R. Aleksan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
R. Aleksan has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
A. Pandey
14 Faculty of Electrical Engineering and Computing, University of Zagreb, 10000 Zagreb, Croatia
3 shared publications- A. Utrobicic
20 Ruđer Bošković Institute, 10000 Zagreb, Croatia
3 shared publications - Alexandra Kallitsopoulou
IRFU, CEA-Université Paris-Saclay, F-91191 Gif-sur-Yvette
3 shared publications - Davide Fiorina
INFN Sezione di Pavia
3 shared publications - Dimitrios Sampsonidis
Aristotle University of Thessaloniki
3 shared publications - Djunes Janssens
European Organization for Nuclear Research (CERN), 1211 Geneva 23, Switzerland
3 shared publications
Latest Publications
- Open Access
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Erratum to: Future Circular Collider Feasibility Study Report
- 21 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7)
Open AccessErratum to: Future Circular Collider Feasibility Study Report
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Design and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , P04019
Open AccessDesign and performance of a 96-channel resistive PICOSEC Micromegas detector for ENUBET
The PICOSEC-Micromegas (PICOSEC-MM) detector is a fast gaseous detector concept that achieves picosecond-level timing. It couples a Cherenkov radiator, typically an MgF 2 crystal, to a Micromegas-based photodetector equipped with a photocathode, allowing the fast photoelectron-induced signal to suppress the intrinsic time jitter characteristic of gaseous detectors. This design enables sub-20 ps timing precision while preserving the robustness and scalability of Micro-Pattern Gaseous Detector (MPGD) technologies. The 96-pad PICOSEC-MM detector represents the latest advancement in this development, optimized for precision timing in high-energy physics. Building upon the R&D insights obtained with earlier 7-pad resistive prototypes, this large-area demonstrator was developed to validate the scalability, uniformity, and robustness of the technology for integration into the ENUBET project. The detector employs a 2.5 nm Diamond-Like Carbon (DLC) photocathode with a Micromegas board equipped with surface resistivity of 10 MΩ/□, providing an excellent timing performance. The prototype was characterized using 150 GeV/ c muons at the CERN SPS beamline, with one-third of the active area instrumented during each run. A dedicated alignment procedure, developed for multi-pad PICOSEC-MM systems, was used to reconstruct the pad centers and combine measurements across different detector regions. The measured timing resolution was 43 ps across the instrumented pads, while the Signal Arrival Time (SAT) distributions exhibited a good uniformity among the detector area that was tested. Mechanical flatness was identified as a key factor influencing timing precision. Maintaining a planarity tolerance within 10 μm is therefore critical to preserve a good timing resolution over large active areas. The successful operation of the 96-pad demonstrator confirms the scalability of the PICOSEC-MM concept marking a significant step toward implementing robust, high-granularity, picosecond-level gaseous timing detectors in monitored neutrino beam experiments such as ENUBET.
- Top Cited PapersOpen Access
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Future Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- 24 December 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (12)
Top Cited PapersOpen AccessFuture Circular Collider Feasibility Study Report
Volume 1 of the FCC Feasibility Report presents an overview of the physics case, experimental programme, and detector concepts for the Future Circular Collider (FCC). This volume outlines how FCC would address some of the most profound open questions in particle physics, from precision studies of the Higgs and EW bosons and of the top quark, to the exploration of physics beyond the Standard Model. The report reviews the experimental opportunities offered by the staged implementation of FCC, beginning with an electron-positron collider (FCC-ee), operating at several centre-of-mass energies, followed by a hadron collider (FCC-hh). Benchmark examples are given of the expected physics performance, in terms of precision and sensitivity to new phenomena, of each collider stage. Detector requirements and conceptual designs for FCC-ee experiments are discussed, as are the specific demands that the physics programme imposes on the accelerator in the domains of the calibration of the collision energy, and the interface region between the accelerator and the detector. The report also highlights advances in detector, software and computing technologies, as well as the theoretical tools/reconstruction techniques that will enable the precision measurements and discovery potential of the FCC experimental programme. The content and structure of this report are guided by the scope and priorities defined in the mandate of the FCC Feasibility Study. It is therefore not intended to serve as an exhaustive review of the full physics potential of FCC. Several topics, already covered in earlier reports such as the FCC CDR, are not reiterated here or are addressed only briefly, in alignment with the study’s focus. This volume reflects the outcome of a global collaborative effort involving hundreds of scientists and institutions, aided by a dedicated community-building coordination, and provides a targeted assessment of the scientific opportunities and experimental foundations of the FCC programme.
- Open Access
- 9 January 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (1) , 1-10
Timing-based mass measurement of exotic long-lived particles at the FCC-ee
The very high luminosity run foreseen at the Z-pole for the FCC-ee will allow the detection in Z decays of new particles with very low couplings to the Standard Model. These particles can have measurable flight paths before they decay. If the timing and the position of the decay vertex can be measured with high precision, the mass of such particles can be measured by exploiting the constrained kinematics of an $$e^+e^-$$ collider. The mass resolution achievable with this technique is studied through a detailed analysis in the framework of a parametrised simulation of the performance of the IDEA detector. The adopted benchmark model is the production of Heavy Neutral Leptons, which is one of the key channels for new physics discovery at the FCC-ee.- 9 January 2025
- Published by Springer Nature in The European Physical Journal C
- Vol. 85 (1) , 1-10
Open AccessTiming-based mass measurement of exotic long-lived particles at the FCC-ee
The very high luminosity run foreseen at the Z-pole for the FCC-ee will allow the detection in Z decays of new particles with very low couplings to the Standard Model. These particles can have measurable flight paths before they decay. If the timing and the position of the decay vertex can be measured with high precision, the mass of such particles can be measured by exploiting the constrained kinematics of an $$e^+e^-$$ collider. The mass resolution achievable with this technique is studied through a detailed analysis in the framework of a parametrised simulation of the performance of the IDEA detector. The adopted benchmark model is the production of Heavy Neutral Leptons, which is one of the key channels for new physics discovery at the FCC-ee. - Open Access
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- 11 December 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1072
Open AccessPhotocathode characterisation for robust PICOSEC Micromegas precise-timing detectors
- Open Access
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
PICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
- 16 October 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1069
Open AccessPICOSEC-Micromegas Detector, an innovative solution for Lepton Time Tagging
- Open Access
- 25 March 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 105 (5) , 053008
violation and determination of the flat unitarity triangle at an FCC-eeWe investigate the sensitivity with which two angles of the flat unitarity triangle, defined by , can possibly be measured directly at FCC-ee. We show that the measured errors on the angle and should be better than 0.4° and 0.035°, respectively. These measurements, combined with the measurement of the third angle , discussed in a different paper, will contribute to probing the consistency of the sector of the Standard Model further with an unprecedented level of accuracy.- 25 March 2022
- Published by American Physical Society (APS) in Physical Review D
- Vol. 105 (5) , 053008
Open Accessviolation and determination of the flat unitarity triangle at an FCC-eeWe investigate the sensitivity with which two angles of the flat unitarity triangle, defined by , can possibly be measured directly at FCC-ee. We show that the measured errors on the angle and should be better than 0.4° and 0.035°, respectively. These measurements, combined with the measurement of the third angle , discussed in a different paper, will contribute to probing the consistency of the sector of the Standard Model further with an unprecedented level of accuracy.