AMAlexandre Moly

Alexandre Moly

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Alexandre Moly has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Innovative decoding algorithms for Chronic ECoG-based Brain Computer Interface (BCI) for motor disabled subjects in laboratory and at home

    by Alexandre Moly

    Une interface cerveau-machine basée sur des algorithmes de décodage innovants pour le contrôle d'effecteurs complexes en vue d'un usage au quotidien par des patients en situation de handicap moteur: Les interfaces cerveau-Machine (ICM) sont des systèmes permettant de traduire l’activité cérébrale d’un individu via un ordinateur afin d’effectuer des tâches nécessitant normalement une action des nerfs périphériques et/ou musculaires. En se basant sur l’essai clinique de CEA/LETI/CLINATEC, nommé « BCI et Tétraplégie », les recherches de thèse présentées dans ce manuscrit répondent aux challenges de l’intégration ICM dans la vie quotidienne, à savoir le contrôle complexe asynchrone d’effecteurs multi-membres et l’adaptation en temps réel des algorithmes de décodage durant des expériences en closed-loop. Pour répondre aux challenges de l’essai clinique, l’algorithme incrémental adapatif en temps réel Recursive exponentially weighted Markov switching multi-linear model (REW-MSLM) a été créé. L’algorithme REWMSLM repose sur une architecture du type Mixture d’Experts (ME). Les MEs combinent plusieurs décodeurs continus dit «experts » dont les prédictions sont pondérées par un modèle discretnommé «gate » . Les modèles des experts sont estimés via l’algorithme REW-NPLS tandis que l emodèle de gate est un modèle de markov caché (HMM). L’algorithme REW-MSLM a permis à un patient tétraplégique de contrôler un exosquelette 4 membres avec 8 degrés de liberté via ledécodage de signaux électrocorticographiques (ECoG) enregistrés avec deux implants épiduraux sans fil nommé WIMAGINE. Dans une même expérience, avec un même modèle, le patient aréalisé des tâches de contrôle alternatif des mouvements du bras gauche et du bras droit dansl’espace 3D et de rotation 1D des poignets gauche et droit. Le contrôle du patient durant ces tâches est resté très stable, même durant des expériences 6 mois après la fin de la mise à jour du modèle.Par exemple, les performances de contrôle réalisées 0 à 37 jours après la dernière mise à jour dumodèle ont montré un score de réussite de 71 ± 12% et 99 ± 2% pour les tâches de contrôle 3Ddes mouvements des mains et les tâches de contrôle 1D de rotation des poignets. Lesperformances de contrôle réalisées de 0 à 167 jours après la dernière mise à jour du modèle ontmontré un score de réussite de 67 ± 21% et 93 ± 12% pour les tâches de contrôle 3D desmouvements des mains et les tâches de contrôle 1D de rotation des poignets. Dans le but d’êtreintégré dans REW-MSLM, de nouveaux algorithmes, à savoir le (Automatic) Penalized RecursiveExponentially Weighted N-way Partial Least Squares (PREW-NPLS et APREW-NPLS) et uneversion du Modèle de Markov Caché Hiérarchique (H2M2), ont été imaginés et testés en offline.Lp-PREW-NPLS est un algorithme incrémental adaptatif permettant une pénalisation pargroupes du modèle de décodage suivant la norme/pseudo norme Lp=0, 0.5 ou 1. Pour uneutilisation en temps réel, l’algorithme PREW-NPLS nécessite de déterminer avec une étudeoffline préliminaire l’hyperparamètre de pénalisation optimal. APREW-NPLS permet de comparer en temps réel plusieurs modèles avec des hyperparamètres de pénalisation différents afin de l’optimiser en temps réel durant l’expérience. Les algorithmes PREW-NPLS et APREWNPLSont été créés pour réduire la dimension de l’espace des caractéristiques et améliorer lesperformances de décodage. H2M2, quant à lui est un classifieur dynamique similaire aux modèles de type HMM mais avec une structure hiérarchique. La structure hiérarchique est répartie encouches avec les états des couches inférieures dépendants des états des couches supérieures.L’algorithme H2M2 a été conçu dans le but d’améliorer la réactivité du modèle de classification de REW-MSLM (gating). Les résultats de décodage neural direct des signaux épiduraux ECoG obtenus nous poussent à diversifier l’utilisation de ces algorithmes à d’autres domaines.

