AEAli Eichenberger

Ali Eichenberger

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ali Eichenberger has a total of 76 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Companion guide to the revised technical guidelines for reliable dc measurements of the quantized Hall resistance for graphene-based devices

    by Albert F Rigosi, Hansjörg Scherer, Mathieu Taupin, Luca Callegaro, Hans He, Susmit Kumar, Ali Eichenberger, Mattias Kruskopf, Yanfei Yang, Martina Marzano, et al.

    This companion guide revises and expands upon the established technical guidelines for reliable direct current measurements of the quantized Hall resistance, adapting them to the unique characteristics of epitaxial graphene. Graphene has emerged as a viable alternative to traditional Gallium Arsenide heterostructures for metrological applications due to its relaxed operating conditions. These less demanding requirements facilitate the use of low-cost, compact cryomagnet platforms, which is expected to broaden the deployment of primary resistance standards to National Metrology Institutes and other laboratories with limited resources. The guide explores the specific challenges and considerations of epitaxial graphene devices, including aspects of device choice, cooling and handling, contact resistance, conditions of quantization, and general measurements of the quantized Hall resistance. The presented details should assist those seeking to conduct rigorous characterization procedures to verify device integrity, ultimately contributing to a global effort to formally accept graphene-based devices as reliable primary resistance standards.

  • Open Access

    Cable Correction Model for HF Resistance Standards Comparisons

    by Marco Agustoni, Frédéric Overney, Ali-Laurent Eichenberger, Jan Kučera

    In this paper, we present a model that allows for significantly improving the impedance accuracy of calculable resistance standards. The proposed model extends the correction factor applied to the calculated four-terminal-pair impedance from the connector parts of the standard to the complete measurement circuit concerned by the applied voltage and current, respectively. In particular, we consider the cables and connectors contribution of the impedance bridge electronics. The model has been validated by performing: 1 : 1 and 0.1 : 1 impedance comparisons by means of two different typology of calculable resistance standards. For the measurements, we relied on the accuracy of a digital bridge, which exploits the signals of two Josephson arbitrary waveform synthesizers (JAWS). The frequency dependence of these new resistors has been analyzed over a range between 1 kHz and 80 kHz.


  • Open Access

    An International Trilateral Comparison Among the Newest Generations of Digital and Josephson Impedance Bridges

    by Massimo Ortolano, Martina Marzano, Frédéric Overney, Ali L. Eichenberger, Jan Kucera, Vincenzo D'ELia, Lucie Bartova, Juan Medved, Luca Callegaro

    This work reports and thoroughly discusses the results of an onsite trilateral comparison between a dual Josephson impedance bridge developed by METAS and the electronic fully digital impedance bridges developed by CMI and INRIMPOLITO. The target accuracies of the bridges are at the level of 10-9 to 10-8 for the former and at the level of parts in $10^{7}$ for the latter. The bridges were tested with $R\text {:}R$ and $R\text {:}C$ standards, with nominal magnitudes of $\mathrm {12.9~\text {k}\Omega }$ , and with a quantum Hall resistance standard, in conditions suitable for the primary direct realization of the impedance units ohm and farad from ac quantum Hall resistance standards or from ac/dc calculable transfer resistance standards calibrated against dc quantum Hall resistance standards. The results were fully compatible at the expected level of uncertainty for what concerns the magnitude ratio, but phase measurements with $R\text {:}C$ standards showed some incompatibilities.


  • Final report on the CCM key comparison of kilogram realizations CCM.M-K8.2021

    by M Stock, P Conceição, H Fang, F Bielsa, A Kiss, L Nielsen, F Beaudoux, P Espel, M Thomas, D Ziane, et al.

    Main text: This report describes the second CCM key comparison of realizations of the kilogram definition based on the fixed numerical value of the Planck constant, which came into force on 20 May 2019. The objectives were to determine the level of agreement between realizations of the kilogram using Kibble and joule balances and the x-ray crystal density (XRCD) method and to provide input for the calculation of the second "consensus value" of the kilogram. The consensus value serves as the basis for an internationally coordinated dissemination of the kilogram and is updated after each new key comparison. Its use will continue until satisfactory agreement between realization experiments has been achieved. Another objective was the determination of the reproducibility of the realization experiments by comparing the new results with those of the first key comparison of kilogram realizations, CCM.M-K8.2019. The comparison was organized by the BIPM and had nine participants. The BIPM, LNE, METAS, NIST, NRC and UME operated Kibble balances, the NIM used a joule balance and the NMIJ and the PTB participated using 28Si spheres, the masses of which were determined with the XRCD method. These realization methods were used to calibrate 1 kg mass standards under vacuum or in air. The standards were sent to the BIPM where they were compared with each other and with BIPM Pt-Ir working standards. The latter were calibrated traceable to the International Prototype of the Kilogram (IPK), the mass of which served as the definition of the kilogram until 20 May 2019. The results of the weighings at the BIPM together with the measurement results communicated by the participants allowed comparison of the values attributed to 1 kg mass standards using the realization experiments of the participants. The level of agreement between mass determinations with the realization experiments and the BIPM as-maintained mass unit, traceable to the Planck constant through the mass of the International Prototype of the Kilogram, could also be deduced. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • First realisation of the kilogram with the METAS Kibble balance

    by A Eichenberger, H Baumann, A Mortara, D Tommasini, D Reber, E Klingelé, B Jeanneret, B Jeckelmann

    After several years of development and continuous improvement, the Kibble balance at the Federal Institute of Metrology (METAS) is now operational. Its stability and reliability allows high precision measurements to be performed under vacuum. Two measurement campaigns were conducted in 2021 with 1 kg stainless steel test masses. The result differs from the value deduced from the calibration following the dissemination process after the redefinition of the kilogram by 6 μg with a total standard uncertainty of 43 μg (k = 1). This paper presents the details of this first result with its associated uncertainty budget.