrasound-triggered bulk-release system to combat postsurgical bacterial survival was designed and evaluated. Methods-Polylactic acid (PLA) clips were loaded with vancomycin (VAN) and microbubbles (Sonazoid, GE HealthCare) in vitro. Stability was determined over 14 days. VAN-loaded clips were submerged in water and insonated using a Logiq E10 scanner (GE HealthCare) with a curvilinear C6 probe. Doppler-induced VAN release was quantified using spectrophotometry. For in vivo testing, clips were loaded with methylene blue (MeB) solution and Sonazoid. These clips were implanted into a rabbit along the spine at L2 and L5, as well as a pig at L1 and L3, then insonated in Doppler mode using the C6 probe. Results-Sonazoid microbubbles were better preserved when incubated in VAN compared with distilled water at 4 degrees C, 25 degrees C, and 37 degrees C incubation temperatures (P = .0131). Contrast enhancement was observed from both solutions when incubated at 4 degrees C storage conditions. Insonated clips achieved average cumulative VAN release of 101.8 +/- 2.8% (81.4 +/- 2.8 mg) after 72 hours. Uninsonated clips had only 0.3 +/- 0.1% (0.3 +/- 0.1 mg) average cumulative VAN release (P < .0001). Clips retrieved from the rabbit did not rupture with insonation nor produce MeB staining of surrounding tissues. In the pig, the PLA film was visibly ruptured and MeB tissue was observed following insonation, whereas the uni-nsonated clip was intact. Conclusion-These results demonstrate ultrasound-triggered release of an encapsulated prophylactic solution and provide an important proof-of-concept for continuing large animal evaluations for translational merit.
- 30 May 2023
- Published by Wiley in Journal of Ultrasound in Medicine
Open AccessIn Vitro and In Vivo Evaluation of Ultrasound‐Triggered Release From Novel Spinal Device
Objectives-Bacterial infection following spinal fusion is a major clinical concern with up to 20% incidence. An ultrasound-triggered bulk-release system to combat postsurgical bacterial survival was designed and evaluated. Methods-Polylactic acid (PLA) clips were loaded with vancomycin (VAN) and microbubbles (Sonazoid, GE HealthCare) in vitro. Stability was determined over 14 days. VAN-loaded clips were submerged in water and insonated using a Logiq E10 scanner (GE HealthCare) with a curvilinear C6 probe. Doppler-induced VAN release was quantified using spectrophotometry. For in vivo testing, clips were loaded with methylene blue (MeB) solution and Sonazoid. These clips were implanted into a rabbit along the spine at L2 and L5, as well as a pig at L1 and L3, then insonated in Doppler mode using the C6 probe. Results-Sonazoid microbubbles were better preserved when incubated in VAN compared with distilled water at 4 degrees C, 25 degrees C, and 37 degrees C incubation temperatures (P = .0131). Contrast enhancement was observed from both solutions when incubated at 4 degrees C storage conditions. Insonated clips achieved average cumulative VAN release of 101.8 +/- 2.8% (81.4 +/- 2.8 mg) after 72 hours. Uninsonated clips had only 0.3 +/- 0.1% (0.3 +/- 0.1 mg) average cumulative VAN release (P < .0001). Clips retrieved from the rabbit did not rupture with insonation nor produce MeB staining of surrounding tissues. In the pig, the PLA film was visibly ruptured and MeB tissue was observed following insonation, whereas the uni-nsonated clip was intact. Conclusion-These results demonstrate ultrasound-triggered release of an encapsulated prophylactic solution and provide an important proof-of-concept for continuing large animal evaluations for translational merit.
- Open Access
- 17 April 2023
- Published by Springer Nature in Communications Biology
- Vol. 6 (1) , 1-11
Microbubble cavitation restores Staphylococcus aureus antibiotic susceptibility in vitro and in a septic arthritis model
Treatment failure in joint infections is associated with fibrinous, antibiotic-resistant, floating and tissue-associated Staphylococcus aureus aggregates formed in synovial fluid (SynF). We explore whether antibiotic activity could be increased against Staphylococcus aureus aggregates using ultrasound-triggered microbubble destruction (UTMD), in vitro and in a porcine model of septic arthritis. In vitro, when bacterially laden SynF is diluted, akin to the dilution achieved clinically with lavage and local injection of antibiotics, amikacin and ultrasound application result in increased bacterial metabolism, aggregate permeabilization, and a 4-5 log decrease in colony forming units, independent of microbubble destruction. Without SynF dilution, amikacin + UTMD does not increase antibiotic activity. Importantly, in the porcine model of septic arthritis, no bacteria are recovered from the SynF after treatment with amikacin and UTMD—ultrasound without UTMD is insufficient. Our data suggest that UTMD + antibiotics may serve as an important adjunct for the treatment of septic arthritis.
- 17 April 2023
- Published by Springer Nature in Communications Biology
- Vol. 6 (1) , 1-11
Open AccessMicrobubble cavitation restores Staphylococcus aureus antibiotic susceptibility in vitro and in a septic arthritis model
Treatment failure in joint infections is associated with fibrinous, antibiotic-resistant, floating and tissue-associated Staphylococcus aureus aggregates formed in synovial fluid (SynF). We explore whether antibiotic activity could be increased against Staphylococcus aureus aggregates using ultrasound-triggered microbubble destruction (UTMD), in vitro and in a porcine model of septic arthritis. In vitro, when bacterially laden SynF is diluted, akin to the dilution achieved clinically with lavage and local injection of antibiotics, amikacin and ultrasound application result in increased bacterial metabolism, aggregate permeabilization, and a 4-5 log decrease in colony forming units, independent of microbubble destruction. Without SynF dilution, amikacin + UTMD does not increase antibiotic activity. Importantly, in the porcine model of septic arthritis, no bacteria are recovered from the SynF after treatment with amikacin and UTMD—ultrasound without UTMD is insufficient. Our data suggest that UTMD + antibiotics may serve as an important adjunct for the treatment of septic arthritis.