  • Hierarchical Hidden Markov Model for Online Decoding in Brain-Computer Interface

    by Rémi Souriau, Alexandre Moly, Félix Martel, Lucas Struber, Serpil Karakas, Violaine Juillard, Guillaume Charvet, Tetiana Aksenova

    This paper presents the use of a hierarchical hidden Markov model (H2M2) for decoding brain signals from a tetraplegic patient. The H2M2 is a dynamic classifier used in this study to decode the user's motor intentions. A H2M2 consists of multiple hidden Markov models (HMM), with states organised into production states, which emit observations, and internal states, which activate sub-HMMs. The hierarchical organization of the decoder can be parameterized to represent the state to classify. A two layers and a three layers H2M2 architectures are compared with a classical HMM to decode up to seven states from ElectroCorticoGraphy (ECoG). Results show the H2M2 outperforms the HMM in term of classification performances and latency. The H2M2 presents also more stable results.


  • Open Access

    Hybrid-contours: a strategy for improving CD-SEM metrology over complex 2D patterns

    by Nivea G. Schuch, Charles Valade, Alexandre Moly, Frederic Robert, Elie Sezestre, Juline Scoarnec, Jonathan Pradelles, Loïc Perraud, Olivier Dubreuil, Thiago Figueiro

    SPIE Digital Library Proceedings


  • Open Access

    An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic

    by Alexandre Moly, Thomas Costecalde, Félix Martel, Matthieu Martin, Christelle Larzabal, Serpil Karakas, Alexandre Verney, Guillaume Charvet, Stephan Chabardes, Alim Louis Benabid, et al.

    Objective. The article aims at addressing 2 challenges to step motor brain-computer interface (BCI) out of laboratories: asynchronous control of complex bimanual effectors with large numbers of degrees of freedom, using chronic and safe recorders, and the decoding performance stability over time without frequent decoder recalibration. Approach. Closed-loop adaptive/incremental decoder training is one strategy to create a model stable over time. Adaptive decoders update their parameters with new incoming data, optimizing the model parameters in real time. It allows cross-session training with multiple recording conditions during closed loop BCI experiments. In the article, an adaptive tensor-based recursive exponentially weighted Markov-switching multi-linear model (REW-MSLM) decoder is proposed. REW-MSLM uses a mixture of expert (ME) architecture, mixing or switching independent decoders (experts) according to the probability estimated by a ‘gating’ model. A Hidden Markov model approach is employed as gating model to improve the decoding robustness and to provide strong idle state support. The ME architecture fits the multi-limb paradigm associating an expert to a particular limb or action. Main results. Asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) recorder is reported. The stable over a period of six months (without decoder recalibration) eight-dimensional alternative bimanual control of the exoskeleton and its virtual avatar is demonstrated. Significance. Based on the long-term (>36 months) chronic bilateral EpiCoG recordings in a tetraplegic (ClinicalTrials.gov, NCT02550522), we addressed the poorly explored field of asynchronous bimanual BCI. The new decoder was designed to meet to several challenges: the high-dimensional control of a complex effector in experiments closer to real-world behavior (point-to-point pursuit versus conventional center-out tasks), with the ability of the BCI system to act as a stand-alone device switching between idle and control states, and a stable performance over a long period of time without decoder recalibration.


  • Open Access

    An adaptive closed-loop ECoG decoder for long-term and stable bimanual control of an exoskeleton by a tetraplegic

    by Alexandre Moly, Thomas Costecalde, Felix Martel, Christelle Larzabal, Serpil Karakas, Alexandre Verney, Guillaume Charvet, Stephan Chabardes, Alim Louis Benabid, Tetiana Aksenova

    Brain-computer interfaces (BCIs) still face many challenges to step out of laboratories to be used in real-life applications. A key one persists in the high performance control of diverse effectors for complex tasks, using chronic and safe recorders. This control must be robust over time and of high decoding performance without continuous recalibration of the decoders. In the article, asynchronous control of an exoskeleton by a tetraplegic patient using a chronically implanted epidural electrocorticography (EpiCoG) implant is demonstrated. For this purpose, an adaptive online tensor-based decoder: the Recursive Exponentially Weighted Markov-Switching multi-Linear Model (REW-MSLM) was developed. We demonstrated over a period of 6 months the stability of the 8-dimensional alternative bimanual control of the exoskeleton and its virtual avatar using REW-MSLM without recalibration of the decoder.